Theory: Boiling-Water and Pressurized-Water Reactors
Why Compare BWRs and PWRs?
Almost all US power reactors are light-water reactors of two kinds. A pressurized-water reactor (PWR) keeps its coolant liquid at about 15.5 MPa and makes steam in separate steam generators. A boiling-water reactor (BWR) lets the coolant boil in the core at about 7 MPa and sends the steam straight to the turbine. The difference changes how each plant is controlled, how its reactivity responds to changes, and how its heat balance works. Operators and engineers who move between the two must understand both.
Boiling, Quality, and Void Fraction
In a BWR, subcooled water enters the bottom of the core, heats to saturation, and boils. The quality x is the mass fraction of steam. The void fraction α is the volume fraction of steam, which is much larger than x because steam is about 20 times less dense than water at 7 MPa. Steam bubbles also move faster than the water, described by the slip ratio S.
Void fraction: α = 1 / [1 + ((1 − x)/x)(ρ_g/ρ_l) S]
Mixture density: ρ_m = ρ_l (1 − α) + ρ_g α
Void Feedback and Recirculation Flow Control
Steam is a poor moderator, so more void means fewer neutrons are slowed down and reactivity falls: the BWR void coefficient is strongly negative, about −100 pcm per percent void. This gives the BWR a unique way to change power. If the operators raise the recirculation flow, the water passes through the core faster, less of it boils, the void falls, and positive reactivity is added. Power rises until the extra heat makes enough steam to restore the void. With the control rods fixed, power follows the flow along a rod line, roughly in proportion.
At fixed rods: P_eq ≈ P_rated × (W / W_rated)
Heat Balances
In a PWR the core heat raises the temperature of the liquid coolant, and the hot leg must stay well below the saturation temperature: the subcooling margin. In a BWR the core heat turns feedwater into steam, so the steam flow to the turbine follows directly from the power and the enthalpy rise.
BWR: ṁ_steam = P / (h_steam − h_feedwater)
Data Used in This Lab
| Quantity | PWR | BWR |
|---|---|---|
| Rated thermal power | 3411 MWt | 3926 MWt |
| Pressure; saturation temperature | 15.5 MPa; 345 °C | 7.0 MPa; 286 °C |
| Core coolant flow | 17 600 kg/s | 13 000 kg/s |
| Cold leg / feedwater | 291.7 °C, c_p = 5.5 kJ/kg·°C | 216 °C; h_steam − h_fw = 1847 kJ/kg |
| Boiling data | — | Δh_sub = 70 kJ/kg; h_fg = 1500 kJ/kg; ρ_l = 740, ρ_g = 37 kg/m³; S = 1.5 |
| Void coefficient | — | −100 pcm per % void |
Values are typical of a four-loop Westinghouse PWR and a BWR/6, rounded for hand calculation, following the DOE Fundamentals Handbooks and the NRC Reactor Concepts Manual (PWR and BWR systems chapters). Taking the average quality as half the exit quality is a simplification.
BWR operators
Change power day to day with recirculation pumps and use rods for larger moves and shape control.
PWR operators
Watch T_avg, boron, and the subcooling margin, which is an emergency-procedure parameter.
Design
BWRs avoid steam generators but put radioactive steam in the turbine; PWRs keep it in the primary loop.
The Power–Flow Map and the Void–Quality Curve
BWR operators work from a power–flow map. With the control rods fixed, more recirculation flow sweeps steam out of the core faster, the void falls, reactivity rises, and power climbs until feedback balances it, so power follows flow along a rod line. The map is bounded by the minimum pump flow, the rated-power limit, and stability limits at high power and low flow. The void that drives this feedback depends on quality through α = 1/[1 + ((1 − x)/x)(ρ_g/ρ_l)S]. Because steam at 7 MPa is about twenty times less dense than water, a few percent quality already fills much of the channel with void.
Apparatus
The main components of the two light-water reactor types. In the simulation these are modelled for you, and the readings correspond to what the plant instruments would show.
Instructions: Running the Virtual Experiment
You are the reactor engineer comparing plant behaviour for a training brief. The simulation has two immersive 3D work areas and two graph work areas. The parts build from undergraduate work in Parts A to C to graduate-level analysis in the last step of Parts D and E; the level of each part is shown beside its title. In each one you set the plant conditions, work out the answer yourself, enter it, and press Check. Record every reading and calculation in your lab report tables (modelled in the Example Report), with a labelled screenshot of each setup. Drag in any 3D view to orbit, and scroll to zoom. Use the data table in the Theory section.
Simulation: BWR Core, Plant Heat Balance, and Operating Graphs
The BWR starts at rated conditions: 3926 MWt with 13 000 kg/s of core flow. Change the flow and the power to see how boiling, and so moderation, changes. Part A and Part B use this work area.
Setup
Readings
Average core quality is taken as half the exit quality. Void fraction: α = 1 / [1 + ((1 − x)/x)(ρ_g/ρ_l)S].
Work it out, then check
| W (%) | P (%) | P (MW) | x_e | α | ρ_m (kg/m³) | Δρ_void (pcm) | P_eq (MW) |
|---|
Choose a plant and set its power. The PWR keeps its coolant liquid at 15.5 MPa and makes steam in the steam generator; the BWR boils in the core at 7.0 MPa. Part C uses this work area.
Setup
Readings
PWR: the cold-leg temperature is held at 291.7 °C. BWR: all the core heat leaves as steam made from feedwater.
Work it out, then check
| Plant | Power (%) | Power (MW) | Flow (kg/s) | ΔT (°C) | T_hot (°C) | Subcooling (°C) | Steam flow (kg/s) |
|---|
A BWR is run from a power–flow map. With the control rods fixed, power follows core flow along a rod line. Operators raise power by raising recirculation flow, and move to a higher rod line by withdrawing rods. Part D uses this work area.
Setup
Readings
Simplified training map: P(%) = rod line × flow(%)/100, between 30% and 100% flow, with power not above 100%.
Work it out, then check
| Rod line (%) | Flow (%) | Power (%) | Power (MW) | Target (%) | Flow for target (%) |
|---|
Steam is far less dense than water, so a small steam quality fills a large part of the channel with void. The slip ratio (steam moving faster than water) lowers the void slightly. Part E uses this work area.
Setup
Readings
α = 1 / [1 + ((1 − x)/x)(ρ_g/ρ_l)S]. To find x for a target α, solve the same relation for x.
Work it out, then check
| Quality x | Void α (S = 1.5) | Void α (S = 1) | Target α | Quality for target |
|---|
This accessible version provides the same set-up, work-out, and check exercises as the 3D and graph work areas, using native controls, data tables, and screen-reader announcements.
Team Questions
Example Lab Report
Sample report showing the expected format and level of detail. Use it as a guide for your own submission, and include labelled screenshots of each setup.
BWR and PWR: Void Feedback, Flow Control, and Plant Heat Balance
Nuclear Engineering Technology | Section: [Your Section] | Date: [Date]
Lab Members: [Names of all members present]
Purpose
To calculate steam quality, void fraction, coolant density, and void reactivity in a BWR core at different flows and powers; to show how recirculation flow controls BWR power; to compare the PWR and BWR heat balances; and to read the BWR power–flow map and the void–quality curve.
Theory
Exit quality is x_e = (P/ṁ − Δh_sub)/h_fg; void follows α = 1/[1 + ((1 − x)/x)(ρ_g/ρ_l)S]; void reactivity is α_V Δα. In a PWR, ΔT = P/(ṁc_p); in a BWR, steam flow = P/Δh.
Tables A and B: BWR Core (rated void 52.78%) Undergraduate
| W (%) | P (%) | P (MW) | x_e | α | ρ_m (kg/m³) | Δρ_void (pcm) | P_eq (MW) |
|---|---|---|---|---|---|---|---|
| 100 | 100 | 3926 | 0.1547 | 0.5278 | 369.0 | 0 | 3926 |
| 90 | 100 | 3926 | 0.1770 | 0.5642 | 343.3 | −365 | 3533 |
| 105 | 100 | 3926 | 0.1451 | 0.5105 | 381.1 | +173 | 4122 |
| 80 | 80 | 3141 | 0.1547 | 0.5278 | 369.0 | 0 | 3141 |
| 60 | 60 | 2356 | 0.1547 | 0.5278 | 369.0 | 0 | 2356 |
| 100 | 70 | 2748 | 0.0943 | 0.3974 | 460.6 | +1303 | 3926 |
Sample calculation (rated): x_e = (302.0 − 70)/1500 = 0.1547; x = 0.0773; α = 1/[1 + (11.93)(0.05)(1.5)] = 0.5278; ρ_m = 740 × 0.4722 + 37 × 0.5278 = 369.0 kg/m³.
Table C: Heat Balances Undergraduate
| Plant | Power (%) | Power (MW) | Flow (kg/s) | ΔT (°C) | T_hot (°C) | Subcooling (°C) | Steam flow (kg/s) |
|---|---|---|---|---|---|---|---|
| PWR | 100 | 3411 | 17 600 | 35.24 | 326.9 | 18.1 | — |
| PWR | 100 | 3411 | 15 000 | 41.35 | 333.0 | 12.0 | — |
| PWR | 50 | 1706 | 17 600 | 17.62 | 309.3 | 35.7 | — |
| BWR | 100 | 3926 | — | — | — | — | 2126 |
| BWR | 70 | 2748 | — | — | — | — | 1488 |
Table D: Power–Flow Map Upper undergraduateGraduate step
| Rod line (%) | Flow (%) | Power (%) | Power (MW) | Target (%) | Flow for target (%) |
|---|---|---|---|---|---|
| 100 | 80 | 80.0 | 3141 | 60 | 60.0 |
| 100 | 100 | 100.0 | 3926 | 90 | 90.0 |
| 80 | 90 | 72.0 | 2827 | 60 | 75.0 |
| 80 | 100 | 80.0 | 3141 | 90 | not reachable |
| 60 | 70 | 42.0 | 1649 | 40 | 66.7 |
| 100 | 50 | 50.0 | 1963 | 45 | 45.0 |
P = rod line × flow/100; flow for a target = 100 × target/rod line, usable only between 30% and 100% flow. Include a screenshot of the map with your operating point.
Graduate step: rod line curved by power feedback, P = R(W/100)ⁿ with n = 3520/(3520 + 600) = 0.8544.
| Rod line (%) | Flow (%) | Straight rod line (%) | With power feedback (%) |
|---|---|---|---|
| 100 | 80 | 80.0 | 82.64 |
| 100 | 60 | 60.0 | 64.63 |
| 80 | 70 | 56.0 | 58.99 |
| 60 | 50 | 30.0 | 33.19 |
Table E: Void Fraction against Quality Upper undergraduateGraduate step
| Quality x | Void α (S = 1.5) | Void α (S = 1) | Target α | Quality for target |
|---|---|---|---|---|
| 0.010 | 0.1187 | 0.1681 | 0.30 | 0.0311 |
| 0.050 | 0.4124 | 0.5128 | 0.50 | 0.0698 |
| 0.100 | 0.5970 | 0.6897 | 0.60 | 0.1011 |
| 0.150 | 0.7018 | 0.7792 | 0.70 | 0.1489 |
| 0.200 | 0.7692 | 0.8333 | 0.75 | 0.1837 |
| 0.300 | 0.8511 | 0.8955 | 0.80 | 0.2308 |
α = 1/[1 + ((1 − x)/x)(0.05)(1.5)]; for a target α, x = 1/[1 + (1/α − 1)/0.075].
Graduate step: drift-flux void, α = x/{C₀[x + (1 − x)ρ_g/ρ_l] + ρ_g V_gj/G}, with C₀ = 1.13, V_gj = 0.20 m/s, G = 1800 kg/m²·s.
| Quality x | Constant slip (S = 1.5) | Drift flux |
|---|---|---|
| 0.01 | 0.1187 | 0.1402 |
| 0.05 | 0.4124 | 0.4375 |
| 0.10 | 0.5970 | 0.5954 |
| 0.20 | 0.7692 | 0.7265 |
| 0.30 | 0.8511 | 0.7840 |
Discussion
Only 15% of the coolant mass left the BWR core as steam, yet steam filled 53% of the core volume on average and 71% at the exit, halving the coolant density. Cutting flow by 10% at constant power raised the void by 3.6 percentage points and inserted −365 pcm, so the power would fall; raising flow to 105% added +173 pcm. With the rods fixed, power settled where the void returned to its rated value, which is when power is proportional to flow. Runs at 80% and 60% on the same rod line confirmed that the void, quality, and density were all unchanged. This is why BWR operators change power with the recirculation pumps.
The PWR hot leg ran 18 °C below boiling at rated conditions. Losing 15% of the coolant flow raised the core ΔT to 41 °C and cut the subcooling margin to 12 °C, showing why reactor coolant pump trips are serious events for a PWR. The BWR needed no separate steam generator: its 2126 kg/s of steam went straight to the turbine, which simplifies the plant but means the turbine handles radioactive steam.
The graphs showed the same physics as an operator sees it. On the power–flow map each rod line is a straight line through the origin, so on the 100% rod line, 80% flow gives 80% power, and a 60% target needs 60% flow. A 90% target could not be reached on the 80% rod line even at full flow: the operator must first withdraw rods to a higher rod line. The void curve rose very steeply at low quality: a quality of only 0.05 already gave 41% void, and 60% void needed a quality of about 0.10. Slip lowered the void at every quality compared with the no-slip curve, which is why void, not quality, sets the BWR moderator density.
The graduate steps showed where the simple models stop. With power feedback included, the rod line bows upward: at 60% flow on the 100% rod line the power is 64.6% rather than 60%, because the falling fuel temperature adds back reactivity as power drops. The drift-flux model gave more void than constant slip at low quality (0.4375 against 0.4124 at x = 0.05) and less at high quality (0.784 against 0.851 at x = 0.30), so a single slip ratio cannot fit the whole channel. Design codes use drift-flux correlations for this reason.
Conclusion
In the BWR, void fraction links power, flow, and reactivity, so recirculation flow controls power along a rod line. In the PWR, the coolant stays subcooled and the heat balance sets the core temperature rise and subcooling margin.
Practice Questions
Show all work and include units. Use the data table in the Theory section.