Virginia Research Institute
Virginia Research Institute
Virtual Laboratory  ·  Built by E2 Innovations
← Back to Virtual Labs|Radioactive Decay Law, Half-Life, and Decay Chains
Nuclear Physics · Radioactive Decay

Radioactive Decay Law, Half-Life, and Decay Chains

Work as a radiochemistry technician measuring half-lives and tracking decay chains. Milk a short-lived barium-137m sample from a caesium-137 isotope generator, count it with a Geiger–Müller counter in 30-second intervals, and work out the net count rate, the half-life, and the activity from your own data. Then seal radium, strontium, and caesium sources and follow the ingrowth of their daughters to secular equilibrium, the physics behind radon testing, Y-90 therapy sources, and gamma check sources. Two graph work areas then take the analysis further: fitting a half-life to a full set of decay data, with its uncertainty, and comparing secular, transient, and no-equilibrium ingrowth curves the way a radiochemist plans when to milk a generator. In every part you work out the answer yourself, then check it.

Theory: The Decay Law and Decay Chains

Why Half-Life Measurements Matter

The half-life of a radionuclide identifies it, sets how long a source stays useful, decides how long waste must be stored, and fixes the dose a patient receives from a medical isotope. Radiochemistry laboratories confirm half-lives by counting, nuclear medicine departments decay-correct every dose, and radon testers rely on the predictable growth of radon from radium. Most radionuclides also decay into radioactive daughters, so a sealed source often contains a whole decay chain whose activities are linked.

The Exponential Decay Law

Every nucleus of a radionuclide has the same probability per second of decaying, the decay constant λ. The number of nuclei, the activity, and the count rate all fall exponentially. A graph of ln R against time is a straight line with slope −λ, which is how half-lives are measured.

Decay Law N(t) = N₀ e^(−λt)     A = λN     A(t) = A₀ e^(−λt) = A₀ (1/2)^(t/T½)
T½ = ln 2 / λ     From two count rates: λ = ln(R₁/R₂) / (t₂ − t₁)
ln R falls in a straight line with slope −λ

Counting a Sample

A Geiger–Müller counter records only a fraction of the decays, its efficiency ε, and also counts natural background. The net count rate is the gross rate minus background, and the activity is the net rate divided by the efficiency. Because decays are random, a count of C has an uncertainty of about √C, so large counts give precise rates. The Ba-137m in this lab comes from a Cs-137 isotope generator: barium is washed (eluted) off a column that holds the long-lived caesium parent, giving a fresh sample with a 2.552-minute half-life that can be measured in one class period.

Counting Net rate R = C/t_count − B     Activity A = R/ε   (Bq = decays per second)
Use intervals far apart in time for the most precise half-life

Decay Chains and Secular Equilibrium

When a parent P decays into a radioactive daughter D, the daughter builds up after the source is made or sealed. If the parent lives much longer than the daughter (T½,P ≫ T½,D), the parent activity is effectively constant and the daughter activity grows until it equals the parent activity times the branching ratio (the fraction of parent decays that produce that daughter). This is secular equilibrium. It takes about 7 daughter half-lives to reach more than 99%.

Daughter Ingrowth (T½,P ≫ T½,D) A_D(t) = BR × A_P × (1 − e^(−λ_D t))
Equilibrium: A_D = BR × A_P     Time to 99%: t = ln(100)/λ_D ≈ 6.64 T½,D
After one daughter half-life, A_D = ½ BR A_P

Data Used in This Lab

NuclideHalf-lifeNotes
Ba-137m2.552 minIsomer; emits a 661.7 keV gamma ray
Cs-13730.08 y94.4% of decays go to Ba-137m
Ra-226 → Rn-2221600 y → 3.8235 dRadon gas ingrowth in soil, buildings, and sealed sources
Sr-90 → Y-9028.79 y → 64.0 hY-90 is a pure β⁻ emitter used in cancer therapy and in RTG sources

Data from the DOE Fundamentals Handbook (Nuclear Physics and Reactor Theory, Module 1) and NNDC NuDat. The counter in this lab has an efficiency of 5.0% and a background of 0.5 counts per second; dead time is negligible at these count rates.

Nuclear medicine

Every dose is decay-corrected from its calibration time; generators supply short-lived daughters on demand.

Radon testing

Radon-in-air measurements and sealed Ra-226 standards rely on secular equilibrium.

Waste management

Decay-in-storage of short-lived waste for 10 half-lives cuts its activity by a factor of 1000.

Fitting Decay Data and Reading Ingrowth Curves

Because ln R = ln R₀ − λt, measured count rates fall on a straight line on a semi-log plot. A least-squares fit of ln R against t uses every point, so it is less sensitive to the scatter in any one count, and the scatter of the residuals gives the standard uncertainty of the slope and so of the half-life. For a parent–daughter pair starting from pure parent, A_D(t) = BR·A_P0·λ_D/(λ_D − λ_P)·(e^(−λ_P t) − e^(−λ_D t)). If the parent lives much longer than the daughter the activities become equal (secular equilibrium); if it lives somewhat longer they settle into a fixed ratio (transient equilibrium); if the parent is shorter-lived, no equilibrium forms. The daughter activity is largest at t_max = ln(λ_D/λ_P)/(λ_D − λ_P).

Apparatus

The equipment used for half-life and decay-chain measurements. In the simulation these are modelled for you, and the readings correspond to what each instrument would show.

Cs-137/Ba-137m generator
A column of Cs-137; an eluting solution washes off the Ba-137m daughter on demand.
GM tube and planchet
The sample sits on a planchet in a fixed geometry under the end-window GM tube.
81223
Scaler and timer
Counts the pulses in each preset 30-second interval and steps on automatically.
Sealed source capsule
A welded capsule keeps radon and other daughters inside, so they grow into equilibrium.
Semi-log graph
Plotting ln R (or R on a log scale) against time turns exponential decay into a straight line.
Timer
Times elution so every interval is referenced to t = 0.

Instructions: Running the Virtual Experiment

You are measuring a half-life and checking source ingrowth in a radiochemistry laboratory. The simulation has two immersive 3D work areas and two graph work areas. The parts build from undergraduate work in Parts A and B to graduate-level analysis in the last step of Parts C and D; the level of each part is shown beside its title. In each one you set up the measurement, take readings, work out the answer yourself, enter it, and press Check. Record every reading and calculation in your lab report tables (modelled in the Example Report), with a labelled screenshot of each setup. Drag in any 3D view to orbit, and scroll to zoom.

Part A: Half-Life of Ba-137m (3D Half-Life Bench)Undergraduate
1
Open Simulation → 3D Half-Life Bench and press Elute and start counting. Wait until all ten intervals are counted. Copy the ten counts into Table A.
2
Set k = 1. Choose Predict: net count rate R_k, calculate it, and check it. Repeat for every interval, pressing Record this run each time, and calculate ln R_k.
3
Set k = 10. Choose Predict: half-life from intervals 1 and k, calculate T½, and check it. Repeat for k = 3 and k = 6, and compare the three values with 2.552 min.
4
Choose Predict: Ba-137m activity for k = 1 and check it. Then set the prediction time to 6.00 min, choose Predict: net count rate at time t, and check it. Plot ln R against t, draw the best-fit line, and find λ from its slope.
Part B: Daughter Ingrowth and Secular Equilibrium (3D Daughter Ingrowth)Undergraduate
1
Open 3D Daughter Ingrowth. Choose Ra-226 → Rn-222 and set A_P = 20 kBq. Choose Predict: daughter decay constant and check it.
2
Set t = 7.0 days. Choose Predict: daughter activity A_D(t), calculate it, and check it. Press Record this run. Repeat for t = 3.8, 14.0, and 25.4 days.
3
Check the equilibrium activity and the time to reach 99%. Repeat Part B for Sr-90 → Y-90 and Cs-137 → Ba-137m. Record all runs in Table B and explain why Ba-137m never reaches the full Cs-137 activity.
Part C: Fitting a Half-Life to Decay Data (Graph: Decay Data)Upper undergraduateGraduate step
1
Open Graph: Decay Data. Choose Ba-137m and the chord points 1 and 8. Check the decay constant λ and the two-point half-life. Press Record this run.
2
Change the chord to points 1 and 4 and check the half-life again. Note how much it changes. Then check the least-squares half-life from all eight points and record it in Table C.
3
Repeat steps 1 and 2 for In-116m and Mn-56 (points 1 and 8). Take a labelled screenshot of one graph showing the points, the chord, and the fitted line.
4
GraduateFor each nuclide, check the standard uncertainty of the least-squares half-life. Record it in Table C and state how many standard uncertainties your fitted value lies from the accepted half-life. Is the difference significant?
Part D: Secular, Transient, and No Equilibrium (Graph: Ingrowth)Upper undergraduateGraduate step
1
Open Graph: Ingrowth. Choose Mo-99 → Tc-99m and set t = 24 h. Check the daughter activity and the equilibrium activity ratio. Press Record this run.
2
Check and record Mo-99 at 12 h and 48 h; Sr-90 → Y-90 at 100 h and 300 h; and Te-131 → I-131 at 1 h and 6 h. Record all runs in Table D. For Te-131, explain the message you get when you ask for the equilibrium ratio.
3
From the graphs, describe the three shapes: secular, transient, and no equilibrium. Explain why a Tc-99m generator is eluted about once a day.
4
GraduateDerive the time of maximum daughter activity by setting dA_D/dt = 0, then check t_max for all three pairs. Record it in Table D and show from the graph that A_D equals BR × A_P at that moment.

Simulation: Half-Life Counting Bench, Decay-Chain Ingrowth, and Analysis Graphs

Radioactive Decay Virtual LabSet up the equipment, work out your answer, then Check

Elute the generator to get a fresh Ba-137m sample, then count it in ten consecutive 30-second intervals. Interval k runs from (k − 1) × 0.5 min to k × 0.5 min, so its midpoint is t_k = (k − 0.5) × 0.5 min. Part A uses this bench.

Drag to orbit · scroll to zoom. 3D counting bench: the Cs-137 isotope generator column, the eluted Ba-137m sample on a planchet under the Geiger–Müller tube, and the scaler. The board plots your count rate on a logarithmic scale against time, which gives a straight line for exponential decay.

Setup

Readings

Interval counts (30 s each)—
Counts in interval k—
Background rate B—
Counter efficiency ε—
Status—

Each eluted sample has a slightly different starting activity, so your numbers will differ from your classmates'.

Work it out, then check

Table A: your half-life counting record
kt_k (min)CountsNet rate R_k (cps)ln R_kT½ from 1 and k (min)Activity (Bq)

A long-lived parent is sealed in a source capsule at t = 0 with no daughter present. The daughter grows in until its activity equals the parent activity times the branching ratio: secular equilibrium. Part B uses this work area.

Drag to orbit · scroll to zoom. 3D sealed source: parent atoms (gold) stay nearly constant while daughter atoms (purple) build up after the source is sealed. The two activity bars show the parent and daughter activities approaching equilibrium.

Setup

Readings

Parent half-life—
Daughter half-life T½,D—
Branching ratio to this daughter—
Time since sealing—

The parent half-life is so long that A_P is constant over the times used here.

Work it out, then check

Table B: your ingrowth record
PairA_P (kBq)tt / T½,DA_D (kBq)A_D / A_P

A counting laboratory measures a short-lived source at regular intervals (20 s counts, background already subtracted). A two-point half-life is quick; a least-squares fit to every point is better and also gives an uncertainty. Part C uses this work area.

Semi-log plot of measured net count rate against time for the chosen nuclide. Dots are the measurements, the dashed line is the two-point chord you chose, and the solid line is the least-squares fit of ln R against t.

Show the plotted values

Setup

Readings

Measured data (t, R)—
Chord points—
Count time per point—
Accepted half-life—

Two points: λ = ln(R_i/R_j)/(t_j − t_i). Least squares: fit ln R = a + bt; T½ = ln 2/(−b). These data contain real counting scatter.

Work it out, then check

Table C: your decay-data record
NuclidePointsλ two-point (min⁻¹)T½ two-point (min)T½ least squares (min)σ(T½) (min)

Start with a pure parent source of 100 MBq. How the daughter grows in depends on the ratio of the two half-lives. Part D uses this work area.

Parent and daughter activities against time after a pure parent source is prepared (logarithmic activity axis). The vertical marker is the time you selected.

Show the plotted values

Setup

Readings

Parent half-life—
Daughter half-life—
Branching to this daughter—
Parent activity at t—

A_D(t) = BR·A_P0·λ_D/(λ_D − λ_P)·(e^(−λ_P t) − e^(−λ_D t)). Half-lives and branching are rounded nuclear data.

Work it out, then check

Table D: your ingrowth record
Pairt (h)A_P (MBq)A_D (MBq)A_D/A_Pt_max (h)

These immersive 3D work areas and interactive graph work areas are the main version; the accessible copy delivers the same set-up, work-out, and check exercises with native controls and screen-reader announcements.

Team Questions

Question 1. Ba-137m has a half-life of 2.552 min. What is its decay constant, in units of 10⁻³ s⁻¹? (e.g. 4.53)
Question 2. What fraction of a radioactive sample remains after 4 half-lives? (decimal)
Question 3. A Ba-137m sample gives a net 2000 cps. What will the net count rate be 5.0 min later, in cps?
Question 4. An unknown sample gives a net 1200 cps at t = 1.0 min and 300 cps at t = 6.0 min. What is its half-life, in minutes?
Question 5. A counter with 5.0% efficiency records a net 500 cps. What is the activity of the sample, in Bq?
Question 6. A 20 kBq Ra-226 source is sealed with no radon inside. What is the Rn-222 activity (T½ = 3.8235 d) after 7.0 days, in kBq?
Question 7: Challenge. How long after a Sr-90 source is purified does Y-90 (T½ = 64.0 h) reach 99% of equilibrium, in hours?

Example Lab Report

Sample report showing the expected format and level of detail. Use it as a guide for your own submission, and include labelled screenshots of each setup. Your counts will differ from these because every eluted sample and every count is different.

Radioactive Decay Law, Half-Life, and Decay Chains

Nuclear Physics | Section: [Your Section] | Date: [Date]

Lab Members: [Names of all members present]

Purpose

To measure the half-life of Ba-137m by counting successive intervals with a Geiger–Müller counter; to calculate net count rates, activities, and predicted count rates; and to follow the ingrowth of radioactive daughters to secular equilibrium, and to analyse full decay data sets and parent–daughter ingrowth on graphs, including a least-squares half-life with its uncertainty and the time of maximum daughter activity.

Theory

Activity decays as A = A₀e^(−λt), so ln R is linear in time with slope −λ, and T½ = ln 2/λ. Net rate is R = C/t − B and activity is A = R/ε. For a long-lived parent, the daughter grows as A_D = BR × A_P(1 − e^(−λ_D t)).

R = C/30 − B  ·  λ = ln(R₁/R_k)/(t_k − t₁)  ·  A = R/ε  ·  A_D = BR A_P(1 − e^(−λ_D t))

Table A: Ba-137m Counting (B = 0.5 cps, ε = 5.0%) Undergraduate

kt_k (min)CountsR_k (cps)ln R_kT½ from 1 and k (min)Activity (Bq)
10.25140 1804672.178.4494—93 443
20.75122 6434087.608.31572.59381 752
31.25106 8413560.878.17782.55271 217
41.7593 2443107.638.04162.55062 153
52.2581 2232706.937.90362.54054 139
62.7571 0862369.037.77022.55247 381
73.2562 3882079.107.63972.56841 582
83.7554 3241810.307.50122.55936 206
94.2547 5671585.077.36842.56531 701
104.7541 3821378.907.22902.55627 578

Sample calculation (k = 10): R = 41 382/30 − 0.5 = 1378.90 cps; λ = ln(4672.17/1378.90)/4.50 = 0.2713 min⁻¹; T½ = 0.6931/0.2713 = 2.556 min. Best-fit slope of ln R against t: −0.2712 min⁻¹, giving T½ = 2.556 min (0.2% from 2.552 min). Predicted rate at 6.00 min: 4672.17 × (1/2)^(5.75/2.552) = 980 cps.

Table B: Daughter Ingrowth (A_P = 20 kBq) Undergraduate

Pairtt / T½,DA_D (kBq)A_D / A_P
Ra-226 → Rn-2223.8 d0.9949.960.498
Ra-226 → Rn-2227.0 d1.83114.380.719
Ra-226 → Rn-22214.0 d3.66218.420.921
Ra-226 → Rn-22225.4 d6.64319.800.990
Sr-90 → Y-9010.0 d3.75018.510.926
Cs-137 → Ba-137m10.0 min3.91817.630.882

Time to 99% of equilibrium: Rn-222, 25.4 d; Y-90, 17.7 d (425 h); Ba-137m, 17.0 min. Equilibrium activities: 20.0, 20.0, and 18.88 kBq.

Table C: Decay-Data Fits Upper undergraduateGraduate step

NuclidePointsλ two-point (min⁻¹)T½ two-point (min)T½ least squares (min)σ(T½) (min)
Ba-137m1 and 80.262292.6432.5880.041
Ba-137m1 and 40.276282.5092.5880.041
In-116m1 and 80.0128653.89452.7851.352
Mn-561 and 80.00446155.469158.7772.437

Accepted half-lives: Ba-137m 2.552 min, In-116m 54.29 min, Mn-56 154.73 min.

Graduate step: the fitted values lie 0.9σ (Ba-137m), 1.1σ (In-116m), and 1.7σ (Mn-56) from the accepted half-lives, so none of the differences is significant at the 2σ level.

Table D: Ingrowth from 100 MBq of Pure Parent Upper undergraduateGraduate step

Pairt (h)A_P (MBq)A_D (MBq)A_D/A_Pt_max (h)
Sr-90 → Y-9010099.9766.130.6615764.69
Sr-90 → Y-9030099.9296.060.9614764.69
Mo-99 → Tc-99m1288.1560.830.6922.84
Mo-99 → Tc-99m2477.768.850.88622.84
Mo-99 → Tc-99m4860.3857.810.957522.84
Te-131 → I-131118.950.17490.0092343.70
Te-131 → I-13160.0046260.212245.873.70

Equilibrium ratios: Sr-90/Y-90 1.0003 (secular); Mo-99/Tc-99m 0.876 × 1.1001 = 0.9638 (transient); Te-131/I-131 none (the parent is shorter-lived than the daughter).

Graduate step: t_max = ln(λ_D/λ_P)/(λ_D − λ_P) = 764.7 h (Sr-90/Y-90), 22.84 h (Mo-99/Tc-99m), and 3.70 h (Te-131/I-131). At t_max the daughter curve crosses BR × A_P.

Discussion

The ln R values fell on a straight line, confirming exponential decay. Half-lives from interval 1 paired with nearby intervals scattered more (2.593 min for k = 2) than pairs far apart (2.556 min for k = 10), because the counting uncertainty is a larger fraction of a small change in rate. The best-fit line gave 2.556 min, within 0.2% of the accepted 2.552 min. The activity fell from about 93 kBq to 28 kBq during the five minutes of counting.

Each daughter reached half its equilibrium activity after one daughter half-life and 99% after about 6.6 half-lives, whatever the absolute time scale: 25 days for radon, 18 days for Y-90, 17 minutes for Ba-137m. This is why a sealed radium source must sit for about a month before it is used as a radon standard. Ba-137m levelled off at 94.4% of the Cs-137 activity, because 5.6% of Cs-137 decays go directly to the ground state of Ba-137 and never produce the isomer.

The decay-data graph showed why a fit beats two points. For Ba-137m, two-point half-lives ranged from 2.509 to 2.643 min depending on which points were chosen, while the least-squares fit to all eight points gave 2.588 ± 0.041 min. The ingrowth graphs showed the three cases side by side: Y-90 grew to equal its parent and stayed there; Tc-99m peaked near 23 h and then fell with the Mo-99 half-life, which is why generators are eluted daily; and I-131 from Te-131 peaked within 4 h and was left decaying alone once the parent had gone.

The graduate steps added the numbers a laboratory would quote. The standard uncertainty turned "close to the accepted value" into a statement of significance, and the t_max derivation gave the best elution time without trial and error.

Conclusion

The measured half-life of Ba-137m was 2.556 min, in close agreement with 2.552 min. Daughter ingrowth followed A_D = BR A_P(1 − e^(−λ_D t)) and reached secular equilibrium after about seven daughter half-lives.

Practice Questions

Show all work and include units.

Question 1
A Tc-99m dose (T½ = 6.007 h) is calibrated at 740 MBq at 8:00 a.m. What is its activity at 1:30 p.m.?
Hint: decay-correct with A = A₀(1/2)^(t/T½).
Question 2
A count of 400 has a standard deviation of 20. What count is needed to reduce the relative uncertainty to 1%?
Hint: relative uncertainty = 1/√C.
Question 3
How many atoms of Ba-137m are present when the activity is 54 000 Bq?
Hint: N = A/λ, with λ in s⁻¹.
Question 4
Short-lived hospital waste (I-131, T½ = 8.025 d) is held for decay. How long must it be stored to reduce its activity by a factor of 1000?
Hint: (1/2)^n = 1/1000.
Question 5
Explain why secular equilibrium needs T½,P ≫ T½,D, and what happens instead when the parent's half-life is only a few times longer than the daughter's.
Hint: think about the Mo-99/Tc-99m generator (66 h and 6 h).
Question 6: Challenge
Using your Table A data, fit a straight line to ln R against t by least squares, find λ and T½, and estimate the uncertainty in T½ from the scatter of your points.
Hint: a spreadsheet LINEST or SLOPE function gives the slope and its standard error.
© 2026 E2 Innovations LLC / Virginia Research Institute. All rights reserved. Licensed for use on E2 Innovations and VRI sites only — not for redistribution or reuse in other courses. Contact info@e2innovations.ai.