Master the quantitative side of microscopy through four experiments: total magnification, field of view, resolution, and calculating actual specimen size. In each, predict the result yourself, then run the bench and check. Units: ×, µm, nm.
Theory: Microscopy
Seeing the small
A compound light microscope magnifies with two lenses and resolves fine detail up to a limit set by the wavelength of light. Its key quantities are magnification, field of view, resolution, and the actual size of what you measure.
Key relationships
Total magnification = ocular × objective | FOV ≈ 180000 / magnification (µm) | Resolution d = 0.61·λ/NA | Actual size = image size ÷ magnification
Higher magnification means a smaller field of view.
Magnification and field of view
Total magnification is the eyepiece times the objective. As it rises, the field of view shrinks, so you see less area in more detail.
Resolution
Resolution — the smallest separation still seen as two points — is set by d = 0.61·λ/NA. Because light's wavelength is ~550 nm, a light microscope cannot resolve much below ~200 nm.
Actual size
To find a specimen's true size, divide the measured image size by the magnification.
Apparatus
The elements of a microscopy study. In the simulation these are modeled for you.
Microscope
Eyepiece, objectives, and stage.
Field of View
Shrinks as magnification rises.
Resolution
Improves (d falls) with numerical aperture.
Actual Size
Image size divided by magnification.
Instructions
The Simulation has four experiments on tabs. In each, set the control, work out the answer yourself first, enter your prediction, and press Check. Record every run. The 3D benches can be rotated and zoomed; the graph tabs show curves.
Experiment A: Total Magnification
1
On the Magnification tab, choose an objective. Predict the total magnification = ocular × objective, then check.
Experiment B: Field of View
2
On the Field of View tab, choose an objective. Predict the FOV = 180000 / magnification, then check.
Experiment C: Resolution
3
On the Resolution tab, set the numerical aperture. Predict the resolution d = 0.61·λ/NA, then check.
Experiment D: Actual Specimen Size
4
On the Actual Size tab, set the image size and magnification. Predict the actual size = image ÷ magnification, then check.
Simulation
Microscopy Virtual LabFour experiments — pick a tab, predict, then check.
Text view
A chosen objective. Work out the total magnification, then check.
A compound microscope with a rotating objective turret above the stage.
Total Magnification
Readout
Objective40×
Ocular10×
Total— hidden
Predict the total magnification, then check.
Text view
A chosen objective. Work out the field of view, then check.
Field of view versus total magnification. The amber line marks your chosen magnification.
Field of View
Readout
Objective10× (total 100×)
Field of view— hidden
Predict the field of view, then check.
Text view
A set numerical aperture. Work out the resolution limit, then check.
Resolution limit versus numerical aperture; a higher NA gives a smaller (better) d. The amber line marks your NA.
Resolution
Readout
NANA 1.00
Resolution d— hidden
Predict the resolution limit d (nm), then check.
Text view
A set image size and magnification. Work out the actual size, then check.
The specimen on the stage; its measured image size and the magnification give the true size.
Actual Specimen Size
Readout
Image size40 mm
Magnification400×
Actual size— hidden
Predict the actual specimen size (µm), then check.
Team Questions
Question 1. (A) What is the total magnification with a 10× ocular and a 40× objective?
Question 2. (A) Besides the eyepiece, which lens determines total magnification?
Question 3. (B) As magnification increases, what happens to the field of view?
Question 4. (B) What is the field of view at 100× total (FOV = 180000 / mag)?
Question 5. (C) What fundamentally limits the resolution of a light microscope?
Question 6. (C) What is the resolution at NA = 1.0 (d = 0.61 × 550 / NA)?
Question 7. (D) A cell's image is 40 mm across at 400×. What is its actual size in µm?
Question 8. (D) What is the formula for actual specimen size?
Microscopy — Four Experiments
Biology | Section: [Your Section] | Date: [Date]
Lab Members: [Names of all members present]
Purpose
To master the quantitative side of microscopy through four experiments: total magnification, field of view, resolution, and calculating actual specimen size.
Theory
Total magnification = ocular × objective; FOV ≈ 180000/mag (µm); resolution d = 0.61·λ/NA; and actual size = image size ÷ magnification.
Results A — Magnification
Objective
Total
No rows yet.
Worked example: 10 × 40 = 400×.
Results B — Field of View
Total mag
FOV (µm)
No rows yet.
Worked example: 180000 / 100 = 1800 µm.
Results C — Resolution
NA
d (nm)
No rows yet.
Worked example: 0.61 × 550 / 1.0 ≈ 336 nm.
Results D — Actual Size
Image (mm)
Mag
Actual (µm)
No rows yet.
Worked example: 40 mm / 400 = 0.1 mm = 100 µm.
Discussion
Total magnification was the product of the two lenses; field of view fell as magnification rose; resolution improved with numerical aperture; and dividing image size by magnification recovered the true specimen size.
Conclusion
Microscopy trades area for detail: more magnification means a smaller field, resolution is capped by the wavelength of light, and quantitative measurements require dividing the image size by the magnification.
Practice Questions
1
Switching from the 10× to the 40× objective (10× ocular), how do total magnification and field of view change?