BWR and PWR: Void Feedback, Flow Control, and Plant Heat Balance

Work as a reactor engineer comparing the two light-water reactor designs. In a boiling-water reactor, change the recirculation flow and power, and work out the steam quality, the void fraction, the coolant density, the void reactivity, and the power the reactor settles at. Then run the heat balance of a pressurized-water reactor and a boiling-water reactor side by side: the core temperature rise, the subcooling margin, and the steam flow to the turbine. Two graph work areas then turn the same physics into the charts operators use: the BWR power–flow map with its rod lines and flow limits, and the curve of void fraction against steam quality. In every part you work out the answer yourself, then check it.

Theory: Boiling-Water and Pressurized-Water Reactors

Why Compare BWRs and PWRs?

Almost all US power reactors are light-water reactors of two kinds. A pressurized-water reactor (PWR) keeps its coolant liquid at about 15.5 MPa and makes steam in separate steam generators. A boiling-water reactor (BWR) lets the coolant boil in the core at about 7 MPa and sends the steam straight to the turbine. The difference changes how each plant is controlled, how its reactivity responds to changes, and how its heat balance works. Operators and engineers who move between the two must understand both.

Boiling, Quality, and Void Fraction

In a BWR, subcooled water enters the bottom of the core, heats to saturation, and boils. The quality x is the mass fraction of steam. The void fraction α is the volume fraction of steam, which is much larger than x because steam is about 20 times less dense than water at 7 MPa. Steam bubbles also move faster than the water, described by the slip ratio S.

Quality, Void, and Density Exit quality: x_e = (P/ṁ − Δh_sub) / h_fg
Void fraction: α = 1 / [1 + ((1 − x)/x)(ρ_g/ρ_l) S]
Mixture density: ρ_m = ρ_l (1 − α) + ρ_g α
A few percent steam by mass fills more than half the volume

Void Feedback and Recirculation Flow Control

Steam is a poor moderator, so more void means fewer neutrons are slowed down and reactivity falls: the BWR void coefficient is strongly negative, about −100 pcm per percent void. This gives the BWR a unique way to change power. If the operators raise the recirculation flow, the water passes through the core faster, less of it boils, the void falls, and positive reactivity is added. Power rises until the extra heat makes enough steam to restore the void. With the control rods fixed, power follows the flow along a rod line, roughly in proportion.

Void Reactivity and the Rod Line Δρ_void = α_V × (α − α_rated) × 100   (α_V = −100 pcm per % void)
At fixed rods: P_eq ≈ P_rated × (W / W_rated)
BWR: power is changed with flow · PWR: power follows turbine demand through T_avg and boron

Heat Balances

In a PWR the core heat raises the temperature of the liquid coolant, and the hot leg must stay well below the saturation temperature: the subcooling margin. In a BWR the core heat turns feedwater into steam, so the steam flow to the turbine follows directly from the power and the enthalpy rise.

Heat Balances PWR: ΔT = P / (ṁ c_p)    T_hot = T_cold + ΔT    Subcooling = T_sat − T_hot
BWR: ṁ_steam = P / (h_steam − h_feedwater)
PWR at rated: ΔT ≈ 35 °C · BWR at rated: about 2100 kg/s of steam

Data Used in This Lab

QuantityPWRBWR
Rated thermal power3411 MWt3926 MWt
Pressure; saturation temperature15.5 MPa; 345 °C7.0 MPa; 286 °C
Core coolant flow17 600 kg/s13 000 kg/s
Cold leg / feedwater291.7 °C, c_p = 5.5 kJ/kg·°C216 °C; h_steam − h_fw = 1847 kJ/kg
Boiling data—Δh_sub = 70 kJ/kg; h_fg = 1500 kJ/kg; ρ_l = 740, ρ_g = 37 kg/m³; S = 1.5
Void coefficient—−100 pcm per % void

Values are typical of a four-loop Westinghouse PWR and a BWR/6, rounded for hand calculation, following the DOE Fundamentals Handbooks and the NRC Reactor Concepts Manual (PWR and BWR systems chapters). Taking the average quality as half the exit quality is a simplification.

BWR operators

Change power day to day with recirculation pumps and use rods for larger moves and shape control.

PWR operators

Watch T_avg, boron, and the subcooling margin, which is an emergency-procedure parameter.

Design

BWRs avoid steam generators but put radioactive steam in the turbine; PWRs keep it in the primary loop.

The Power–Flow Map and the Void–Quality Curve

BWR operators work from a power–flow map. With the control rods fixed, more recirculation flow sweeps steam out of the core faster, the void falls, reactivity rises, and power climbs until feedback balances it, so power follows flow along a rod line. The map is bounded by the minimum pump flow, the rated-power limit, and stability limits at high power and low flow. The void that drives this feedback depends on quality through α = 1/[1 + ((1 − x)/x)(ρ_g/ρ_l)S]. Because steam at 7 MPa is about twenty times less dense than water, a few percent quality already fills much of the channel with void.

Apparatus

The main components of the two light-water reactor types. In the simulation these are modelled for you, and the readings correspond to what the plant instruments would show.

BWR pressure vessel
Holds the core, jet pumps, steam separators, and dryers; steam leaves from the top.
Recirculation pumps and jet pumps
Drive water through the core; changing their speed changes core flow and so power.
Pressurizer
Keeps PWR pressure at 15.5 MPa with heaters and sprays, so the core never boils.
Steam generator
U-tubes carry hot primary water; secondary water boils on the outside.
Turbine generator
Converts steam energy to electricity; in a BWR it is in the radiological area.
power vs flow map
Power–flow map
BWR operators track the plant on a power-versus-flow map with rod lines and stability limits.

Instructions: Running the Virtual Experiment

You are the reactor engineer comparing plant behaviour for a training brief. The simulation has two immersive 3D work areas and two graph work areas. The parts build from undergraduate work in Parts A to C to graduate-level analysis in the last step of Parts D and E; the level of each part is shown beside its title. In each one you set the plant conditions, work out the answer yourself, enter it, and press Check. Record every reading and calculation in your lab report tables (modelled in the Example Report), with a labelled screenshot of each setup. Drag in any 3D view to orbit, and scroll to zoom. Use the data table in the Theory section.

Part A: Quality, Void, and Density (3D BWR Core)Undergraduate
1
Open Simulation → 3D BWR Core. Set flow and power to 100%. Choose Predict: core exit quality, calculate x_e, and check it.
2
Check the average void fraction and the average coolant density. Watch the steam bubbles in the upper core. Press Record this run.
Part B: Recirculation Flow Control (3D BWR Core)Undergraduate
1
Keep power at 100% and lower the flow to 90%. Check the new void fraction and the void reactivity relative to rated, with its sign. Then raise the flow to 105% and repeat.
2
Choose Predict: equilibrium power for flows of 80% and 60%. Then set the power equal to the flow (80% and 80%, 60% and 60%) and confirm that the void returns to its rated value. Record every run in Tables A and B.
3
Set 70% power at 100% flow and check the void reactivity. Explain why a BWR operator can raise power just by raising recirculation flow.
Part C: Plant Heat Balance (3D Plant Heat Balance)Undergraduate
1
Open 3D Plant Heat Balance. Choose the PWR at 100% and 17 600 kg/s. Check the core temperature rise, the hot-leg temperature, and the subcooling margin. Press Record this run.
2
Reduce the PWR flow to 15 000 kg/s and repeat. Then set the PWR to 50% at 17 600 kg/s.
3
Choose the BWR and check the steam flow at 100% and 70%. Record all cases in Table C and compare how each plant carries its heat to the turbine.
Part D: The Power–Flow Map (Graph: Power–Flow Map)Upper undergraduateGraduate step
1
Open Graph: Power–Flow Map. Choose the 100% rod line, set the flow to 80% and the target to 60%. Check the power at this flow, the thermal power in MW, and the flow needed for the target. Press Record this run.
2
Check and record these points: 100% rod line at 100% flow (target 90%); 80% rod line at 90% flow (target 60%); 80% rod line at 100% flow (target 90%); 60% rod line at 70% flow (target 40%); 100% rod line at 50% flow (target 45%). Record all runs in Table D.
3
For the target that cannot be reached, state what the operator must do and why. Take a labelled screenshot of the map for your report.
4
GraduateReal rod lines are not straight, because power feedback (Doppler and moderator heating) opposes the void change. Choose Advanced: power on a rod line curved by power feedback and check it on the 100% rod line at 80% and 60% flow, the 80% rod line at 70% flow, and the 60% rod line at 50% flow. Record these in the graduate rows under Table D and compare them with the straight rod line.
Part E: Void Fraction against Quality (Graph: Void vs Quality)Upper undergraduateGraduate step
1
Open Graph: Void vs Quality. Set the quality to 0.10 and the target void to 0.60. Check the void fraction at this quality and the quality needed for the target void. Press Record this run.
2
Repeat for qualities 0.01, 0.05, 0.15, 0.20, and 0.30 with targets 0.30, 0.50, 0.70, 0.75, and 0.80. Read the no-slip value from the graph or the data table. Record all runs in Table E.
3
From the graph, explain why a small quality gives a large void, and how slip changes the curve.
4
GraduateThe constant-slip model ignores the uneven spread of steam across the channel. Choose Advanced: drift-flux void fraction and check it at qualities 0.01, 0.05, 0.10, 0.20, and 0.30. Record these in the graduate rows under Table E and say where the two models differ most.

Simulation: BWR Core, Plant Heat Balance, and Operating Graphs

BWR and PWR Virtual LabSet up the equipment, work out your answer, then Check

The BWR starts at rated conditions: 3926 MWt with 13 000 kg/s of core flow. Change the flow and the power to see how boiling, and so moderation, changes. Part A and Part B use this work area.

Drag to orbit · scroll to zoom. 3D boiling-water reactor: the jet pumps drive recirculation flow up through the core, where the water boils. Steam bubbles (white) fill the upper core in proportion to the void fraction and rise faster with more flow; the steam separators and dryers sit above the core.

Setup

Readings

Rated power; rated flow—
Inlet subcooling Δh_sub—
Latent heat h_fg (7.0 MPa)—
Liquid / vapour density—
Slip ratio S—
Void coefficient α_V—

Average core quality is taken as half the exit quality. Void fraction: α = 1 / [1 + ((1 − x)/x)(ρ_g/ρ_l)S].

Work it out, then check

Tables A and B: your BWR record
W (%)P (%)P (MW)x_eαρ_m (kg/m³)Δρ_void (pcm)P_eq (MW)

Choose a plant and set its power. The PWR keeps its coolant liquid at 15.5 MPa and makes steam in the steam generator; the BWR boils in the core at 7.0 MPa. Part C uses this work area.

Drag to orbit · scroll to zoom. 3D plants side by side: the PWR (left) with its pressurizer and steam generator, and the BWR (right) sending steam straight from the vessel to the turbine. The chosen plant is highlighted, and its coolant colours show the temperatures you calculate.

Setup

Readings

Pressure; saturation temperature—
Cold-leg (PWR) or feedwater (BWR) temperature—
Coolant specific heat (PWR)—
Steam enthalpy minus feedwater enthalpy (BWR)—

PWR: the cold-leg temperature is held at 291.7 °C. BWR: all the core heat leaves as steam made from feedwater.

Work it out, then check

Table C: your heat-balance record
PlantPower (%)Power (MW)Flow (kg/s)ΔT (°C)T_hot (°C)Subcooling (°C)Steam flow (kg/s)

A BWR is run from a power–flow map. With the control rods fixed, power follows core flow along a rod line. Operators raise power by raising recirculation flow, and move to a higher rod line by withdrawing rods. Part D uses this work area.

BWR power–flow map: rod lines (power proportional to core flow), the minimum pump-flow line at 30% flow, and the rated-power limit at 100%. The dot is the operating point you set.

Show the plotted values

Setup

Readings

Rated power and flow—
Rod line rule—
Minimum pump flow—
Upper limit—

Simplified training map: P(%) = rod line × flow(%)/100, between 30% and 100% flow, with power not above 100%.

Work it out, then check

Table D: your power–flow record
Rod line (%)Flow (%)Power (%)Power (MW)Target (%)Flow for target (%)

Steam is far less dense than water, so a small steam quality fills a large part of the channel with void. The slip ratio (steam moving faster than water) lowers the void slightly. Part E uses this work area.

Void fraction against steam quality at 7 MPa: the slip-ratio curve used in this lab (S = 1.5) and the no-slip curve (S = 1) for comparison. The dot is the quality you set.

Show the plotted values

Setup

Readings

Densities ρ_g / ρ_l—
Density ratio—
Slip ratio S—
Void relation—

α = 1 / [1 + ((1 − x)/x)(ρ_g/ρ_l)S]. To find x for a target α, solve the same relation for x.

Work it out, then check

Table E: your void–quality record
Quality xVoid α (S = 1.5)Void α (S = 1)Target αQuality for target

These immersive 3D work areas and interactive graph work areas are the main version; the accessible copy delivers the same set-up, work-out, and check exercises with native controls and screen-reader announcements.

Team Questions

Question 1. A BWR runs at 3926 MWt with 13 000 kg/s of core flow, 70 kJ/kg of inlet subcooling, and h_fg = 1500 kJ/kg. What is the core exit quality?
Question 2. What is the void fraction at a quality of 0.155, with ρ_g/ρ_l = 0.05 and S = 1.5?
Question 3. At a void fraction of 0.709, what is the mixture density, with ρ_l = 740 and ρ_g = 37 kg/m³?
Question 4. The void coefficient is −100 pcm per % void. Raising recirculation flow lowers the core void by 2.0%. What reactivity is added, in pcm (include the sign)?
Question 5. A PWR makes 3411 MWt with 17 600 kg/s of coolant (c_p = 5.5 kJ/kg·°C). What is the core temperature rise, in °C?
Question 6. The PWR hot leg is at 326.9 °C and the saturation temperature at 15.5 MPa is 345 °C. What is the subcooling margin, in °C?
Question 7: Challenge. A 3926 MWt BWR heats 216 °C feedwater to saturated steam, an enthalpy rise of 1847 kJ/kg. What steam flow goes to the turbine, in kg/s?

Example Lab Report

Sample report showing the expected format and level of detail. Use it as a guide for your own submission, and include labelled screenshots of each setup.

BWR and PWR: Void Feedback, Flow Control, and Plant Heat Balance

Nuclear Engineering Technology | Section: [Your Section] | Date: [Date]

Lab Members: [Names of all members present]

Purpose

To calculate steam quality, void fraction, coolant density, and void reactivity in a BWR core at different flows and powers; to show how recirculation flow controls BWR power; to compare the PWR and BWR heat balances; and to read the BWR power–flow map and the void–quality curve.

Theory

Exit quality is x_e = (P/ṁ − Δh_sub)/h_fg; void follows α = 1/[1 + ((1 − x)/x)(ρ_g/ρ_l)S]; void reactivity is α_V Δα. In a PWR, ΔT = P/(ṁc_p); in a BWR, steam flow = P/Δh.

x_e = (P/ṁ − Δh_sub)/h_fg  ·  ρ_m = ρ_l(1 − α) + ρ_gα  ·  Δρ = α_V Δα  ·  ΔT = P/(ṁc_p)

Tables A and B: BWR Core (rated void 52.78%) Undergraduate

W (%)P (%)P (MW)x_eαρ_m (kg/m³)Δρ_void (pcm)P_eq (MW)
10010039260.15470.5278369.003926
9010039260.17700.5642343.3−3653533
10510039260.14510.5105381.1+1734122
808031410.15470.5278369.003141
606023560.15470.5278369.002356
1007027480.09430.3974460.6+13033926

Sample calculation (rated): x_e = (302.0 − 70)/1500 = 0.1547; x = 0.0773; α = 1/[1 + (11.93)(0.05)(1.5)] = 0.5278; ρ_m = 740 × 0.4722 + 37 × 0.5278 = 369.0 kg/m³.

Table C: Heat Balances Undergraduate

PlantPower (%)Power (MW)Flow (kg/s)ΔT (°C)T_hot (°C)Subcooling (°C)Steam flow (kg/s)
PWR100341117 60035.24326.918.1—
PWR100341115 00041.35333.012.0—
PWR50170617 60017.62309.335.7—
BWR1003926————2126
BWR702748————1488

Table D: Power–Flow Map Upper undergraduateGraduate step

Rod line (%)Flow (%)Power (%)Power (MW)Target (%)Flow for target (%)
1008080.031416060.0
100100100.039269090.0
809072.028276075.0
8010080.0314190not reachable
607042.016494066.7
1005050.019634545.0

P = rod line × flow/100; flow for a target = 100 × target/rod line, usable only between 30% and 100% flow. Include a screenshot of the map with your operating point.

Graduate step: rod line curved by power feedback, P = R(W/100)ⁿ with n = 3520/(3520 + 600) = 0.8544.

Rod line (%)Flow (%)Straight rod line (%)With power feedback (%)
1008080.082.64
1006060.064.63
807056.058.99
605030.033.19

Table E: Void Fraction against Quality Upper undergraduateGraduate step

Quality xVoid α (S = 1.5)Void α (S = 1)Target αQuality for target
0.0100.11870.16810.300.0311
0.0500.41240.51280.500.0698
0.1000.59700.68970.600.1011
0.1500.70180.77920.700.1489
0.2000.76920.83330.750.1837
0.3000.85110.89550.800.2308

α = 1/[1 + ((1 − x)/x)(0.05)(1.5)]; for a target α, x = 1/[1 + (1/α − 1)/0.075].

Graduate step: drift-flux void, α = x/{C₀[x + (1 − x)ρ_g/ρ_l] + ρ_g V_gj/G}, with C₀ = 1.13, V_gj = 0.20 m/s, G = 1800 kg/m²·s.

Quality xConstant slip (S = 1.5)Drift flux
0.010.11870.1402
0.050.41240.4375
0.100.59700.5954
0.200.76920.7265
0.300.85110.7840

Discussion

Only 15% of the coolant mass left the BWR core as steam, yet steam filled 53% of the core volume on average and 71% at the exit, halving the coolant density. Cutting flow by 10% at constant power raised the void by 3.6 percentage points and inserted −365 pcm, so the power would fall; raising flow to 105% added +173 pcm. With the rods fixed, power settled where the void returned to its rated value, which is when power is proportional to flow. Runs at 80% and 60% on the same rod line confirmed that the void, quality, and density were all unchanged. This is why BWR operators change power with the recirculation pumps.

The PWR hot leg ran 18 °C below boiling at rated conditions. Losing 15% of the coolant flow raised the core ΔT to 41 °C and cut the subcooling margin to 12 °C, showing why reactor coolant pump trips are serious events for a PWR. The BWR needed no separate steam generator: its 2126 kg/s of steam went straight to the turbine, which simplifies the plant but means the turbine handles radioactive steam.

The graphs showed the same physics as an operator sees it. On the power–flow map each rod line is a straight line through the origin, so on the 100% rod line, 80% flow gives 80% power, and a 60% target needs 60% flow. A 90% target could not be reached on the 80% rod line even at full flow: the operator must first withdraw rods to a higher rod line. The void curve rose very steeply at low quality: a quality of only 0.05 already gave 41% void, and 60% void needed a quality of about 0.10. Slip lowered the void at every quality compared with the no-slip curve, which is why void, not quality, sets the BWR moderator density.

The graduate steps showed where the simple models stop. With power feedback included, the rod line bows upward: at 60% flow on the 100% rod line the power is 64.6% rather than 60%, because the falling fuel temperature adds back reactivity as power drops. The drift-flux model gave more void than constant slip at low quality (0.4375 against 0.4124 at x = 0.05) and less at high quality (0.784 against 0.851 at x = 0.30), so a single slip ratio cannot fit the whole channel. Design codes use drift-flux correlations for this reason.

Conclusion

In the BWR, void fraction links power, flow, and reactivity, so recirculation flow controls power along a rod line. In the PWR, the coolant stays subcooled and the heat balance sets the core temperature rise and subcooling margin.

Practice Questions

Show all work and include units. Use the data table in the Theory section.

Question 1
Calculate the exit void fraction of the BWR at rated conditions (use x = x_e). Why is the top of a BWR core less well moderated than the bottom?
Hint: compare the exit and average void.
Question 2
A BWR at 100% power has one recirculation pump trip, cutting core flow to 55%. Estimate the new equilibrium power with the rods fixed.
Hint: power follows flow along the rod line.
Question 3
Explain why the void coefficient makes a BWR self-limiting, and why low flow with high power can lead to power oscillations.
Hint: think about the delay between power changes and void changes.
Question 4
What PWR coolant flow would give a 30 °C core temperature rise at 3411 MWt?
Hint: rearrange ΔT = P/(ṁc_p).
Question 5
List three advantages and three disadvantages of a BWR compared with a PWR.
Hint: think about steam generators, pressure, turbine radiation, and control.
Question 6: Challenge
A BWR at 100% flow and 100% power must reduce to 80% power for a grid request. Describe two ways to do it and the reactivity changes involved in each.
Hint: flow along the rod line, or rod insertion at constant flow.
© 2026 E2 Innovations LLC / Virginia Research Institute. All rights reserved. Licensed for use on E2 Innovations and VRI sites only — not for redistribution or reuse in other courses. Contact info@e2innovations.ai.