Virginia Research Institute
Virginia Research Institute
Virtual Laboratory  ·  Built by E2 Innovations
← Back to Virtual Labs|Radiochemical Separations: Solvent Extraction and Ion Exchange
Nuclear Chemistry · Radiochemical Separations

Radiochemical Separations: Solvent Extraction and Ion Exchange

Work as a radiochemist in a fuel-cycle or environmental laboratory. Separate uranium from americium and caesium by solvent extraction with tributyl phosphate: find distribution ratios from tracer counts, then work out the fraction extracted, the fraction left after several contacts, and the decontamination factor. Then purify strontium-90 from its daughter yttrium-90 on an extraction-chromatography column: work out the free column volume, the retention volumes, the bed volumes to elution, and a safe load volume. Two graph work areas then turn the same chemistry into design tools: a plot of the fraction left after repeated contacts, compared with a countercurrent battery, and a plot of distribution ratio against nitric acid concentration for choosing a process acid window. The parts build from undergraduate calculations to graduate-level design. In every part you work out the answer yourself, then check it.

Theory: Radiochemical Separations

Why Separations Matter

Almost every task in nuclear chemistry needs one element pulled away from many others. Reprocessing plants recover uranium and plutonium from spent fuel. Environmental and bioassay laboratories isolate strontium-90 or actinides before counting them, because other radionuclides would swamp the signal. Radiopharmacies purify medical isotopes. Waste treatment removes caesium-137 and strontium-90 so the bulk of the waste can be classified as low-level. The two workhorse methods are solvent extraction and ion exchange, including extraction chromatography.

Solvent Extraction

An aqueous nitric acid solution is shaken with an immiscible organic solvent. In the PUREX process the solvent is 30% tributyl phosphate (TBP) in dodecane. TBP forms neutral complexes such as UO₂(NO₃)₂·2TBP, so uranium(VI) and plutonium(IV) move into the organic phase. Trivalent americium and monovalent caesium extract very little. Extraction rises with nitrate concentration (the salting-out effect) and then levels off or falls at high acid as nitric acid competes for the TBP.

Extraction Equations Distribution ratio: D = [M]org / [M]aq  (total concentrations)
Phase ratio: r = Vorg / Vaq
One contact: fraction extracted E = Dr / (1 + Dr)
n contacts with fresh solvent: fraction left in aqueous = (1 + Dr)−n
Decontamination factor: DF = (fraction of product recovered) / (fraction of impurity carried)
D is measured by counting equal aliquots of each phase after a tracer test
Species (30% TBP)1 M HNO₃3 M HNO₃6 M HNO₃
U(VI)about 8about 25about 20
Am(III)about 0.01about 0.02about 0.03
Cs(I)about 0.001 (essentially not extracted)

These D values are representative training values. In the lab you measure them yourself from the tracer counts.

Ion Exchange and Extraction Chromatography

In a column, a species is held on a solid resin and moves only while it is in the liquid. The distribution coefficient Kd (mL/g) is the ratio of the amount per gram of resin to the amount per mL of solution. The larger Kd is, the more solution must pass before the species comes out. Strontium-selective resin (a crown ether on an inert support) holds Sr²⁺ strongly in 8 M HNO₃ but hardly holds Y³⁺, so Y-90 rinses through and Sr-90 stays. Dilute acid then strips the Sr.

Column Equations Bed volume Vbed = m / ρ  ·  Free column volume V₀ = ε × Vbed
Retention volume: VR = V₀ + Kd × m
Retention in bed volumes = VR / Vbed
Load less than about half of VR(Sr) so the Sr-90 band never reaches the outlet

In this lab the bed density is ρ = 0.35 g/mL and the free-volume fraction is ε = 0.65. The 50% load rule is a simplified training rule; real methods find the breakthrough volume experimentally.

Countercurrent Extraction and the Acid Window

Repeated batch contacts each use fresh solvent, so the solvent volume grows with every contact. A countercurrent battery sends the solvent and the aqueous feed in opposite directions through N stages and uses one solvent volume. For an extraction factor E = Dr, the fraction left in the aqueous is given by the Kremser equation, φ = (E − 1)/(Eᴺ⁺¹ − 1). If E ≤ 1, no number of stages gives good recovery. The distribution ratio of each actinide also depends on the nitric acid concentration: nitrate helps form the neutral complex that TBP extracts, but at high acid the acid itself competes for TBP. A process acid must therefore be chosen inside a window that gives both high recovery of the product and a high decontamination factor from impurities.

Apparatus

The equipment used for the extraction and column separations. In the simulation these are modelled for you.

Separatory funnel
Contacts the aqueous feed with the organic solvent; the lighter organic phase floats on top.
30% TBP
TBP solvent
30 vol% tributyl phosphate in n-dodecane, pre-equilibrated with nitric acid.
Extraction-chromatography column
Packed with strontium-selective resin; flow is by gravity or vacuum box.
Fraction collector
Collects the eluate in equal fractions for counting.
4807 cps
Liquid scintillation counter
Counts 1 mL aliquots of each phase or fraction for alpha and beta emitters.
Radiological fume hood
All open radioactive work is done in a hood with contamination controls.

Instructions: Running the Virtual Experiment

You are the radiochemist running a separation. The simulation has two immersive 3D work areas and two graph work areas. The parts build from undergraduate work in Parts A and B to graduate-level design in the last step of Parts C and D; the level of each part is shown beside its title. In each one you set the conditions, work out the answer yourself, enter it, and press Check. Record every reading and calculation in your lab report tables (modelled in the Example Report), with a labelled screenshot of each setup. Drag in any 3D view to orbit, and scroll to zoom.

Part A: Solvent Extraction (3D Extraction Bench)Undergraduate
1
Open Simulation → 3D Extraction Bench. Choose U(VI), 3 M HNO₃, 100 mL organic, and 1 contact. From the tracer test, check D. Then check the % extracted, the % left, and the DF of U from Am. Press Record this run.
2
Set 3 contacts. Check the % left and the DF again, and record. Then return to 1 contact and repeat at 1 M and 6 M HNO₃, and with 50 mL organic at 3 M. Record each in Table A.
3
At 3 M, 100 mL, 1 contact, choose Am(III) and then Cs(I). Check D and the % extracted for each and record them. Note which species go with the uranium product and which stay in the raffinate.
Part B: Sr-90 / Y-90 Column Separation (3D Ion-Exchange Column)Undergraduate
1
Open 3D Ion-Exchange Column. Choose 8 M HNO₃ and 2.0 g resin. Check the free column volume V₀, then the retention volumes of Sr and Y.
2
Check the Sr retention in bed volumes and the safe load volume. Press Run elution and compare the peaks on the board with your values. Press Record this run.
3
Repeat with 4.0 g resin, and then with 3 M HNO₃ at 2.0 g and 4.0 g. Record all runs in Table B and decide which acid gives the better separation.
Part C: Repeated Contacts and Countercurrent Stages (Graph: Multiple Contacts)Upper undergraduateGraduate step
1
Open Graph: Multiple Contacts. Choose D = 2, r = 1, 3 contacts, and a target of 1%. Check the % left after n contacts, then the smallest number of batch contacts that meets the target. Press Record this run.
2
Repeat with r = 2 (1% target); D = 5 at r = 1 and D = 10 at r = 0.5 with a 0.1% target; and D = 1 at r = 1 (1% target). Record every run in Table C. From the graph, state why D = 10 at r = 0.5 behaves exactly like D = 5 at r = 1.
3
Take a labelled screenshot of the graph for one run. Count how many solvent volumes the batch method uses for each case.
4
GraduateFor the same cases, check the countercurrent stages N from the Kremser equation, which uses only one solvent volume. Record N in Table C. Then try D = 0.5 at r = 1 with a 10% target and explain why the tool reports that the target cannot be reached.
Part D: Choosing the Process Acid (Graph: Acid Dependence)Upper undergraduateGraduate step
1
Open Graph: Acid Dependence. Choose U(VI) at 3.0 M. Check D and the separation factor β = D_U/D_Am. Press Record this run.
2
Check and record D for U(VI) at 1.0, 1.5, 2.0 and 6.0 M, Pu(IV) at 3.0 M, and Am(III) at 3.0 M. Use the interpolation rule for acids between the measured points. Check the acid at which D_U is highest and explain the fall at high acid.
3
Compare β at 1, 3 and 6 M. State which acid gives the best uranium–americium separation in a single contact.
4
GraduateA plant needs at least 99.9% uranium recovery in 3 contacts (r = 1) and a decontamination factor from americium of at least 20, 25 or 30. For each target, check the width of the acid window that meets both conditions, record its limits in Table D, and explain why the window shrinks as the DF target rises.

Simulation: Extraction Bench, Ion-Exchange Column, and Design Graphs

Radiochemical Separations Virtual LabSet up the equipment, work out your answer, then Check

In the PUREX process, uranium(VI) and plutonium(IV) are extracted from nitric acid into tributyl phosphate (TBP), while americium and fission products such as caesium stay in the aqueous phase. Part A uses this work area.

Drag to orbit · scroll to zoom. 3D separatory funnel: the organic phase (30% TBP in dodecane) floats on the nitric acid phase. The organic layer turns yellow as uranyl nitrate is extracted, and each contact's extract is collected in a flask.

Setup

Readings

Tracer test U (org / aq, cps per mL)—
Tracer test Am (org / aq, cps per mL)—
Tracer test Cs (org / aq, cps per mL)—
Phase ratio r = V_org / V_aq—

D = (activity per mL in organic) / (activity per mL in aqueous). Single contact: E = Dr/(1 + Dr). After n contacts with fresh solvent the aqueous keeps (1 + Dr)⁻ⁿ.

Work it out, then check

Table A: your solvent extraction record
SpeciesHNO₃ (M)V_org (mL)nDE, one contact (%)Left after n (%)DF (U/Am)

A strontium-selective extraction-chromatography resin holds Sr-90 strongly in nitric acid while its daughter Y-90 passes through. Analysts use it to measure Sr-90 in waste and environmental samples. Part B uses this work area.

Drag to orbit · scroll to zoom. 3D extraction-chromatography column with a fraction collector. Press Run elution to collect fractions; the board plots the activity of yttrium-90 and strontium-90 against eluate volume.

Setup

Readings

Kd of Sr (mL/g)—
Kd of Y (mL/g)—
Bed density; free-volume fraction—
Elution run—

Bed volume = m/ρ. Free column volume V₀ = 0.65 × bed volume. Retention volume V_R = V₀ + Kd × m. Safe load volume = 50% of V_R for Sr (training rule).

Work it out, then check

Table B: your column record
HNO₃ (M)m (g)Bed (mL)V₀ (mL)V_R Sr (mL)V_R Y (mL)Sr (bed volumes)Load (mL)

Repeated contacts with fresh solvent remove more solute each time, but the gain depends on the extraction factor E = D × r. Part C uses this work area.

Fraction of solute left in the aqueous phase against the number of batch contacts with fresh solvent, on a logarithmic axis, for several distribution ratios at your phase ratio. Your D is highlighted and the dashed line is your target.

Show the plotted values

Setup

Readings

Extraction factor E = Dr—
Left after one contact—
Target—

Batch: left after n contacts = 100/(1 + Dr)ⁿ %. Countercurrent battery of N stages using one solvent volume (Kremser): fraction left φ = (E − 1)/(Eᴺ⁺¹ − 1).

Work it out, then check

Table C: your multiple-contact record
DrnLeft after n (%)Target (%)Batch contacts neededCountercurrent stages N

In TBP extraction, U(VI) and Pu(IV) form neutral nitrate complexes and their D rises with nitric acid until acid competition takes over. Am(III) and Cs(I) stay low. Part D uses this work area.

Distribution ratios of U(VI), Pu(IV), Am(III) and Cs(I) between 30% TBP and nitric acid against acid concentration (logarithmic D axis). The vertical line marks your acid; the dashed line marks D_U = 9.

Show the plotted values

Setup

Readings

Measured points—
Between points—
Recovery requirement—

Simplified training data for 30% TBP at room temperature. Between measured points, log D varies linearly with log [HNO₃].

Work it out, then check

Table D: your acid-dependence record
SpeciesHNO₃ (M)Dβ (U/Am)DF targetWindow (M)

These immersive 3D work areas and interactive graph work areas are the main version; the accessible copy delivers the same set-up, work-out, and check exercises with native controls and screen-reader announcements.

Team Questions

Question 1. After a U-233 tracer test with 10 mL of each phase, a 1 mL organic aliquot gives 4807.7 cps and a 1 mL aqueous aliquot gives 192.3 cps. What is the distribution ratio D?
Question 2. With that D and equal volumes of organic and aqueous, what percentage of the uranium is extracted in one contact?
Question 3. What percentage of the uranium is left in the aqueous after two contacts, each with an equal volume of fresh solvent?
Question 4. In the same acid, D for Am(III) is 0.020. For one contact at r = 1, what is the decontamination factor of uranium from americium?
Question 5. A column holds 2.0 g of Sr resin with a bed density of 0.35 g/mL and a free-volume fraction of 0.65. What is the free column volume V₀, in mL?
Question 6. In 8 M HNO₃ the Kd of Sr on this resin is 90 mL/g. What is the retention volume of Sr on the column in Question 5, in mL?
Question 7: Challenge. A 100 mL water sample in 8 M HNO₃ must be loaded. Using the 50% load rule, what is the minimum resin mass needed, in g?

Example Lab Report

Sample report showing the expected format and level of detail. Use it as a guide for your own submission, and include labelled screenshots of each setup.

Radiochemical Separations: Solvent Extraction and Ion Exchange

Nuclear Chemistry | Section: [Your Section] | Date: [Date]

Lab Members: [Names of all members present]

Purpose

To measure distribution ratios for U(VI), Am(III), and Cs(I) in 30% TBP, predict the extraction and decontamination achieved by single and multiple contacts, design a strontium-resin column that separates Sr-90 from Y-90, compare batch and countercurrent extraction, and choose a process acid window from distribution-ratio curves.

Theory

The fraction extracted in one contact is Dr/(1 + Dr); after n fresh-solvent contacts (1 + Dr)⁻ⁿ stays in the aqueous. On a column a species elutes at V_R = V₀ + Kd·m.

E = Dr/(1 + Dr)  ·  left = (1 + Dr)⁻ⁿ  ·  DF = E_U/E_Am  ·  V_R = V₀ + Kd·m

Table A: Solvent Extraction Undergraduate

SpeciesHNO₃ (M)V_org (mL)nDE, one contact (%)Left after n (%)DF (U/Am)
U(VI)310012596.153.84649.04
U(VI)310032596.150.00569017.34
U(VI)11001888.8911.1189.78
U(VI)610012095.244.76232.70
U(VI)35012592.597.40793.52
Am(III)310010.021.96198.0449.04
Cs(I)310010.0010.099999.9049.04

Table B: Sr Resin Column Undergraduate

HNO₃ (M)m (g)Bed (mL)V₀ (mL)V_R Sr (mL)V_R Y (mL)Sr (bed volumes)Load (mL)
82.05.713.71183.76.7132.191.9
84.011.437.43367.413.4332.1183.7
32.05.713.7183.75.3114.641.9
34.011.437.43167.410.6314.683.7

Table C: Batch Contacts and Countercurrent Stages Upper undergraduateGraduate step

DrnLeft after n (%)Target (%)Batch contacts neededCountercurrent stages N
2133.704155.66
2230.8133.12
5130.4630.144.15
100.530.4630.144.15
11312.51799.00
0.51329.63106not reachable

Left = 100/(1 + Dr)ⁿ %; batch contacts n ≥ ln(1/f)/ln(1 + Dr). Graduate step: Kremser N = ln[(E − 1)/φ + 1]/ln E − 1 with E = Dr. With E = 2, a 1% target needs 5 batch contacts (5 solvent volumes) or 5.66 countercurrent stages (6 stages, 1 solvent volume). With E = 1, N = 1/φ − 1 = 99 stages. With E = 0.5 a countercurrent battery can never leave less than 50%, so a 10% target is not reachable.

Table D: Distribution Ratio against Nitric Acid (simplified training data) Upper undergraduateGraduate step

SpeciesHNO₃ (M)Dβ (U/Am)
U(VI)1.08800
U(VI)1.512.18943.2
U(VI)2.016.421060
U(VI)3.0251250
U(VI)6.020666.7
Pu(IV)3.0121250
Am(III)3.00.021250

D_U peaks near 3 M. Graduate step: ≥ 99.9% U recovery in 3 contacts needs D_U ≥ 9, which holds from 1.12 M. DF ≥ 20 holds up to 2.37 M (window 1.25 M); DF ≥ 25 up to 1.65 M (window 0.52 M); DF ≥ 30 up to 1.22 M (window 0.10 M).

Discussion

Uranium extracted strongly at all three acid strengths, with the highest D at 3 M. Americium and caesium stayed almost entirely in the aqueous raffinate. A single contact recovered 96% of the uranium with a DF of 49 from americium. Three contacts left only 0.006% of the uranium behind, but the DF fell to 17, because each fresh portion of solvent also carried a little more americium. This is why PUREX uses a counter-current extraction section followed by a scrub section. Halving the solvent volume lowered the recovery to 93% but doubled the DF, showing the trade-off between recovery and purity.

On the column, Y-90 eluted almost at the free column volume while Sr-90 was held for 32 bed volumes in 8 M HNO₃. In 3 M acid the Sr retention fell to 15 bed volumes, so 8 M is the better load acid. Doubling the resin mass doubled every volume but did not change the bed-volume figure. The Sr fraction is stripped later with dilute acid and counted after Y-90 ingrowth.

The multiple-contact graph showed that what matters is the extraction factor E = Dr, not D alone: D = 10 at r = 0.5 gave exactly the same curve as D = 5 at r = 1. Each extra batch contact with fresh solvent removes the same fraction again, so the curves are straight on a logarithmic axis. The acid-dependence graph showed why plants run near 3 M nitric acid: D_U is at its peak there, so uranium and plutonium extract well while americium and caesium stay in the raffinate, and β was largest near 3 M.

The graduate steps turned these graphs into design decisions. A countercurrent battery reached the same 1% target with one solvent volume instead of five, at the cost of about one extra stage; this is why plants use mixer-settler banks or pulsed columns rather than repeated batch contacts. When E fell to 1 or below, countercurrent staging lost its advantage or could not reach the target at all. The acid window for 99.9% recovery and a high DF was narrow, and it shrank from about 1.25 M to about 0.10 M as the DF target rose from 20 to 30. A real flowsheet adds a scrub section to wash americium back out of the solvent, which relaxes this limit.

Conclusion

Distribution ratios and distribution coefficients predict how a radionuclide divides between phases, and they let the chemist design for both recovery and decontamination before any radioactive material is handled.

Practice Questions

Show all work and include units.

Question 1
D for Pu(IV) in 3 M HNO₃ with 30% TBP is about 15. What fraction is extracted in one contact with half a volume of solvent (r = 0.5)?
Hint: Dr = 7.5.
Question 2
Show that one contact with 200 mL of solvent extracts less than two contacts with 100 mL each, for D = 2 and 100 mL of aqueous.
Hint: compare (1 + 4)⁻¹ with (1 + 2)⁻².
Question 3
Why does extraction of U(VI) by TBP increase with nitrate concentration at first and then fall at high HNO₃?
Hint: salting out versus competition for TBP.
Question 4
A 5 g Sr resin column is used in 8 M HNO₃. Find V₀, V_R for Sr, and the safe load volume.
Hint: use ρ = 0.35 g/mL and ε = 0.65.
Question 5
After the Sr fraction is separated, why must the analyst wait about two weeks before counting it for Sr-90?
Hint: Y-90 has a 64 h half-life.
Question 6
Name two ways to raise the decontamination factor of uranium from fission products in a PUREX plant.
Hint: think about scrubbing and the number of cycles.
© 2026 E2 Innovations LLC / Virginia Research Institute. All rights reserved. Licensed for use on E2 Innovations and VRI sites only — not for redistribution or reuse in other courses. Contact info@e2innovations.ai.