Investigate how the body holds its internal environment steady through four experiments: a single negative-feedback correction, the return to the set-point over time, the effect of loop gain on stability, and the resetting of the set-point in a fever. In each, predict the result yourself, then run the bench and check. Temperatures are in °C.
Theory: Homeostasis and Negative Feedback
Keeping conditions steady
Homeostasis is the maintenance of a stable internal environment despite changes outside. The body holds variables such as temperature, blood glucose, and pH within narrow ranges around a set-point.
The negative feedback loop
Most homeostasis works by negative feedback, which has three parts: a receptor (detects the change), a control center (compares it with the set-point — for temperature, the hypothalamus), and an effector (carries out the correction). The response opposes the change, pushing the variable back toward the set-point.
One correction step
V₁ = V₀ + k(set-point − V₀) | over n cycles: V(n) = set-point + (V₀ − set-point)(1 − k)ⁿ
k is the correction gain. Each cycle removes a fraction k of the remaining error.
Gain and stability
A low gain corrects slowly but smoothly. A gain near 1 corrects in about one step. A gain above 1 overshoots the set-point and oscillates; too high a gain is unstable. Real control systems are tuned to return quickly without large oscillations.
Thermoregulation and fever
When body temperature rises, effectors sweat and vasodilate to lose heat; when it falls, the body shivers and vasoconstricts to make and keep heat. In a fever the hypothalamic set-point is raised, so the body feels cold and warms itself up to the new, higher target.
Apparatus
The elements of a feedback loop. In the simulation these are modeled for you.
Set-Point
The target value the system defends.
Feedback Loop
Receptor → control center → effector.
Return to Set-Point
The variable converges back to target.
Overshoot
Too high a gain makes it oscillate.
Instructions
The Simulation has four experiments on tabs. In each, set the control, work out the answer yourself first, enter your prediction, and press Check. Record every run. The thermometer benches can be rotated and zoomed; the others show the variable over time.
Experiment A: Negative Feedback (one correction)
1
On the Feedback tab, set a disturbed body temperature and a correction gain. Predict the temperature after one correction with V₁ = V₀ + k(37 − V₀), then check.
Experiment B: Return to Set-Point over Time
2
On the Over Time tab, set the starting temperature and a number of cycles. Predict V(n) = 37 + (V₀ − 37)·0.6ⁿ, then check and watch the curve approach 37 °C.
Experiment C: Gain & Stability
3
On the Gain tab, set the loop gain. Predict the temperature after one cycle with V₁ = 37 + 5(1 − k), then check. Compare smooth approach (low gain) with oscillation (gain above 1).
Experiment D: Fever (set-point reset)
4
On the Fever tab, raise the set-point. Predict the temperature after one correction with V₁ = 37 + 0.5(set-point − 37), then check.
Simulation
Homeostasis Virtual LabFour experiments — pick a tab, predict, then check.
Text view
A body at a disturbed temperature. Work out the temperature after one negative-feedback correction, then check.
The red column is body temperature; the green mark is the 37 °C set-point. On Check the column moves toward the set-point.
Negative Feedback
Readout
Temperature40.0 °C
Gain k0.50
Set-point37 °C
After correction— hidden
Predict the body temperature after one correction, then check.
Text view
A body returning to its set-point. Work out the temperature after a number of cycles, then check.
Temperature by correction cycle. The green line is the 37 °C set-point; the amber line marks your chosen cycle.
Return Over Time
Readout
Start40.0 °C
Cyclecycle 3
Temperature— hidden
Predict the temperature after this many correction cycles, then check.
Text view
A feedback loop at a chosen gain. Work out the temperature after one cycle, then check.
The response for your chosen gain. Low gain approaches the set-point smoothly; gain above 1 overshoots and oscillates.
Gain & Stability
Readout
Gain k0.50
BehaviourSmooth approach
After 1 cycle— hidden
Predict the temperature after ONE correction cycle, then check.
Text view
A fever that resets the set-point. Work out the temperature after one correction, then check.
The green mark is the raised (fever) set-point; the red column is body temperature climbing toward it.
Fever (set-point reset)
Readout
New set-point39.0 °C
After correction— hidden
Predict the body temperature after one correction toward the new set-point, then check.
Team Questions
Question 1. (A) What kind of feedback returns a variable toward its set-point?
Question 2. (A) With V₀ = 40 °C and k = 0.5, what is the temperature after one correction?
Question 3. (B) As the number of correction cycles increases, the temperature approaches what value?
Question 4. (C) What happens to the response when the loop gain is greater than 1?
Question 5. Which brain structure acts as the control center for body-temperature regulation?
Question 6. In a feedback loop, what is the component that carries out the corrective response called?
Question 7. (D) During a fever, is the hypothalamic set-point raised or lowered?
Homeostasis and Negative Feedback — Four Experiments
Biology | Section: [Your Section] | Date: [Date]
Lab Members: [Names of all members present]
Purpose
To investigate how negative feedback maintains homeostasis: single-step correction, the return to set-point over time, the effect of loop gain on stability, and the resetting of the set-point in a fever.
Theory
Negative feedback (receptor, control center, effector) opposes departures from a set-point. One step moves the variable by V₁ = V₀ + k(SP − V₀); over cycles it converges as V(n) = SP + (V₀ − SP)(1 − k)ⁿ. High gain causes overshoot and oscillation; a fever raises the set-point.
Results A — Negative Feedback
Start (°C)
Gain k
After (°C)
No rows yet.
Worked example: 40 + 0.5(37 − 40) = 38.5 °C.
Results B — Return Over Time
Start (°C)
Cycles
Temp (°C)
No rows yet.
Worked example: 37 + (40 − 37)·0.6³ = 37.65 °C after 3 cycles.
Results C — Gain & Stability
Gain k
After 1 cycle (°C)
Behaviour
No rows yet.
Worked example: k = 1.4 → 37 + 5(1 − 1.4) = 35 °C (overshoots below set-point).
Results D — Fever
New set-point (°C)
After (°C)
No rows yet.
Worked example: 37 + 0.5(39 − 37) = 38.0 °C.
Discussion
Each run confirmed that negative feedback drives the variable toward its set-point, that more cycles close the gap, that high gain causes overshoot and oscillation, and that raising the set-point (fever) makes the body warm itself up.
Conclusion
Homeostasis is maintained by negative feedback loops whose gain must be tuned for a quick, stable return to the set-point; shifting the set-point itself, as in fever, moves the regulated value to a new target.
Practice Questions
1
A body at 34 °C has a correction gain of 0.5. What is its temperature after one correction?
Hint: 34 + 0.5(37 − 34) = 35.5 °C.
2
Why is high loop gain not always better for a control system?
Hint: It overshoots the set-point and can oscillate or become unstable.
3
Childbirth (oxytocin) and blood clotting are examples of positive feedback. How does positive feedback differ from negative feedback?
Hint: Positive feedback amplifies the change (drives the variable further from the start) rather than opposing it.
Virginia Research Institute