Virginia Research Institute
Virginia Research Institute
Virtual Laboratory  ·  Built by E2 Innovations
← Back to Virtual Labs|Gel Electrophoresis
Cell & Molecular Biology · Gel Electrophoresis

Gel Electrophoresis

Separate and size DNA through four experiments: migration versus fragment size, the ladder standard curve, the effect of voltage, and the resolution of two fragments. In each, predict the result yourself, then run the bench and check. Units: bp, mm, V.

Theory: Gel Electrophoresis

Sorting DNA by size

Gel electrophoresis separates DNA fragments in an electric field. Because DNA is negatively charged, it migrates toward the positive electrode. The gel acts as a sieve: smaller fragments travel farther.

Key relationships Distance ≈ 80 − 18·log₁₀(size in bp)  |  Size = 10^((80 − distance)/18)  |  Distance ∝ voltage  |  Fold resolution grows with |Δlog size|
Higher agarose % resolves small fragments; lower % resolves large ones.

The standard curve

Migration distance is linear in the log of fragment size. Running a ladder of known sizes gives a standard curve from which any unknown band's size can be read.

Voltage and time

Stronger fields move DNA faster: for a given fragment and time, distance is roughly proportional to the voltage. Too high a voltage overheats the gel and smears the bands.

Resolution

Two fragments separate well when their sizes differ enough on a log scale. Choosing the right agarose concentration tunes which size range is best resolved.

Apparatus

The elements of a gel run. In the simulation these are modeled for you.

Gel Box
Wells at the top; DNA migrates downward.
Standard Curve
log(size) is linear in migration distance.
V
Power Supply
Sets the voltage that drives migration.
Resolution
Two fragments appear as separate bands.

Instructions

The Simulation has four experiments on tabs. In each, set the control, work out the answer yourself first, enter your prediction, and press Check. Record every run. The 3D gel benches can be rotated and zoomed; the analysis tabs show graphs.

Experiment A: Migration vs Size
1
On the Migration tab, set the fragment size. Predict the migration distance = 80 − 18·log₁₀(size), then check.
Experiment B: Standard Curve & Unknown
2
On the Standard Curve tab, set an unknown's migration distance. Predict its size = 10^((80 − distance)/18), then check.
Experiment C: Voltage Effect
3
On the Voltage tab, set the voltage. Predict the migration distance ≈ 0.2 × V, then check.
Experiment D: Two-Fragment Separation
4
On the Resolution tab, choose two fragment sizes. Predict the separation between their bands, then check.

Simulation

Gel Electrophoresis Virtual LabFour experiments — pick a tab, predict, then check.
The green band migrates from the wells (top, negative) toward the red positive electrode (bottom). Smaller fragments travel farther.

Migration vs Size

Readout
Fragment size1000 bp
Migration distance— hidden
Predict the migration distance, then check.

Team Questions

Question 1. (A) Toward which electrode does DNA migrate, and why?
Question 2. (A) Which travel farther through the gel — smaller or larger fragments?
Question 3. (B) What quantity is plotted linearly against migration distance?
Question 4. (B) A band migrated 26 mm. Roughly what is its size (from the standard curve)?
Question 5. (C) If you double the voltage (same run time), what happens to the migration distance?
Question 6. (C) What is the migration distance at 100 V (0.2 mm/V, 30 min)?
Question 7. (D) To resolve two small fragments of similar size, should you use a higher or lower agarose percentage?
Question 8. (D) What is the band separation between a 100 bp and a 1000 bp fragment?

Gel Electrophoresis — Four Experiments

Biology | Section: [Your Section] | Date: [Date]

Lab Members: [Names of all members present]

Purpose

To separate and size DNA through four experiments: migration versus fragment size, the ladder standard curve, the effect of voltage, and the resolution of two fragments.

Theory

DNA migrates toward the anode; distance ≈ 80 − 18·log₁₀(size), so log(size) is linear in distance. Migration distance is proportional to voltage, and two fragments resolve when their sizes differ enough on a log scale.

Results A — Migration vs Size

Size (bp)Distance (mm)
No rows yet.

Worked example: 80 − 18·log₁₀(1000) = 80 − 54 = 26 mm.

Results B — Standard Curve

Distance (mm)Size (bp)
No rows yet.

Worked example: 10^((80 − 26)/18) = 10³ = 1000 bp.

Results C — Voltage

Voltage (V)Distance (mm)
No rows yet.

Worked example: 0.2 × 100 = 20 mm; 0.2 × 200 = 40 mm.

Results D — Resolution

Fragment 1 (bp)Fragment 2 (bp)Separation (mm)
No rows yet.

Worked example: 100 bp (44 mm) vs 1000 bp (26 mm) → 18 mm apart.

Discussion

Migration distance fell with the log of fragment size; the standard curve let unknowns be sized; distance scaled linearly with voltage; and bands separated by the difference in their migration, widening as the sizes diverged.

Conclusion

Gel electrophoresis sizes DNA by charge-driven sieving. A ladder's standard curve turns a migration distance into a fragment size, and voltage and agarose settings tune the speed and resolution of the separation.

Practice Questions

1
Predict the migration distances for 500 bp and 2000 bp fragments, and the gap between them.
Hint: 80 − 18·log₁₀(500) ≈ 31 mm; 80 − 18·log₁₀(2000) ≈ 21 mm; gap ≈ 10 mm.
2
An unknown band migrated 44 mm. Use the standard curve to estimate its size.
Hint: 10^((80 − 44)/18) = 10² = 100 bp.
3
You need to distinguish 200 bp from 250 bp fragments. Would you choose 0.8% or 2% agarose, and why?
Hint: 2% — a higher-percentage gel has smaller pores that resolve small fragments and their tiny size differences.
© 2026 E2 Innovations LLC / Virginia Research Institute. All rights reserved. Licensed for use on E2 Innovations and VRI sites only — not for redistribution or reuse in other courses. Contact info@e2innovations.ai.