Virginia Research Institute
Virginia Research Institute
Virtual Laboratory  ·  Built by E2 Innovations
← Back to Virtual Labs|Microscopy
General Biology · Lab Skills

Microscopy

Master the quantitative side of microscopy through four experiments: total magnification, field of view, resolution, and calculating actual specimen size. In each, predict the result yourself, then run the bench and check. Units: ×, µm, nm.

Theory: Microscopy

Seeing the small

A compound light microscope magnifies with two lenses and resolves fine detail up to a limit set by the wavelength of light. Its key quantities are magnification, field of view, resolution, and the actual size of what you measure.

Key relationships Total magnification = ocular × objective  |  FOV ≈ 180000 / magnification (µm)  |  Resolution d = 0.61·λ/NA  |  Actual size = image size ÷ magnification
Higher magnification means a smaller field of view.

Magnification and field of view

Total magnification is the eyepiece times the objective. As it rises, the field of view shrinks, so you see less area in more detail.

Resolution

Resolution — the smallest separation still seen as two points — is set by d = 0.61·λ/NA. Because light's wavelength is ~550 nm, a light microscope cannot resolve much below ~200 nm.

Actual size

To find a specimen's true size, divide the measured image size by the magnification.

Apparatus

The elements of a microscopy study. In the simulation these are modeled for you.

Microscope
Eyepiece, objectives, and stage.
Field of View
Shrinks as magnification rises.
Resolution
Improves (d falls) with numerical aperture.
Actual Size
Image size divided by magnification.

Instructions

The Simulation has four experiments on tabs. In each, set the control, work out the answer yourself first, enter your prediction, and press Check. Record every run. The 3D benches can be rotated and zoomed; the graph tabs show curves.

Experiment A: Total Magnification
1
On the Magnification tab, choose an objective. Predict the total magnification = ocular × objective, then check.
Experiment B: Field of View
2
On the Field of View tab, choose an objective. Predict the FOV = 180000 / magnification, then check.
Experiment C: Resolution
3
On the Resolution tab, set the numerical aperture. Predict the resolution d = 0.61·λ/NA, then check.
Experiment D: Actual Specimen Size
4
On the Actual Size tab, set the image size and magnification. Predict the actual size = image ÷ magnification, then check.

Simulation

Microscopy Virtual LabFour experiments — pick a tab, predict, then check.
A compound microscope with a rotating objective turret above the stage.

Total Magnification

Readout
Objective40×
Ocular10×
Total— hidden
Predict the total magnification, then check.

Team Questions

Question 1. (A) What is the total magnification with a 10× ocular and a 40× objective?
Question 2. (A) Besides the eyepiece, which lens determines total magnification?
Question 3. (B) As magnification increases, what happens to the field of view?
Question 4. (B) What is the field of view at 100× total (FOV = 180000 / mag)?
Question 5. (C) What fundamentally limits the resolution of a light microscope?
Question 6. (C) What is the resolution at NA = 1.0 (d = 0.61 × 550 / NA)?
Question 7. (D) A cell's image is 40 mm across at 400×. What is its actual size in µm?
Question 8. (D) What is the formula for actual specimen size?

Microscopy — Four Experiments

Biology | Section: [Your Section] | Date: [Date]

Lab Members: [Names of all members present]

Purpose

To master the quantitative side of microscopy through four experiments: total magnification, field of view, resolution, and calculating actual specimen size.

Theory

Total magnification = ocular × objective; FOV ≈ 180000/mag (µm); resolution d = 0.61·λ/NA; and actual size = image size ÷ magnification.

Results A — Magnification

ObjectiveTotal
No rows yet.

Worked example: 10 × 40 = 400×.

Results B — Field of View

Total magFOV (µm)
No rows yet.

Worked example: 180000 / 100 = 1800 µm.

Results C — Resolution

NAd (nm)
No rows yet.

Worked example: 0.61 × 550 / 1.0 ≈ 336 nm.

Results D — Actual Size

Image (mm)MagActual (µm)
No rows yet.

Worked example: 40 mm / 400 = 0.1 mm = 100 µm.

Discussion

Total magnification was the product of the two lenses; field of view fell as magnification rose; resolution improved with numerical aperture; and dividing image size by magnification recovered the true specimen size.

Conclusion

Microscopy trades area for detail: more magnification means a smaller field, resolution is capped by the wavelength of light, and quantitative measurements require dividing the image size by the magnification.

Practice Questions

1
Switching from the 10× to the 40× objective (10× ocular), how do total magnification and field of view change?
Hint: Magnification rises 100× → 400× (4×); FOV falls 1800 → 450 µm (to a quarter).
2
Why can an electron microscope resolve far finer detail than a light microscope?
Hint: Electrons have a much shorter wavelength than visible light, so d = 0.61·λ/NA is far smaller.
3
A specimen's image is 24 mm long at 100×. Find its actual length in µm.
Hint: 24 / 100 = 0.24 mm = 240 µm.
© 2026 E2 Innovations LLC / Virginia Research Institute. All rights reserved. Licensed for use on E2 Innovations and VRI sites only — not for redistribution or reuse in other courses. Contact info@e2innovations.ai.