Virginia Research Institute
Virginia Research Institute
Virtual Laboratory  ·  Built by E2 Innovations
← Back to Virtual Labs|ALARA Job Planning and Shielding Design
Nuclear Engineering Technology · Radiological Protection: ALARA in Practice

ALARA Job Planning and Shielding Design

Work as a radiation protection technician planning a maintenance job in a contaminated plant room. Survey a room with three gamma sources, work out the dose rate at each work location from the inverse-square law, and plan the job: how long, how many workers, and whether a lead blanket saves more dose than it costs to install. Then design a concrete, steel, or lead shielding wall for a waste storage area so the dose rate outside meets the regulatory limit. Two graph work areas then show the ALARA trade-offs the way an RP planner sees them: collective dose against the number of lead blankets, including the dose spent installing them, and the dose-rate profile along a work route past a hot spot. In every part you work out the answer yourself, then check it.

Theory: ALARA Job Planning and Shielding Design

Why ALARA Planning Matters

Every licensee must keep radiation doses As Low As Reasonably Achievable (ALARA), as required by 10 CFR 20.1101. In a nuclear plant most dose is received during maintenance and refuelling outages, when workers must enter rooms near contaminated valves, filters, and piping. Radiation protection technicians survey the area, estimate the dose for each job, and look for ways to reduce it using the three basic tools: time, distance, and shielding. A plan is judged by its collective dose, the total for the whole crew, as well as by the dose to each individual. Shielding is only worth installing if it saves more dose than it costs to put in place.

Dose Rate from Several Point Sources

A small source behaves as a point source, so its dose rate falls with the inverse square of distance. When there are several sources, their dose rates simply add. The distance from the worker to each source comes from their positions in the room.

Inverse Square and Superposition r = √[(x_w − x_s)² + (y_w − y_s)²]
D = D₁ / r²   (D₁ = dose rate at 1 m)     D_total = Σ D₁,i / r_i²
Doubling the distance cuts the dose rate to one quarter

Time, Crew, and Collective Dose

Job Dose Individual dose H = D_total × t   (t in hours)
Collective dose S = Σ individual doses = n × H   (person-mSv)
Net saving from shielding = dose avoided by the crew − dose to install and remove it
ALARA compares options by collective dose

Good job planning moves workers to a low-dose waiting area when they are not working on the component, rehearses the job on a mock-up to shorten the time in the field, and uses remote tools or temporary shielding where they pay back.

Temporary Shielding: Lead Blankets

Lead blankets are hung over hot components to cut the dose rate before a job. Each half-value layer (HVL) halves the dose rate. For Co-60 gamma rays (1.17 and 1.33 MeV), the HVL in lead is about 1.2 cm.

Half-Value Layers D = D₀ × (1/2)^(x/HVL)
2 HVL → 1/4; 3 HVL → 1/8

Permanent Shielding Design: Tenth-Value Layers

Shielding walls for storage areas, hot cells, and waste buildings are designed with tenth-value layers (TVL): the thickness that cuts the dose rate to one tenth. Broad-beam TVLs include the build-up of scattered radiation in a thick wall, so they are more than 3.32 HVLs. The designer finds the unshielded dose rate at the occupied point, divides it by the design limit to get the attenuation factor needed, and converts that into a number of TVLs and a thickness.

TVL Shielding Design D₀ = D₁ / d²     AF = D₀ / D_limit     n = log₁₀(AF)
x = n × TVL     D = D₀ × 10^(−x/TVL)
Each TVL cuts the dose rate to one tenth

Regulatory Limits and Data Used in This Lab

Limit or area (US NRC, 10 CFR 20)Value
Occupational dose limit, total effective dose equivalent50 mSv per year (5 rem)
Unrestricted area: dose in any one hour0.02 mSv (2 mrem)
Radiation area: dose rate at 30 cm that requires postingmore than 0.05 mSv/h (5 mrem/h)
High radiation area: dose rate at 30 cmmore than 1 mSv/h (100 mrem/h)
Co-60 shielding (broad beam)HVLTVL
Lead1.2 cm4.0 cm
Steel2.1 cm7.1 cm
Ordinary concrete (2.35 g/cm³)6.2 cm20.6 cm

Limits from 10 CFR Part 20 (20.1003, 20.1201, 20.1301). Shielding values are rounded broad-beam data of the kind tabulated in NCRP Report No. 151 and the DOE Radiological Control Technician training standard. Real plans also account for extended sources, scatter, and contamination.

RP technicians

Write radiation work permits, survey work areas, and estimate job doses before every outage job.

ALARA committees

Review high-dose jobs and approve shielding, mock-up training, and remote tooling when they reduce collective dose.

Shielding engineers

Design walls for waste storage, hot cells, and medical and industrial irradiators using TVLs and design limits.

Optimizing Temporary Shielding and Work Routes

Temporary shielding is not free. Hanging and removing a lead blanket takes time in the radiation field, so it costs dose. ALARA planners compare the collective dose for different amounts of shielding, C(n) = n × I + PH × (D_v × 0.5ⁿ + D_other), and choose the number of blankets that makes C smallest. Each blanket saves half of what the previous one saved, so the savings shrink until they no longer pay for the installation. For a line of travel past a point source, the dose rate along the route is D(x) = D₁/(x² + b²), and the dose for walking past at speed v is the area under that curve divided by v, (D₁/(v b)) × 2 arctan(L/b) for a walk from −L to +L. Stopping near a hot spot is far more costly than passing it.

Apparatus

The equipment used to plan and carry out radiological work. In the simulation these are modelled for you, and the readings correspond to what each instrument would show.

2.02 mSv/h
Ion chamber survey meter
Measures gamma dose rate in mSv/h for surveys and job planning.
1.35
Electronic dosimeter
Worn by each worker; alarms at dose and dose-rate set points on the work permit.
Lead blankets
Flexible lead-wool blankets hung on hot pipes and valves as temporary shielding.
6.02.00.45
Survey map
A room plan marked with dose rates, hot spots, and the low-dose waiting area.
Shield walls
Concrete, steel, or lead walls around waste storage and hot cells, sized by tenth-value layers.
RWP
Radiation work permit
Records the survey, the dose estimate, the dosimeter set points, and the ALARA controls for the job.

Instructions: Running the Virtual Experiment

You are the radiation protection technician planning the repacking of valve V-101 and the design of a waste-storage shield wall. The simulation has two immersive 3D work areas and two graph work areas. The parts build from undergraduate work in Parts A to C to graduate-level analysis in the last step of Parts D and E; the level of each part is shown beside its title. In each one you set up the job, read the instruments, work out the answer yourself, enter it, and press Check. Record every reading and calculation in your lab report tables (modelled in the Example Report), with a labelled screenshot of each setup. Drag in any 3D view to orbit, and scroll to zoom. Use the data tables in the Theory section.

Part A: Survey the Room (3D Plant Room Survey)Undergraduate
1
Open Simulation → 3D Plant Room Survey. Choose At valve V-101 (job site) with no blanket. Choose Predict: distance from worker to valve V-101, calculate r from the positions, and check it.
2
Choose Predict: dose rate from valve V-101 and check it. Then calculate the distances to the other two sources, choose Predict: total dose rate at the worker, and check the sum. Press Survey and compare the meter reading.
3
Repeat for the Centre walkway and the Low-dose waiting area. Record the distances, dose rates, and meter readings in Table A (press Record this run). Look at the floor colours and explain why the corner is a good waiting area.
Part B: Plan the Job (3D Plant Room Survey)Undergraduate
1
Return to the job site. Set the job time to 40 min and the crew to 2. With no blanket, check the dose to each worker and the collective dose. Press Record this run.
2
Add a 1.2, 2.4, and then 3.6 cm lead blanket. For each, check the valve dose rate, the total dose rate, the individual and collective doses, and the net collective dose saved by the blanket. Record each plan in Table B.
3
Choose the plan you would put on the radiation work permit. Explain why adding more lead gives smaller and smaller savings, and what else (time, distance, waiting area) could reduce the collective dose.
Part C: Design a Shield Wall (3D Shielding Wall)Undergraduate
1
Open 3D Shielding Wall. Choose the spent resin liner, d = 4.0 m, concrete, and the 0.02 mSv/h unrestricted-area limit. Check the unshielded dose rate D₀, the attenuation factor, the number of TVLs, and the wall thickness needed.
2
Set the wall thickness slider to your answer rounded up to the next whole centimetre. Choose Predict: dose rate with the wall thickness set and check it. Press Survey outside the wall to confirm the limit is met, then press Record this run.
3
Repeat the design with steel and lead, and for the filter cask at 3.0 m with lead. Record each design in Table C and compare the thickness and practicality of each material.
Part D: Optimize the Shielding (Graph: Shielding Optimization)Upper undergraduateGraduate step
1
Open Graph: Shielding Optimization. Choose 3.0 mSv/h, 2 person-hours, and 0.2 person-mSv per blanket. Check the collective dose with no blankets, then the number of blankets that gives the lowest collective dose, then the lowest collective dose. Press Record this run.
2
Repeat for 2.0 mSv/h, 1 person-hour, 0.2 person-mSv; for 3.0 mSv/h, 2 person-hours, 0.4 person-mSv; and for 5.0 mSv/h, 4 person-hours, 0.1 person-mSv. Record each in Table D.
3
From the graph, explain why the total curve has a minimum, and why the unshielded sources set a floor. Take a labelled screenshot of one graph for your report.
4
GraduateTreat the shielding as continuous. Differentiate C(n), set dC/dn = 0, and check Advanced: optimum shielding as a continuous variable for each case in Table D. Record n* beside each row and explain how it relates to the whole-number optimum.
Part E: Plan the Route (Graph: Route Dose Profile)Upper undergraduateGraduate step
1
Open Graph: Route Dose Profile. Choose 2.0 mSv/h, offset 1.0 m, work location 0 m, speed 1.0 m/s, and limit 0.10 mSv. Check the dose rate at the work location, the stay time, and the dose for one walk through. Press Record this run.
2
Move the work location to +2 m and repeat. Then choose 6.0 mSv/h, speed 0.5 m/s, and limit 0.20 mSv, and check offset 2.0 m at +1 m and offset 1.0 m at 0 m. Record all runs in Table E.
3
Use the graph to recommend where to stage tools and where workers should wait, and compare the dose for stopping with the dose for walking through.
4
GraduateThe hot spot is really a 2.0 m length of pipe. For each run in Table E, check Advanced: dose rate if the hot spot is a 2.0 m line source, record it beside the point-source value, and state where the point model overestimates and where it underestimates.

Simulation: Plant Room Survey, Shielding Wall Design, and ALARA Graphs

ALARA Job Planning Virtual LabSet up the equipment, work out your answer, then Check

Maintenance must repack valve V-101 in a plant room with three Co-60 gamma sources. Positions are in metres from the room centre. Treat each source as a point source, and add the dose rates. Part A and Part B use this work area.

Drag to orbit · scroll to zoom. 3D plant room: a contaminated valve, a letdown filter housing, and a pipe hot spot glow red. The floor is coloured by dose rate (dark to bright orange), the worker stands at the chosen location, and lines show the distance to each source. A lead blanket wraps the valve when you add one.

Setup

Installing a blanket takes 2 workers 5 minutes each at the job site, before the blanket is in place.

Readings

Valve V-101: position; dose rate at 1 m—
Letdown filter: position; dose rate at 1 m—
Pipe hot spot: position; dose rate at 1 m—
Worker position—
Survey meter reading—

Co-60 half-value layer in lead: HVL = 1.2 cm. The survey meter reads within ±5% of the true dose rate.

Work it out, then check

Tables A and B: your survey and job plan record
LocationBlanket (cm Pb)r to valve (m)Total dose rate (mSv/h)Time (min)CrewIndividual (mSv)Collective (person-mSv)

Design the shielding wall between a waste storage bay and an occupied area. Use the tenth-value layer (TVL) method: each TVL of shielding cuts the dose rate to one tenth. Part C uses this work area.

Drag to orbit · scroll to zoom. 3D waste storage bay: a waste container behind a shielding wall whose thickness and material you choose, and a survey point in the occupied area outside. Gamma rays fan out from the container; fewer reach the survey point as the wall gets thicker.

Setup

Readings

Source strength at 1 m—
TVL of wall material (Co-60)—
Survey meter reading—
Status—

Broad-beam Co-60 TVLs: concrete 20.6 cm, steel 7.1 cm, lead 4.0 cm.

Work it out, then check

Table C: your shielding design record
Source (mSv/h at 1 m)d (m)MaterialD₀ (mSv/h)Limit (mSv/h)TVLs neededThickness needed (cm)x set (cm)Measured D (mSv/h)

Every lead blanket halves the dose rate from the valve during the job, but someone must receive dose to install and later remove it. ALARA means choosing the number of blankets that gives the lowest total collective dose. Part D uses this work area.

Collective dose for the valve job against the number of lead blankets installed: the dose spent installing blankets rises in a straight line while the job dose falls by half with each blanket, so the total has a minimum.

Show the plotted values

Setup

Readings

Each blanket—
Other sources (unshieldable)—
Model—

C(n) = n × I + PH × (D_v × 0.5ⁿ + 0.20). Simplified planning model.

Work it out, then check

Table D: your shielding-optimization record
D_v (mSv/h)Person-hoursI per blanket (person-mSv)C with 0 blanketsBest numberLowest C (person-mSv)

A walkway runs past a pipe hot spot. Workers either stop at a work location or walk straight through. The dose-rate profile shows where the dose is received and how long a worker may stay. Part E uses this work area.

Dose rate along a 10 m walkway that passes a pipe hot spot at the chosen offset. The dot marks the work location; the curve is the inverse-square profile plus background.

Show the plotted values

Setup

Readings

Distance to hot spot at the work location—
Background—
Walkway—

Point source: D(x) = D₁/(x² + b²) + background. Transit from −5 m to +5 m: dose = (D₁/(v b)) × 2 arctan(5/b)/3600 + background × (10/v)/3600.

Work it out, then check

Table E: your route record
D₁ (mSv/h)Offset b (m)Location x (m)Dose rate (mSv/h)Stay time (min)Speed (m/s)Transit dose (µSv)

These immersive 3D work areas and interactive graph work areas are the main version; the accessible copy delivers the same set-up, work-out, and check exercises with native controls and screen-reader announcements.

Team Questions

Question 1. A contaminated valve reads 6.0 mSv/h at 1 m. What is the dose rate at 2.0 m, in mSv/h?
Question 2. A 3.6 cm lead blanket (Co-60 HVL = 1.2 cm) is hung on the same valve. What is the dose rate at 1 m now, in mSv/h?
Question 3. A worker stands at (−0.5, 1.0) m and a filter housing is at (1.8, −0.8) m. How far apart are they, in metres?
Question 4. A worker spends 40 minutes in a 1.5 mSv/h field. What dose does the worker receive, in mSv?
Question 5. A job needs 2 workers for 90 minutes each in a 0.80 mSv/h field. What is the collective dose, in person-mSv?
Question 6. A waste liner reads 50 mSv/h at 1 m. The occupied area is 4.0 m away and must be below 0.02 mSv/h. How many tenth-value layers of shielding are needed?
Question 7: Challenge. Using a Co-60 TVL of 20.6 cm for concrete, how thick must the concrete wall in Question 6 be, in cm?

Example Lab Report

Sample report showing the expected format and level of detail. Use it as a guide for your own submission, and include labelled screenshots of each setup. Your survey meter readings will differ by a few percent from the calculated values.

ALARA Job Planning and Shielding Design

Nuclear Engineering Technology | Section: [Your Section] | Date: [Date]

Lab Members: [Names of all members present]

Purpose

To survey a plant room with three gamma sources using the inverse-square law and superposition; to plan a valve maintenance job by individual and collective dose, and decide whether a lead blanket is justified; to design a shielding wall for a waste storage bay using tenth-value layers; and to use graphs to find the optimum amount of temporary shielding and the stay times along a work route.

Theory

For point sources, D = D₁/r² and dose rates add. Job dose is D × t, collective dose is the sum over the crew, and a blanket attenuates by (1/2)^(x/HVL). A wall needs n = log₁₀(D₀/D_limit) TVLs, so x = n × TVL.

D = Σ D₁/r²  ·  H = D t  ·  S = nH  ·  x = TVL log₁₀(D₀/D_limit)

Table A: Room Survey (no blanket) Undergraduate

Locationr to valve (m)r to filter (m)r to pipe (m)Valve (mSv/h)Filter (mSv/h)Pipe (mSv/h)Total (mSv/h)Meter (mSv/h)
Job site (−0.5, 1.0)1.0002.9211.6646.0000.23450.28886.5236.61
Centre walkway (0.6, 0.2)2.2471.5622.2091.1880.81970.16392.1722.15
Waiting area (−3.5, −2.5)4.0315.5666.2630.36920.06460.02040.45420.447

Sample calculation (job site to filter): r = √[(−0.5 − 1.8)² + (1.0 + 0.8)²] = 2.921 m; D = 2.0/2.921² = 0.2345 mSv/h.

Table B: Job Plans at the Job Site (40 min, crew of 2) Undergraduate

Blanket (cm Pb)Total dose rate (mSv/h)Individual (mSv)Collective (person-mSv)Net saved after installation (person-mSv)
06.5234.3498.698—
1.23.5232.3494.6982.913
2.42.0231.3492.6984.913
3.61.2730.8491.6985.913

Installation dose: 2 workers × 5 min at 6.523 mSv/h = 1.087 person-mSv. Net saving with 2.4 cm = 2 × 0.667 × (6.523 − 2.023) − 1.087 = 4.913 person-mSv.

Table C: Shield Wall Designs (limit 0.02 mSv/h) Undergraduate

Sourced (m)MaterialD₀ (mSv/h)TVLs neededThickness needed (cm)x set (cm)D with wall (mSv/h)
Resin liner, 50 mSv/h4.0Concrete3.1252.19445.2460.0183
Resin liner, 50 mSv/h4.0Steel3.1252.19415.6160.0174
Resin liner, 50 mSv/h4.0Lead3.1252.1948.890.0176
Filter cask, 200 mSv/h3.0Lead22.223.04612.212.50.0167

Table D: Shielding Optimization (lead blankets, 1 HVL each) Upper undergraduateGraduate step

D_v (mSv/h)Person-hoursI per blanket (person-mSv)C with 0 blanketsBest numberLowest C (person-mSv)
210.22.2031.050
320.26.4041.575
320.46.4032.350
540.120.8071.656

C(n) = n × I + PH × (D_v × 0.5ⁿ + 0.20). Include a screenshot of one optimization graph.

Graduate step: setting dC/dn = 0 gives n* = log₂(PH·D_v·ln2/I) = 2.793, 4.378, 3.378, and 7.115 HVL for the four rows. In every case the whole-number optimum is the integer nearer n*, on whichever side has the lower cost.

Table E: Route Dose Profile (background 0.005 mSv/h) Upper undergraduateGraduate step

D₁ (mSv/h)Offset b (m)Location x (m)Dose rate (mSv/h)Stay time (min)Speed (m/s)Transit dose (µSv)
21.00.02.0053.011.54
21.02.00.40514.811.54
62.01.01.20510.00.54.00
61.00.06.0052.00.59.18

Stay times use task limits of 0.10 mSv (first two rows) and 0.20 mSv (last two rows). Transit is one walk from −5 m to +5 m.

Graduate step: treating the hot spot as a 2.0 m line source gives 1.576, 0.4686, 1.183, and 4.717 mSv/h for the four rows (point model: 2.005, 0.405, 1.205, 6.005 mSv/h).

Discussion

Valve V-101 dominated the job-site dose: 6.0 of the 6.52 mSv/h came from it, so shielding the valve was the obvious ALARA action. The waiting area in the corner was about 14 times lower than the job site, so workers should wait there whenever they are not hands-on. Survey readings agreed with the inverse-square sums to within the ±5% meter tolerance.

Without shielding, the 40-minute job would give each worker 4.3 mSv and the crew 8.7 person-mSv. A 2.4 cm blanket cut the collective dose to 2.7 person-mSv and, after paying 1.1 person-mSv to install it, saved a net 4.9 person-mSv. A 3.6 cm blanket saved only one more person-mSv, because the other two sources (0.52 mSv/h) are not shielded, so each extra HVL buys less. The recommended plan is the 2.4 or 3.6 cm blanket, depending on whether the hanger can carry the extra lead, together with a mock-up rehearsal to shorten the job.

For the waste bay, 2.19 TVLs were needed. That meant 46 cm of concrete, 16 cm of steel, or 9 cm of lead. Concrete is the cheapest and is structural, so it is normally used for permanent walls; lead is used where space is tight. The stronger filter cask needed more than three TVLs.

The optimization graph showed the ALARA trade-off directly. The job dose halves with each blanket, but the installation dose grows in a straight line, so the total has a minimum. With 3 mSv/h at the valve and 2 person-hours, the best plan was 4 blankets at 0.2 person-mSv each, but only 3 when each blanket cost 0.4 person-mSv. A bigger, longer job justified more lead (7 blankets at 5 mSv/h and 4 person-hours). The unshieldable 0.20 mSv/h from the other sources sets a floor that no amount of lead can remove. The route graph showed that dose rate falls off quickly along the walkway: moving the work location from opposite the hot spot to 2 m along it raised the stay time from 3.0 to 14.8 minutes, while a worker who walks straight past receives only about 1.5 µSv. Work should be staged away from the hot spot, and workers should not stop next to it.

The graduate steps tested the planning models. Differentiating C(n) gave the continuous optimum n*, which showed why the whole-number answers fell where they did and how the optimum grows only as the logarithm of the job dose: doubling the person-hours adds just one blanket. Modelling the hot spot as a 2.0 m pipe instead of a point lowered the dose rate directly opposite it by about 21% (2.005 to 1.576 mSv/h, and 6.005 to 4.717 mSv/h), but raised it near the end of the pipe (0.405 to 0.469 mSv/h at 2 m). Stay times set from the point model are conservative opposite the hot spot but not near its ends, so a survey along the pipe should confirm them.

Conclusion

Inverse-square superposition gave the dose rate at every work location, time and crew size gave the individual and collective doses, and a net-saving calculation justified the lead blanket. The TVL method sized a shield wall that keeps the occupied area below the 0.02 mSv/h unrestricted-area limit.

Practice Questions

Show all work and include units. Use the data tables in the Theory section.

Question 1
A worker reads 2.0 mSv/h at 1.5 m from a point source. How close can the worker stand if the dose rate must stay below 5.0 mSv/h?
Hint: D₁ = D r², then r = √(D₁/D).
Question 2
A job takes one worker 3 hours in a 0.5 mSv/h field, or three workers 1 hour each in the same field. Compare the individual and collective doses, and explain which plan is better under ALARA.
Hint: collective dose is the same; individual dose is not.
Question 3
Installing a lead blanket takes 2 workers 10 minutes at 8 mSv/h. The blanket reduces a 4-person, 2-hour job from 3.0 to 1.0 mSv/h. Is it justified? Show the net saving.
Hint: compare the collective dose avoided with the collective dose to install.
Question 4
Why is the broad-beam TVL of concrete (20.6 cm) larger than 3.32 times its HVL (6.2 cm)? What does this mean for thick walls?
Hint: think about scattered photons building up inside the wall.
Question 5
An area reads 0.8 mSv/h at 30 cm from a pipe. How must it be posted under 10 CFR 20, and how much lead (HVL 1.2 cm) would bring it below the radiation-area threshold?
Hint: compare with 0.05 and 1 mSv/h.
Question 6: Challenge
A shield wall is built from 30 cm of concrete plus a lead lining. The resin liner (50 mSv/h at 1 m) is 4.0 m from the occupied area, which must be below 0.02 mSv/h. How thick must the lead lining be?
Hint: the TVLs from each layer add: x_c/TVL_c + x_Pb/TVL_Pb = n.
© 2026 E2 Innovations LLC / Virginia Research Institute. All rights reserved. Licensed for use on E2 Innovations and VRI sites only — not for redistribution or reuse in other courses. Contact info@e2innovations.ai.