Virginia Research Institute
Virginia Research Institute
Virtual Laboratory  ·  Built by E2 Innovations
← Back to Virtual Labs|Neutron Activation and the Tc-99m Generator
Nuclear Chemistry · Radionuclide Production

Neutron Activation and the Tc-99m Generator

Work as a radiochemist at a research reactor that makes radioisotopes for industry and medicine. Load targets into the reactor's irradiation position, and work out how many target atoms there are, the saturation activity, and the activity at the end of irradiation and after decay. Then run a molybdenum-99/technetium-99m generator, the source of most nuclear-medicine scans, and work out the molybdenum activity, the technetium ingrowth, the activity you will elute into the vial, and the best time to elute. Two graph work areas then plan production the way an isotope facility does: an activation curve for scheduling irradiation and cooling, and a week-long elution history for planning a generator. The parts build from undergraduate to graduate level. In every part you work out the answer yourself, then check it.

Theory: Neutron Activation and Radionuclide Generators

Why Radionuclide Production Matters

Most radioisotopes used in industry and medicine are made in research reactors by neutron activation: a stable target absorbs a neutron and becomes radioactive. Co-60 for sterilization and radiotherapy, Ir-192 for radiography, Au-198 and Na-24 for tracer studies, and Mo-99 for medical imaging are all produced this way. Mo-99 is then shipped to hospitals in generators, from which the short-lived daughter Tc-99m, used in tens of millions of scans every year, is washed off as needed. Radiochemists plan every irradiation and every elution with the equations below.

Activation: Build-Up and Saturation

During irradiation, product nuclei are made at a constant rate R = Nσφ while they also decay. The activity therefore rises towards a limit, the saturation activity, at which production equals decay. After one product half-life the activity is 50% of saturation, after two 75%, and so on, so irradiating much longer than a few half-lives gains little. After the sample is removed it simply decays.

Activation Equations N = (m/M) θ N_A   (target atoms; θ = isotopic abundance)
A_sat = N σ φ   (σ in cm², φ in n/cm²·s; A in Bq)
A_EOI = A_sat (1 − e^(−λ t_irr))     A(t_d) = A_EOI e^(−λ t_d)
Long-lived products such as Co-60 reach only a tiny fraction of saturation in a day

The Mo-99/Tc-99m Generator: Transient Equilibrium

Mo-99 (T½ = 65.94 h) is adsorbed on an alumina column. 87.6% of its decays produce Tc-99m (T½ = 6.007 h), which is chemically different and can be washed off with saline. Because the parent lives longer than the daughter but not enormously longer, the daughter grows in, passes through a maximum, and then decays in step with the parent: transient equilibrium. Elution every 24 hours, close to the maximum at about 23 hours, gives the most Tc-99m.

Transient Equilibrium (Tc-99m starting from zero after each elution) A_Mo(t) = A₀ e^(−λ_Mo t)
A_Tc(Δt) = BR × A_Mo × [λ_Tc/(λ_Tc − λ_Mo)] × (e^(−λ_Mo Δt) − e^(−λ_Tc Δt))
t_max = ln(λ_Tc/λ_Mo) / (λ_Tc − λ_Mo)     Eluted activity = η × A_Tc
BR = 0.876 · η ≈ 0.9 · t_max ≈ 23 h

Data Used in This Lab

Target → productM (g/mol)θσ (thermal, b)Product T½Use
Co-59 → Co-6058.933100%37.25.271 ySterilization, radiotherapy, gauges
Au-197 → Au-198196.967100%98.652.695 dFlux monitors, tracers
Na-23 → Na-2422.990100%0.5314.96 hLeak and flow tracing
Mo-98 → Mo-9995.95 (natural Mo)24.29%0.1365.94 hTc-99m generators

Cross sections and half-lives follow the Chart of the Nuclides (KAPL) and NNDC data. Most Mo-99 today is made by fission of U-235 targets, which gives far higher specific activity than activation of natural molybdenum; the activation route is included here to show why. Self-shielding and burn-up of the target are neglected.

Isotope production

Reactor operators schedule target positions and irradiation times to deliver the activity customers order.

Nuclear pharmacy

Radiopharmacists elute generators each morning and calculate the Tc-99m available for the day's patients.

Neutron activation analysis

Measuring induced activity identifies trace elements in forensic, geological, and environmental samples.

Production Graphs: Activation Curves and Elution Histories

An activation curve shows the product activity rising as 1 − e^(−λt) during irradiation and falling as e^(−λt) afterwards. Irradiating for one half-life reaches 50% of saturation, two half-lives 75%, and so on, so a facility weighs extra activity against reactor time. Impurities in the target are activated too, and a product is released only after short-lived impurities have decayed below a limit. An elution history follows a generator through a week: each elution removes most of the Tc-99m, the Tc-99m regrows from the decaying Mo-99, and a small fraction left on the column carries over to the next elution.

Apparatus

The equipment used to make and dispense radioisotopes. In the simulation these are modelled for you, and the readings correspond to what each would show.

Pool-type research reactor
An open-pool reactor whose core provides thermal fluxes of 10¹² to 10¹⁴ n/cm²·s at the irradiation positions.
Rabbit capsule
A polyethylene or aluminium capsule shot pneumatically into and out of the core.
Gamma counter
A calibrated NaI well counter measures the activity of the irradiated sample.
Mo-99/Tc-99m generator
An alumina column holding Mo-99, inside lead or depleted-uranium shielding.
Evacuated elution vial
Its vacuum draws saline through the column, collecting the Tc-99m pertechnetate.
37.4
Dose calibrator
An ionization chamber that measures the activity of every elution and patient dose.

Instructions: Running the Virtual Experiment

You are the radiochemist on the isotope production shift. The simulation has two immersive 3D work areas and two graph work areas. The parts build from undergraduate work in Parts A and B to graduate-level analysis in the last step of Parts C and D; the level of each part is shown beside its title. In each one you plan the run, work out the answer yourself, enter it, and press Check, then make the measurement. Record every reading and calculation in your lab report tables (modelled in the Example Report), with a labelled screenshot of each setup. Drag in any 3D view to orbit, and scroll to zoom. Use the data table in the Theory section.

Part A: Neutron Activation (3D Irradiation Facility)Undergraduate
1
Open Simulation → 3D Irradiation Facility. Choose the gold foil, m = 10 mg, φ = 1.0 × 10¹², t_irr = 24 h, and t_d = 48 h. Choose Predict: number of target atoms, calculate N, and check it.
2
Check the saturation activity, the activity at end of irradiation, and the activity after the decay time. Press Irradiate and measure and compare the gamma counter reading with your prediction. Press Record this run.
3
Repeat for cobalt (100 mg, 1.0 × 10¹³, 24 h, 0 h), sodium (50 mg, 1.0 × 10¹², 15 h, 6 h), and molybdenum (1000 mg, 1.0 × 10¹³, 72 h, 24 h). Record all runs in Table A. For each, state what fraction of saturation was reached and why.
Part B: Eluting a Tc-99m Generator (3D Tc-99m Generator)Undergraduate
1
Open 3D Tc-99m Generator. Set A₀ = 100 GBq, last elution at 48 h after calibration, and Δt = 24 h. Choose Predict: Mo-99 activity at the last elution and check it.
2
Check the Tc-99m activity on the column and the activity eluted. Press Elute into vial and compare the dose calibrator reading. Press Record this run.
3
Repeat for Δt = 6, 23, and 48 h. Check the time of maximum Tc-99m activity. Record the runs in Table B and explain why departments elute every 24 hours.
Part C: Planning Irradiation and Cooling (Graph: Activation Curve)Upper undergraduateGraduate step
1
Open Graph: Activation Curve. Choose the gold foil, 10 mg, flux 10¹², t_irr = 24 h, t_d = 48 h. Check the fraction of saturation, the activity at end of irradiation, and the activity after the decay time. Press Record this run.
2
Repeat for gold with t_irr = 72 h and t_d = 24 h; sodium (50 mg, 10¹², 15 h, 6 h); and molybdenum (1000 mg, 10¹³, 72 h, 24 h). Record every run in Table C.
3
Use the graph to explain why tripling the gold irradiation time from 24 h to 72 h less than triples the activity, and when a longer irradiation stops being worth the reactor time.
4
GraduateThe targets hold 1% sodium as an impurity. Check the cooling time until Na-24 is below 1% of the product for molybdenum (1000 mg, 10¹³, 72 h and 24 h), cobalt (100 mg, 10¹³, 24 h) and gold (10 mg, 10¹², 24 h). Record the times under Table C and explain why the gold needs none.
Part D: Planning a Generator Week (Graph: Elution History)Upper undergraduateGraduate step
1
Open Graph: Elution History. Set A₀ = 100 GBq and elute every 24 h. Check the first elution, the third elution, and the week total. Press Record this run.
2
Repeat for elution every 12 h and every 48 h. Record all three schedules in Table D.
3
From the graph, explain why eluting more often collects more Tc-99m in a week, even though each elution is smaller.
4
GraduateA department needs at least 30 GBq per elution. For each schedule, check the last elution time that still meets the need, including the 10% carry-over on the column. Record it in Table D and recommend a schedule and a delivery day for the next generator.

Simulation: Irradiation Facility, Tc-99m Generator, and Production Graphs

Activation and Generator Virtual LabSet up the equipment, work out your answer, then Check

Choose a target and load it into the irradiation position. During irradiation the product builds up towards saturation; after removal it decays. Part A uses this work area.

Drag to orbit · scroll to zoom. 3D research reactor pool: the core glows blue with Cherenkov light, and the sample capsule (rabbit) sits in the irradiation position. The capsule glows brighter as its induced activity grows, and the timeline shows irradiation and decay.

Setup

Readings

Molar mass M—
Isotopic abundance θ—
Activation cross section σ—
Product half-life—
Gamma counter: measured activity—

Use t_irr and t_d in hours and λ = ln 2 / T½ in h⁻¹. The gamma counter is calibrated to ±3%.

Work it out, then check

Table A: your activation record
Targetm (mg)φ (n/cm²·s)t_irr (h)t_d (h)NA_sat (Bq)A_EOI (Bq)A (Bq)

The generator was calibrated with a known Mo-99 activity. Tc-99m grows in from Mo-99 after each elution and is washed off with saline. Part B uses this work area.

Drag to orbit · scroll to zoom. 3D generator station: the Mo-99/Tc-99m generator column sits in its lead shield; saline is drawn through it into a shielded vial, which is measured in the dose calibrator. The board plots Mo-99 and Tc-99m activity against time since the last elution.

Setup

Readings

Mo-99 half-life—
Tc-99m half-life—
Fraction of Mo-99 decays giving Tc-99m—
Elution efficiency—
Dose calibrator reading—

The generator is fully eluted each time, so Tc-99m starts from zero at the last elution.

Work it out, then check

Table B: your generator record
A₀ Mo-99 (GBq)Last elution (h)Δt (h)A_Mo at elution (GBq)A_Tc on column (GBq)Eluted (GBq)Dose calibrator (GBq)

The activation curve shows how a product builds up toward saturation and then decays. Facilities use it to choose irradiation and cooling times. Part C uses this work area.

Product activity during irradiation (rising toward saturation) and after it (decaying), with the saturation activity dashed and the end of irradiation marked.

Show the plotted values

Setup

Readings

Product half-life—
Cross section σ—
Saturation activity—
Impurity (Advanced)—

A_EOI = A_sat(1 − e^(−λt_irr)); A = A_EOI e^(−λt_d). The Advanced step assumes the target holds 1% sodium by mass.

Work it out, then check

Table C: your activation-curve record
Targetm (mg)φt_irr (h)t_d (h)Fraction of saturation (%)A_EOI (Bq)A (Bq)

A generator is eluted on a schedule for a week before it is replaced. The elution history shows how much Tc-99m each elution delivers as the Mo-99 decays. Part D uses this work area.

One week of a fresh Mo-99/Tc-99m generator: Mo-99 activity (dashed) and Tc-99m on the column, which drops at each elution. Dots mark the activity eluted each time.

Show the plotted values

Setup

Readings

Mo-99 half-life—
Tc-99m half-life—
Branching to Tc-99m—
Elution efficiency—

The column starts with no Tc-99m at calibration (t = 0). Each elution removes 90% of the Tc-99m; 10% stays on the column.

Work it out, then check

Table D: your elution-history record
A₀ (GBq)Interval (h)First (GBq)Third (GBq)Week total (GBq)Need (GBq)Last time meeting need (h)

These immersive 3D work areas and interactive graph work areas are the main version; the accessible copy delivers the same set-up, work-out, and check exercises with native controls and screen-reader announcements.

Team Questions

Question 1. How many Co-59 atoms are in a 100 mg cobalt foil (M = 58.933 g/mol, 100% Co-59), in units of 10²¹? (e.g. 1.02)
Question 2. With σ = 37.2 b and φ = 1.0 × 10¹³ n/cm²·s, what is the saturation activity of that foil, in units of 10¹¹ Bq?
Question 3. A 10 mg gold foil (A_sat = 3.016 × 10⁹ Bq) is irradiated for 24 h. Au-198 has T½ = 2.695 d. What is the activity at the end of irradiation, in units of 10⁸ Bq?
Question 4. What is the activity of that gold foil 48 h after irradiation ends, in units of 10⁸ Bq?
Question 5. Using T½(Mo-99) = 65.94 h and T½(Tc-99m) = 6.007 h, how many hours after elution does Tc-99m activity reach its maximum?
Question 6. A generator holds 50.0 GBq of Mo-99 when it is fully eluted. How much Tc-99m is on the column 24 h later, in GBq (BR = 0.876)?
Question 7: Challenge. A generator is calibrated at 100 GBq of Mo-99 on Monday at 8 a.m. It is fully eluted at 8 a.m. on Wednesday and again at 8 a.m. on Thursday with 90% efficiency. How much Tc-99m is in Thursday's vial, in GBq?

Example Lab Report

Sample report showing the expected format and level of detail. Use it as a guide for your own submission, and include labelled screenshots of each setup. Measured activities differ from predictions by up to the ±3% (counter) or ±2% (dose calibrator) uncertainty.

Neutron Activation and the Tc-99m Generator

Nuclear Chemistry | Section: [Your Section] | Date: [Date]

Lab Members: [Names of all members present]

Purpose

To predict and measure the activity induced by neutron irradiation of gold, cobalt, sodium, and molybdenum targets; and to predict the Tc-99m activity available from a Mo-99 generator at different elution times. The lab then uses activation and elution graphs to plan production schedules, including impurity cooling and generator replacement.

Theory

The saturation activity is A_sat = Nσφ, and the activity grows as A_sat(1 − e^(−λt)) during irradiation and decays as e^(−λt) afterwards. In the generator, Tc-99m grows as BR A_Mo λ_Tc/(λ_Tc − λ_Mo)(e^(−λ_Mo t) − e^(−λ_Tc t)).

A_sat = Nσφ  ·  A_EOI = A_sat(1 − e^(−λt_irr))  ·  t_max = ln(λ_Tc/λ_Mo)/(λ_Tc − λ_Mo)

Table A: Activation Runs Undergraduate

Targetm (mg)φt_irr (h)t_d (h)NA_sat (Bq)A_EOI (Bq)A (Bq)Measured (Bq)
Au-197 → Au-1981010¹²24483.057 × 10¹⁹3.016 × 10⁹6.840 × 10⁸4.089 × 10⁸4.11 × 10⁸
Co-59 → Co-6010010¹³2401.022 × 10²¹3.801 × 10¹¹1.368 × 10⁸1.368 × 10⁸1.35 × 10⁸
Na-23 → Na-245010¹²1561.310 × 10²¹6.942 × 10⁸3.477 × 10⁸2.633 × 10⁸2.62 × 10⁸
Mo-98 → Mo-99100010¹³72241.525 × 10²¹1.982 × 10⁹1.052 × 10⁹8.175 × 10⁸8.24 × 10⁸

Sample calculation (gold): N = (0.010/196.967) × 6.022×10²³ = 3.057×10¹⁹; A_sat = 3.057×10¹⁹ × 98.65×10⁻²⁴ × 10¹² = 3.016×10⁹ Bq; λ = 0.6931/64.68 = 0.010716 h⁻¹; A_EOI = 3.016×10⁹ × (1 − e^(−0.2572)) = 6.840×10⁸ Bq; A = 6.840×10⁸ × e^(−0.5144) = 4.089×10⁸ Bq.

Table B: Generator Elutions (A₀ = 100 GBq, last elution 48 h after calibration) Undergraduate

Δt (h)A_Mo at elution (GBq)A_Tc on column (GBq)Eluted (GBq)Dose calibrator (GBq)
660.3825.5222.9623.10
2360.3841.6037.4437.21
2460.3841.5737.4137.65
4860.3834.9131.4131.30

t_max = ln(0.11539/0.010512)/(0.11539 − 0.010512) = 22.8 h.

Table C: Activation Curve Upper undergraduateGraduate step

Targetm (mg)φt_irr (h)t_d (h)Fraction of saturation (%)A_EOI (Bq)A (Bq)
Au-197 → Au-1981010¹²244822.686.840 × 10⁸4.089 × 10⁸
Au-197 → Au-1981010¹²722453.771.622 × 10⁹1.254 × 10⁹
Na-23 → Na-245010¹²15650.093.477 × 10⁸2.633 × 10⁸
Mo-98 → Mo-99100010¹³722453.091.052 × 10⁹8.175 × 10⁸

Graduate step: with 1% sodium in the target, the Na-24/product ratio at end of irradiation is 1.27 for molybdenum (72 h), 2.11 for molybdenum (24 h) and 0.68 for cobalt (24 h), so the cooling times to reach 1% are 135.3 h, 149.4 h and 91.1 h. For gold the ratio is only 0.001, so no cooling is needed.

Table D: Elution History (A₀ = 100 GBq, fresh column at calibration) Upper undergraduateGraduate step

Interval (h)First (GBq)Third (GBq)Week total (GBq)ElutionsLast time meeting 30 GBq (h)
1254.7443.78392.51460
2461.9637.71231.7772
4852.0318.98102.5396

Graduate step: following the sequence with 10% carry-over, a 30 GBq need is met until 60 h on a 12-hour schedule, 72 h on a 24-hour schedule and 96 h on a 48-hour schedule. With 24-hour elutions the department needs a new generator by day 4.

Discussion

All measured activities agreed with the predictions to within the counter uncertainty. The fraction of saturation reached depended on the irradiation time compared with the product half-life: 23% for Au-198 (24 h of a 64.7 h half-life), 50% for Na-24 (one half-life), 53% for Mo-99, but only 0.036% for Co-60, whose 5.27-year half-life means commercial Co-60 sources are irradiated for a year or more. The very low activity per gram of natural molybdenum, limited by its 0.13 b cross section and 24% Mo-98 abundance, is why most Mo-99 is made by fission instead.

Tc-99m on the generator rose quickly after elution, reaching 62% of its maximum in 6 h, peaked at 22.8 h, and then fell slowly with the Mo-99 in transient equilibrium. Eluting at 23 or 24 h gave almost exactly the maximum, which is why nuclear medicine departments elute once a day. Waiting 48 h lost 16% of the available activity, because the parent itself was decaying.

The activation graph showed the cost of chasing saturation. Tripling the gold irradiation from 24 h to 72 h raised the activity by a factor of only 2.37, because the curve flattens as it approaches A_sat. The elution graph showed the opposite trade-off for a generator: eluting every 12 h collected 392 GBq in the week against 232 GBq for daily elutions and 102 GBq for every two days, because Tc-99m left on the column decays before it can be used.

The graduate steps added the constraints a production facility and a hospital actually face. An impurity of only 1% sodium forced 91 to 149 hours of cooling for the cobalt and molybdenum targets, longer for the shorter irradiation because less of the long-lived product had built up. For the generator, the carry-over and the decay of the Mo-99 meant a 30 GBq need could only be met until day 3 to 4, which sets when the next generator must arrive.

Conclusion

Activation build-up and decay followed A_sat(1 − e^(−λt))e^(−λt_d), and generator yields followed the transient-equilibrium equation, with the best elution interval at about 23 hours.

Practice Questions

Show all work and include units. Use the data table in the Theory section.

Question 1
How long must a cobalt target be irradiated to reach 50% and 90% of its saturation activity? Comment on what this means for Co-60 source production.
Hint: 1 − e^(−λt) = 0.5 or 0.9.
Question 2
A 25 mg gold foil is used as a flux monitor. After 2.0 h at an unknown flux and a 1.0 h wait, it reads 2.5 × 10⁶ Bq. What was the thermal flux?
Hint: work backwards from A to A_EOI to A_sat, then φ = A_sat/(Nσ).
Question 3
Calculate the specific activity (Bq per gram of molybdenum) of Mo-99 from 72 h activation of natural Mo at 10¹³ n/cm²·s. Why is this too low for a modern generator?
Hint: use your Table A value at end of irradiation.
Question 4
A department needs 30 GBq of Tc-99m each morning. Using a 24 h elution interval and 90% efficiency, what Mo-99 activity must be on the column at the previous elution?
Hint: rearrange the transient-equilibrium equation for A_Mo.
Question 5
Explain the difference between transient and secular equilibrium, using Mo-99/Tc-99m and Cs-137/Ba-137m as examples.
Hint: compare the parent-to-daughter half-life ratios.
Question 6: Challenge
Mo-99 breakthrough in the eluate must stay below 0.15 kBq of Mo-99 per MBq of Tc-99m. If 0.01% of the column's Mo-99 washes through, does Thursday's elution in Team Question 7 pass?
Hint: compare 0.0001 × A_Mo at elution with the Tc-99m eluted.
© 2026 E2 Innovations LLC / Virginia Research Institute. All rights reserved. Licensed for use on E2 Innovations and VRI sites only — not for redistribution or reuse in other courses. Contact info@e2innovations.ai.