Measure water quality through dissolved oxygen in four experiments: DO saturation versus temperature, percent saturation, the 5-day biochemical oxygen demand (BOD), and BOD measured with dilution. In each, predict the result yourself, then run the bench and check. Units: mg/L, percent, °C.
Theory: Dissolved Oxygen & BOD
The oxygen in water
Dissolved oxygen (DO) keeps fish and aquatic life alive. How much water can hold depends on temperature — warm water holds less. Comparing the measured DO with that saturation value gives the percent saturation, a quick gauge of water health.
Key relationships
DO saturation ≈ 14 − 0.25 × T | % saturation = (measured / saturation) × 100 | BOD₅ = DO₀ − DO₅ | Diluted BOD = (D1 − D2) / P
High BOD means microbes are using a lot of oxygen to break down pollution.
Biochemical oxygen demand
BOD measures how much oxygen microbes consume as they decompose organic matter. A sealed sample is measured on day 0 and again after 5 days; the drop is the BOD₅. High BOD signals heavy organic pollution — sewage, runoff, decaying matter.
Why dilute?
Strong wastewater would use up all the oxygen before day 5, so it is diluted first. The dilution factor then scales the measured drop back up to the true demand.
Apparatus
The elements of a dissolved-oxygen study. In the simulation these are modeled for you.
DO vs Temp
Warmer water holds less oxygen.
% Saturation
Measured DO against the maximum.
BOD Bottle
Sealed 5 days in the dark.
Dilution BOD
Dilution factor scales the demand.
Instructions
The Simulation has four experiments on tabs. In each, set the control, work out the answer yourself first, enter your prediction, and press Check. Record every run. The 3D benches can be rotated and zoomed; the graph tabs show curves.
Experiment A: DO Saturation vs Temperature
1
On the DO vs Temp tab, set the temperature. Predict DO ≈ 14 − 0.25 × T, then check.
Experiment B: Percent Saturation
2
On the % Saturation tab, set the measured DO. Predict % = (measured / 10) × 100, then check.
Experiment C: BOD₅
3
On the BOD₅ tab, set the day-5 DO. Predict BOD₅ = 9 − DO₅, then check.
Experiment D: BOD with Dilution
4
On the Dilution BOD tab, choose the dilution factor. Predict BOD = (9 − 3) × DF, then check.
Simulation
Dissolved Oxygen Virtual LabFour experiments — pick a tab, predict, then check.
Text view
A temperature. Work out DO saturation ≈ 14 − 0.25 × T, then check.
A tank of water; each bubble is dissolved oxygen. Warmer water shows fewer bubbles. Rotate to view.
DO Saturation vs Temperature
Readout
Temperature20 °C
DO saturation— hidden
Predict the DO saturation (mg/L), then check.
Text view
A measured DO out of 10. Work out the percent saturation, then check.
Percent saturation versus measured DO — a straight line to 100% at 10 mg/L. The amber line marks your reading.
Percent Saturation
Readout
Measured DO8 mg/L (sat = 10)
% saturation— hidden
Predict the percent saturation, then check.
Text view
A day-5 DO. Work out BOD₅ = 9 − DO₅, then check.
A sealed BOD bottle; bubbles show the oxygen left on day 5. Fewer bubbles means more was consumed. Rotate to view.
BOD₅
Readout
Day 09 mg/L
Day 5day 5: 3 mg/L
BOD₅— hidden
Predict the BOD₅, then check.
Text view
A dilution factor. Work out BOD = (9 − 3) × DF, then check.
Measured BOD versus dilution factor — a straight line. The amber line marks your dilution factor.
BOD with Dilution
Readout
D1 − D29 − 3 mg/L
DilutionDF = 10 (P = 0.10)
BOD— hidden
Predict the BOD, then check.
Team Questions
Question 1. (A) Using DO ≈ 14 − 0.25T, what is the saturation at 20 °C?
Question 2. (A) Does dissolved oxygen rise or fall as water warms?
Question 3. (B) A reading of 8 mg/L against a saturation of 10 mg/L is what percent?
Question 4. (B) What does a low percent saturation suggest about the water?
Question 5. (C) DO falls from 9 to 3 mg/L over 5 days. What is the BOD₅?
Question 6. (C) What does a high BOD tell you about a water sample?
Question 7. (D) BOD = (9 − 3) with a dilution factor of 10. What is the BOD?
Question 8. (D) Why is a strong wastewater sample diluted before a BOD test?
Dissolved Oxygen & BOD — Four Experiments
Biology | Section: [Your Section] | Date: [Date]
Lab Members: [Names of all members present]
Purpose
To study dissolved oxygen and oxygen demand: DO saturation versus temperature, percent saturation, the 5-day BOD, and BOD measured with dilution.
Theory
DO saturation falls with temperature (≈ 14 − 0.25T); percent saturation = (measured/saturation) × 100; BOD₅ = DO₀ − DO₅; and for strong samples BOD = (D1 − D2) / P, where P = 1/dilution factor.
Results A — DO vs Temp
Temp (°C)
DO sat (mg/L)
No rows yet.
Worked example: 14 − 0.25 × 20 = 9 mg/L.
Results B — % Saturation
Measured (mg/L)
% saturation
No rows yet.
Worked example: 8 / 10 × 100 = 80%.
Results C — BOD₅
Day-5 DO (mg/L)
BOD₅ (mg/L)
No rows yet.
Worked example: 9 − 3 = 6 mg/L.
Results D — Dilution BOD
Dilution factor
BOD (mg/L)
No rows yet.
Worked example: (9 − 3) × 10 = 60 mg/L.
Discussion
DO saturation fell steadily as temperature rose; percent saturation scaled with the measured reading; BOD₅ grew as more oxygen was consumed; and the dilution factor scaled the measured drop up to the true demand of strong wastewater.
Conclusion
Dissolved oxygen and BOD together reveal water quality. Low DO or percent saturation and high BOD point to organic pollution — the readings that regulators use to judge whether a stream can support life.
Practice Questions
1
Using DO ≈ 14 − 0.25T, find the saturation at 30 °C.
Hint: 14 − 0.25 × 30 = 6.5 mg/L.
2
A sample reads 4.5 mg/L where saturation is 9 mg/L. What is the percent saturation?
Hint: 4.5 / 9 × 100 = 50%.
3
A diluted sample (DF = 5) drops from 8 to 2 mg/L in 5 days. What is the BOD?
Hint: (8 − 2) × 5 = 30 mg/L.