Investigate breathing through five experiments: minute and alveolar ventilation, lung volumes and capacities, the effect of breathing pattern on dead-space ventilation, lung compliance, and alveolar gas exchange. In each, predict the result yourself, then run the bench and check. Volumes are in mL or L, pressures in cmH2O or mmHg.
Theory: Pulmonary Ventilation
Moving air
Ventilation is the movement of air into and out of the lungs. The tidal volume (TV) is the air per breath; the respiratory rate (RR) is breaths per minute.
Key relationships
Minute ventilation = TV × RR | Alveolar ventilation = (TV − dead space) × RR | VC = TV + IRV + ERV
Anatomical dead space ≈ 150 mL — air in the conducting airways that never reaches the alveoli.
Dead space and alveolar ventilation
Not all inhaled air reaches the alveoli: about 150 mL fills the dead space (the conducting airways). Only the alveolar ventilation takes part in gas exchange, which is why rapid, shallow breathing is less effective than slow, deep breathing at the same minute ventilation.
Lung volumes and capacities
Beyond tidal breathing, the inspiratory and expiratory reserve volumes (IRV, ERV) can be added, and a residual volume (RV) always remains. The vital capacity (VC = TV + IRV + ERV) is the most air that can be moved; adding RV gives the total lung capacity.
Compliance
Compliance is how easily the lungs stretch: C = ΔV/ΔP. Stiff (low-compliance) lungs, as in fibrosis, need more pressure for the same volume change.
Alveolar gas
The alveolar gas equation gives the alveolar oxygen pressure: PAO₂ = PIO₂ − PACO₂/R, with inspired PIO₂ ≈ 150 mmHg and respiratory quotient R ≈ 0.8. Oxygen then diffuses from the alveolus into the blood, which arrives at about 40 mmHg.
Apparatus
The quantities a ventilation study tracks. In the simulation these are modeled for you.
Lungs
Tidal volume moves in and out each breath.
Lung Volumes
IRV, TV, ERV, and RV stack to total capacity.
Compliance
Volume change per unit pressure.
Gas Exchange
O₂ diffuses from alveolus to blood.
Instructions
The Simulation has five experiments on tabs. In each, set the control, work out the answer yourself first, enter your prediction, and press Check. Record every run. The lung benches can be rotated and zoomed; the others show a graph.
Experiment A: Minute & Alveolar Ventilation
1
On the Ventilation tab, set tidal volume and respiratory rate. Predict the alveolar ventilation = (TV − 150) × RR ÷ 1000 (L/min), then check.
Experiment B: Lung Volumes & Capacities
2
On the Volumes tab, set the inspiratory and expiratory reserve volumes. Predict the vital capacity VC = TV + IRV + ERV, then check against the spirogram.
Experiment C: Breathing Pattern
3
On the Pattern tab, change the respiratory rate at a fixed 6 L/min minute ventilation. Predict the alveolar ventilation and see why rapid, shallow breathing is less effective.
Experiment D: Compliance
4
On the Compliance tab, set the pressure change. Predict the volume change ΔV = C × ΔP, then check.
Experiment E: Alveolar Gas Exchange
5
On the Gas Exchange tab, set the alveolar CO₂. Predict the alveolar oxygen pressure PAO₂ = 150 − PACO₂/0.8, then check.
Simulation
Pulmonary Ventilation Virtual LabFive experiments — pick a tab, predict, then check.
Text view
Lungs at a set tidal volume and rate. Work out the alveolar ventilation, then check.
The lungs inflate at the set rate and depth. Alveolar ventilation is the air per minute that reaches the alveoli.
Alveolar Ventilation
Readout
Tidal volume500 mL
Rate12 /min
Minute ventilation6.0 L/min
Alveolar ventilation— hidden
Predict the alveolar ventilation (L/min), then check.
Text view
Lung volumes at set reserves. Work out the vital capacity, then check.
The lung volumes stacked to total lung capacity. Vital capacity is everything except the residual volume.
Lung Volumes
Readout
Tidal volume500 mL
Insp. reserve3000 mL
Exp. reserve1100 mL
Residual1200 mL
Vital capacity— hidden
Predict the vital capacity, then check.
Text view
A breathing pattern at fixed minute ventilation. Work out the alveolar ventilation, then check.
Alveolar ventilation versus respiratory rate, at a fixed 6 L/min minute ventilation. Faster, shallower breathing loses more to dead space.
Breathing Pattern
Readout
Rate12 /min
Tidal volume500 mL
Minute ventilation6.0 L/min
Alveolar ventilation— hidden
Predict the alveolar ventilation at this breathing pattern, then check.
Text view
Lungs at a set pressure change. Work out the volume change from compliance, then check.
The volume–pressure line. A steeper line means a more compliant (easier-to-stretch) lung.
Compliance
Readout
Pressure change10 cmH₂O
Compliance0.2 L/cmH₂O
Volume change— hidden
Predict the volume change at this pressure, then check.
Text view
An alveolus at a set CO2. Work out the alveolar oxygen pressure, then check.
Alveoli (pink) sit against a capillary (red). Oxygen (blue) diffuses from the alveolar gas into the blood.
Alveolar Gas Exchange
Readout
Alveolar CO₂40 mmHg
Alveolar PO₂— hidden
Predict the alveolar oxygen pressure, then check.
Team Questions
Question 1. (A) With TV = 500 mL and RR = 12/min, what is the alveolar ventilation (L/min)?
Question 2. (A) Why is alveolar ventilation less than minute ventilation?
Question 3. (B) With TV 500, IRV 3000, ERV 1100 mL, what is the vital capacity (mL)?
Question 4. (B) Which lung volume cannot be exhaled and always remains in the lungs?
Question 5. (C) At a fixed minute ventilation, does rapid shallow breathing raise or lower alveolar ventilation?
Question 6. (D) With ΔP = 10 cmH₂O and C = 0.2 L/cmH₂O, what is the volume change (L)?
Question 7. (D) Does a stiff, low-compliance lung expand more or less for the same pressure?
Question 8. (E) With alveolar CO₂ = 40 mmHg, what is the alveolar PO₂ (mmHg)?
Pulmonary Ventilation — Five Experiments
Biology | Section: [Your Section] | Date: [Date]
Lab Members: [Names of all members present]
Purpose
To investigate pulmonary ventilation: minute and alveolar ventilation, lung volumes and capacities, the effect of breathing pattern on dead-space ventilation, lung compliance, and alveolar gas exchange.
Theory
Minute ventilation = TV × RR; alveolar ventilation = (TV − dead space) × RR; VC = TV + IRV + ERV. Compliance C = ΔV/ΔP. The alveolar gas equation gives PAO₂ = 150 − PACO₂/0.8.
Alveolar ventilation was always below minute ventilation because of dead space, and fell sharply with rapid shallow breathing. Vital capacity summed the usable volumes; compliance set the volume per pressure; and the alveolar gas equation predicted the oxygen available for diffusion.
Conclusion
Effective ventilation depends not just on how much air is moved but on how much reaches the alveoli, on the mechanical compliance of the lungs, and on the alveolar gas composition that drives diffusion.
Practice Questions
1
A patient breathes 600 mL at 15/min. Find the minute and alveolar ventilation.