← Back to Virtual Labs|Reactivity Feedback, Power Peaking, and Decay Heat
Nuclear Engineering Technology · Reactor Operations: Feedback, Thermal Limits, and Shutdown Cooling

Reactivity Feedback, Power Peaking, and Decay Heat

Work as a reactor engineer supporting a 3411 MWt pressurized-water reactor. Raise power and work out how the moderator and fuel temperature feedback eat into reactivity, and how much boron must be diluted to hold the reactor critical. Then calculate core thermal power from the neutron flux, find the hot-spot linear heat rate from the power peaking factors, and check it against the technical specification limit. Finally, trip the reactor and size the residual heat removal flow needed to carry away decay heat. Two graph work areas then turn the same physics into planning tools: decay-heat curves for deciding how long one cooling train must wait before it can carry the core alone, and a power-defect graph for planning the boron change for a load-following power maneuver. In every part you work out the answer yourself, then check it.

Theory: Feedback, Thermal Limits, and Decay Heat

Why Feedback Matters

A power reactor is not held critical by its control rods alone. As power rises, the coolant and fuel heat up, and that heating changes k. Designers make sure these reactivity coefficients are negative, so that any rise in power or temperature removes reactivity and the reactor tends to return to where it was. This inherent stability is required by NRC General Design Criterion 11. It also means that operators must add positive reactivity, usually by diluting soluble boron, to raise power and keep the reactor critical.

Moderator and Fuel Temperature Coefficients

The moderator temperature coefficient (MTC) describes how reactivity changes with coolant temperature. Hot water is less dense, so the lattice becomes less moderated; in an under-moderated PWR this lowers p more than it raises f, and the MTC is negative. Dissolved boron leaves the core with the expanding water, which pushes the MTC towards positive, so the MTC is least negative at the beginning of cycle (high boron) and most negative at end of cycle (low boron). The fuel temperature (Doppler) coefficient comes from the broadening of U-238 resonances as fuel heats, which increases resonance capture and lowers p. It acts instantly, because the fuel heats before the coolant does.

Feedback and the Power Defect Δρ_mod = MTC × ΔT_mod     Δρ_Doppler = FTC × ΔT_fuel
Power defect = Δρ_mod + Δρ_Doppler   (from hot zero power to power P)
Boron change to stay critical: Δppm = power defect / boron worth
Negative power defect → dilute boron (or withdraw rods) to raise power

Core Thermal Power from the Neutron Flux

Every fission releases about 200 MeV, of which about 3.2 × 10⁻¹¹ J is recovered as heat in the core. The fission rate per cubic centimetre is Σ_fφ, so the thermal power of the whole core follows from the core-average flux and volume.

Thermal Power and Linear Heat Rate P = (3.2 × 10⁻¹¹ J) × Σ_f × φ_avg × V     V = πR²H
q′_avg = P / (N_rods × L_rod)   (W/cm)
The flux, and so the power, is not uniform: it peaks in the middle

Power Peaking Factors

In a bare cylinder the flux falls from the centre to the edges as a Bessel function J₀ radially and a cosine axially. The peaking factor is the ratio of the peak to the average. The hot spot sets the thermal limits, so the core must be designed and operated so that the peak linear heat rate stays below the technical specification limit (typically about 18 kW/ft, 590 W/cm) and fuel centreline melting and cladding damage are avoided. Fuel managers flatten the power with low-leakage loading patterns (fresh fuel interspersed with burned fuel, burned fuel on the periphery) and burnable absorbers; in-core detectors measure the real peaking factors.

Peaking Factors F_R = peak/average radially (2.316 for a bare J₀ shape)    F_Z = peak/average axially (π/2 = 1.571 for a cosine)
F_Q = F_R × F_Z     q′_max = F_Q × q′_avg
q′_max must stay below the linear heat rate limit

Decay Heat and Shutdown Cooling

When a reactor trips, fission stops within seconds, but the fission products already in the fuel keep decaying. Their beta and gamma energy, the decay heat, is about 6 to 7% of full power just after shutdown, about 1% after an hour, and still a few tenths of a percent after a month. It must be removed continuously; losing it was the cause of fuel damage at Three Mile Island and Fukushima Daiichi. The Way–Wigner correlation gives a good estimate. The residual heat removal (RHR) system carries the heat to a heat exchanger.

Way–Wigner Decay Heat and Heat Removal P_d / P₀ = 0.0622 [ t^(−0.2) − (t + T)^(−0.2) ]   (t = time since shutdown, T = operating time, both in s)
Q = ṁ c_p ΔT  →  ṁ = P_d / (c_p ΔT)
Decay heat falls slowly: cooling must continue for weeks

Data Used in This Lab

QuantityBOCEOC
Soluble boron at full powerabout 1200 ppmabout 50 ppm
Moderator temperature coefficient−10 pcm/°C−45 pcm/°C
Doppler (fuel temperature) coefficient−3 pcm/°C−3 pcm/°C
Differential boron worth−8 pcm/ppm−10 pcm/ppm
Core dataValueCore dataValue
Rated thermal power3411 MWtCore radius; height170 cm; 366 cm
Fuel rods; active length50 952; 365.8 cmCore-average Σ_f0.10 cm⁻¹
Energy recovered per fission3.2 × 10⁻¹¹ JLinear heat rate limit590.6 W/cm (18.0 kW/ft)
T_avg programme291.7 + 0.161 P °CSpecific heat of coolant4.2 kJ/kg·°C

Values are typical of a four-loop Westinghouse-type PWR and follow the DOE Fundamentals Handbook (Nuclear Physics and Reactor Theory; Heat Transfer, Fluid Flow and Thermodynamics) and the NRC Reactor Concepts Manual. Real coefficients vary with burnup, boron, and power, and are supplied for each cycle in the plant's core operating limits report.

Operations

Reactor operators dilute boron as power rises and borate as it falls, and track the power defect on every power change.

Reactor engineering

Engineers check the peaking factors from in-core flux maps against the core operating limits report every month.

Safety analysis

Decay-heat curves size the RHR, emergency core cooling, and spent fuel pool cooling systems.

Planning with Decay-Heat and Power-Defect Graphs

Operators and engineers plan with graphs of these same equations. A decay-heat curve for the actual operating history shows when the decay heat falls below the capacity of one cooling train, which sets how long redundant trains or other heat sinks must stay available after shutdown. Because long-lived fission products build up only over a long run, the operating history makes little difference in the first minutes but a large one after days. A power-defect graph is used for load following: the feedback reactivity changes linearly with power, so the boron change for a planned maneuver is the power defect per percent power times the change in power, divided by the boron worth.

Apparatus

The plant systems and instruments used to manage feedback, thermal limits, and decay heat. In the simulation these are modelled for you, and the readings correspond to what each would show.

Reactor coolant system
The vessel, hot and cold legs, pumps, and steam generators; RTDs on each leg give T_hot and T_cold.
RTD
RTDs and T_avg
Narrow-range RTDs measure loop temperatures; T_avg = (T_hot + T_cold)/2 is controlled to a programme that rises with power.
H₃BO₃water
Chemical and volume control
Adds boric acid (borate) or pure makeup water (dilute) to change the boron concentration in ppm.
In-core flux mapping
Movable fission chambers or fixed in-core detectors map the flux and give the measured F_R, F_Z, and F_Q.
RHR pump and heat exchanger
Removes decay heat after shutdown by passing reactor coolant through a heat exchanger cooled by component cooling water.
COLR
Core operating limits report
Lists each cycle's coefficients, peaking-factor limits, and boron worths used in these calculations.

Instructions: Running the Virtual Experiment

You are the reactor engineer on shift. The simulation has three immersive 3D work areas and two graph work areas. The parts build from undergraduate work in Parts A, B, and C to graduate-level analysis in the last step of Parts D and E; the level of each part is shown beside its title. In each one you set the plant conditions, read the instruments, work out the answer yourself, enter it, and press Check. Record every reading and calculation in your lab report tables (modelled in the Example Report), with a labelled screenshot of each setup. Drag in any 3D view to orbit, and scroll to zoom. Use the data tables in the Theory section.

Part A: Power Defect and Boron Dilution (3D Power Feedback)Undergraduate
1
Open Simulation → 3D Power Feedback. Choose Beginning of cycle and set the power to 50%. Read ΔT_mod and ΔT_fuel. Choose Predict: moderator feedback, calculate Δρ_mod = MTC × ΔT_mod with its sign, and check it. Then do the same for Predict: Doppler feedback.
2
Choose Predict: total power defect and check it. Then choose Predict: boron dilution, calculate the ppm of boron to dilute to stay critical, and check it. Press Record this run.
3
Repeat at 100%, then repeat both powers at End of cycle. Record all four cases in Table A and explain why the power defect is larger at end of cycle.
Part B: Core Power and Hot-Spot Linear Heat Rate (3D Core Power Map)Undergraduate
1
Open 3D Core Power Map. Choose Uniform fresh loading and set φ = 3.20 × 10¹³. Choose Predict: core thermal power, calculate P = 3.2×10⁻¹¹ Σ_f φ V in MW, and check it. Then check q′_avg.
2
Check F_Q and q′_max. Compare q′_max with the 590.6 W/cm limit, look at where the red hot spot sits in 3D, and press Record this run.
3
Switch to the Low-leakage flattened loading at the same flux and repeat. Then return to the uniform loading and find the highest flux, and the power, that keeps q′_max within the limit. Record all runs in Table B.
Part C: Decay Heat and RHR Flow (3D Shutdown Cooling)Undergraduate
1
Open 3D Shutdown Cooling. Choose an operating time of 1 year, a time since shutdown of 1 hour, and ΔT = 25 °C. Choose Predict: decay heat fraction, calculate it with the Way–Wigner equation, and check it.
2
Check the decay heat in MW and the RHR mass flow needed. Press Record this run.
3
Repeat for 10 s, 1 minute, 8 hours, 1 day, 1 week, and 30 days. Record them in Table C and plot P_d/P₀ against time on log–log axes. Explain why RHR cooling must continue for weeks after shutdown.
Part D: Decay-Heat Planning (Graph: Decay Heat Curves)Upper undergraduateGraduate step
1
Open Graph: Decay Heat Curves. Choose a 1 year history, a 20 MW train, and 1 hour after shutdown. Read where the 1-year curve crosses the capacity line, then check the time for decay heat to fall to one train capacity. Check the decay-heat ratio (3-year run ÷ 30-day run) at 1 hour. Press Record this run.
2
Check and record: a 1-year history with a 30 MW train at 1 day and with a 10 MW train at 30 days; a 30-day history with a 20 MW train at 1 week; and a 3-year history with a 20 MW train at 8 hours. Record all runs in Table D.
3
From the graph, explain why the three curves almost overlap at first and separate later. Take a labelled screenshot of the curves for your report.
4
GraduateIntegrate the Way–Wigner equation to find the decay energy released in the next 24 h. Check it for a 1-year run starting 1 hour and 1 day after shutdown, and for a 3-year run starting 1 hour after shutdown. Write the results under Table D and explain what this energy would do to the coolant inventory if cooling were lost.
Part E: Load-Following Boron Changes (Graph: Power Defect)Upper undergraduateGraduate step
1
Open Graph: Power Defect. Choose BOC, a starting power of 100%, and a final power of 50%. Check the feedback reactivity change and the boron change (a negative answer means borate). Press Record this run.
2
Repeat for 50% → 100% and 30% → 90% at BOC, then for the same three changes at EOC. Record all six in Table E.
3
Use the graph to explain which part of the power defect, moderator or Doppler, changes between BOC and EOC, and why the boron change for the same maneuver is almost the same at both points.
4
GraduateDoppler broadening grows as the square root of the absolute fuel temperature. Check the feedback change with a √T Doppler law calibrated at 100% for 100% → 50% and 30% → 90% at BOC, and 0% → 30% at EOC. Write the results under Table E and compare them with the linear model.

Simulation: Power Ascension Feedback, Core Peaking, Shutdown Cooling, and Planning Graphs

Reactivity Feedback and Decay Heat Virtual LabSet up the equipment, work out your answer, then Check

The reactor is critical at hot zero power (0%, T_avg = 291.7 °C). Raise the power. The average coolant temperature follows the programme T_avg = 291.7 + 0.161 P °C, and the average fuel temperature rises to T_fuel = T_avg + 6.0 P °C (P in %). Part A uses this work area.

Drag to orbit · scroll to zoom. 3D reactor coolant system: the vessel with its hot leg (red) and cold leg (blue), a fuel-rod thermometer, and the boron makeup tank. Raising power heats the coolant and the fuel; the temperature tags and colours update.

Setup

Readings

Average coolant T_avg—
Average fuel temperature—
ΔT moderator from 0%—
ΔT fuel from 0%—
Moderator temperature coefficient—
Doppler (fuel temperature) coefficient—
Differential boron worth—

Coefficients are per °C. Boron worth is negative: adding boron removes reactivity, diluting it adds reactivity.

Work it out, then check

Table A: your power defect record
CyclePower (%)ΔT_mod (°C)ΔT_fuel (°C)Δρ_mod (pcm)Δρ_Doppler (pcm)Power defect (pcm)Dilution (ppm)

A 3411 MWt-class core: radius 170 cm, height 366 cm, 50 952 fuel rods each 365.8 cm long. Set the average thermal flux and the loading pattern, work out the core power and the hot-spot linear heat rate, and compare it with the limit. Part B uses this work area.

Drag to orbit · scroll to zoom. 3D core power map: the core is drawn as rings and layers coloured by local power, from blue (low) through yellow to red (high). The hottest spot is at the centre of a bare core; a flattened loading spreads the power more evenly.

Setup

Readings

Core-average Σ_f—
Core volume V—
Radial peaking factor F_R (in-core detectors)—
Axial peaking factor F_Z (in-core detectors)—
Linear heat rate limit—

Each fission releases 3.2 × 10⁻¹¹ J. A uniform bare core has F_R = 2.316 (Bessel J₀ shape) and F_Z = 1.571 (cosine shape).

Work it out, then check

Table B: your core power and peaking record
Loadingφ (× 10¹³)P (MW)q′_avg (W/cm)F_Qq′_max (W/cm)Within 590 W/cm?

The reactor has tripped from full power after a long run. Fission has stopped, but the decay of fission products keeps producing heat. Choose the time since shutdown and size the residual heat removal (RHR) flow. Part C uses this work area.

Drag to orbit · scroll to zoom. 3D residual heat removal loop: after a reactor trip, the pump drives coolant from the vessel through the RHR heat exchanger and back. The core glow fades as decay heat falls, and the flow markers speed up with the flow rate you set.

Setup

Readings

Rated thermal power P₀—
Operating time T—
Time since shutdown t—
Specific heat of coolant c_p—

Way–Wigner decay heat correlation, valid from about 10 s to 100 days after shutdown.

Work it out, then check

Table C: your decay heat record
T (operation)t (after shutdown)P_d/P₀P_d (MW)ΔT (°C)ṁ (kg/s)

Decay heat depends on how long the reactor ran before shutdown. After a long run, more long-lived fission products have built up, so decay heat stays higher for longer. Part D uses this work area.

Decay heat against time after shutdown (logarithmic axes) for three operating histories, with the capacity of one cooling train. The dot is the time you selected; the dashed vertical line marks when the chosen history falls to the train capacity.

Show the plotted values

Setup

Readings

Rated power P₀—
Decay heat now (this history)—
Train capacity—

Way–Wigner: P_d = 3411 × 0.0622 [ t^(−0.2) − (t + T)^(−0.2) ] MW. Read crossing times from the graph, then refine by trial.

Work it out, then check

Table D: your decay-heat planning record
HistoryTrain capacity (MW)Time to reach capacity (h)Time after shutdownRatio 3 y ÷ 30 d

Plants that follow grid demand change power during the day. Every power change shifts the coolant and fuel temperatures, so the feedback reactivity changes and boron must be adjusted to keep the reactor critical. Part E uses this work area.

Power defect against power level for the chosen point in the cycle, split into the moderator and Doppler parts. The two dots mark the starting and final power of your load change.

Show the plotted values

Setup

Readings

MTC; FTC—
Boron worth—
ΔT_mod, ΔT_fuel per % power—
Power defect per % power—

Power defect at P = (MTC × 0.161 + FTC × 6.161) × P. Reactivity change = defect(final) − defect(start).

Work it out, then check

Table E: your load-change record
CycleStart (%)Final (%)Δρ feedback (pcm)Boron change (ppm, + dilute)

These immersive 3D work areas and interactive graph work areas are the main version; the accessible copy delivers the same set-up, work-out, and check exercises with native controls and screen-reader announcements.

Team Questions

Question 1. The moderator temperature coefficient is −40 pcm/°C. T_avg rises by 5.0 °C. What reactivity change results, in pcm (include the sign)?
Question 2. From hot zero power to full power, T_avg rises 16 °C and the average fuel temperature rises 600 °C. With MTC = −20 pcm/°C and FTC = −3.0 pcm/°C, what is the power defect in pcm?
Question 3. The boron worth is −8.0 pcm/ppm. How many ppm must be diluted to make up the power defect in Question 2?
Question 4. A bare cylindrical core has F_R = 2.32 and F_Z = 1.57. What is the total peaking factor F_Q?
Question 5. A core has q′_avg = 183 W/cm and a measured F_Q = 2.20. What is the peak linear heat rate, in W/cm?
Question 6. A reactor operated for 1 year (3.156 × 10⁷ s) and shut down 1 hour ago. Using the Way–Wigner equation, what is the decay heat as a percentage of full power?
Question 7: Challenge. An RHR heat exchanger must remove 20 MW of decay heat with a 25 °C temperature drop. With c_p = 4.2 kJ/kg·°C, what mass flow is needed, in kg/s?

Example Lab Report

Sample report showing the expected format and level of detail. Use it as a guide for your own submission, and include labelled screenshots of each setup.

Reactivity Feedback, Power Peaking, and Decay Heat

Nuclear Engineering Technology | Section: [Your Section] | Date: [Date]

Lab Members: [Names of all members present]

Purpose

To calculate the moderator and Doppler feedback and the power defect for a power ascension at beginning and end of cycle, and the boron dilution needed to stay critical; to calculate core thermal power, average and peak linear heat rates, and compare them with the technical specification limit; to calculate decay heat after shutdown and the RHR flow needed to remove it; and to use decay-heat and power-defect graphs to plan cooling-train capacity and boron changes for load following.

Theory

Feedback is Δρ = MTC ΔT_mod + FTC ΔT_fuel, and the boron change to stay critical is the power defect divided by the boron worth. Core power is P = 3.2×10⁻¹¹ Σ_fφV, the hot-spot linear heat rate is q′_max = F_R F_Z q′_avg, and decay heat follows P_d/P₀ = 0.0622[t^(−0.2) − (t + T)^(−0.2)], removed at ṁ = P_d/(c_pΔT).

Δρ = MTC ΔT_m + FTC ΔT_f  ·  P = 3.2×10⁻¹¹ Σ_fφV  ·  q′_max = F_Q q′_avg  ·  ṁ = P_d/(c_pΔT)

Table A: Power Defect and Boron Dilution (from 0% power) Undergraduate

CyclePower (%)ΔT_mod (°C)ΔT_fuel (°C)Δρ_mod (pcm)Δρ_Doppler (pcm)Power defect (pcm)Dilution (ppm)
BOC508.05308.1−80.5−924.2−1004.7125.6
BOC10016.10616.1−161.0−1848.3−2009.3251.2
EOC508.05308.1−362.3−924.2−1286.4128.6
EOC10016.10616.1−724.5−1848.3−2572.8257.3

Sample calculation (BOC, 100%): Δρ_mod = −10 × 16.10 = −161.0 pcm; Δρ_Doppler = −3 × 616.1 = −1848.3 pcm; defect = −2009.3 pcm; dilution = −2009.3 / −8 = 251.2 ppm.

Table B: Core Power and Peaking Undergraduate

Loadingφ (× 10¹³)P (MW)q′_avg (W/cm)F_Qq′_max (W/cm)Within 590.6 W/cm?
Uniform (bare)3.203403182.63.638664no
Flattened3.203403182.62.175397yes
Uniform (bare)2.802977159.73.638581yes

Sample calculation: V = π × 170² × 366 = 3.323×10⁷ cm³; P = 3.2×10⁻¹¹ × 0.10 × 3.2×10¹³ × 3.323×10⁷ = 3.403×10⁹ W; q′_avg = 3.403×10⁹ / (50 952 × 365.8) = 182.6 W/cm.

Table C: Decay Heat after 1 Year at 3411 MWt (ΔT = 25 °C) Undergraduate

t after shutdownP_d/P₀P_d (MW)ṁ (kg/s)
10 s0.03728127.151211.0
1 minute0.0254686.84827.0
1 hour0.0101334.54328.9
8 hours0.0060120.50195.3
1 day0.0044415.14144.2
1 week0.002388.1277.3
30 days0.001314.4642.5

Table D: Decay-Heat Planning (one cooling train) Upper undergraduateGraduate step

HistoryTrain capacity (MW)Time to reach capacity (h)Time after shutdownRatio 3 y ÷ 30 d
1 year208.781 hour1.188
1 year301.791 day1.516
1 year1091.9930 days3.984
30 days204.141 week2.247
3 years2011.328 hours1.350

Crossing times found by trial: P_d = 3411 × 0.0622 [t^(−0.2) − (t + T)^(−0.2)] = capacity. Include a screenshot of the decay-heat curves with the capacity line.

Graduate step: integrating Way–Wigner, E = 3411 × 0.0622 × [t^0.8 − (t + T)^0.8]/0.8 between t and t + 24 h. After a 1-year run the next 24 h release 1672.3 GJ starting at 1 hour and 1169.1 GJ starting at 1 day; after a 3-year run, 1786.6 GJ starting at 1 hour. 1672 GJ would boil off roughly 740 t of water at 2.26 MJ/kg.

Table E: Load-Following Power Changes Upper undergraduateGraduate step

CycleStart (%)Final (%)Δρ feedback (pcm)Boron change (ppm, + dilute)
BOC100501004.6−125.6
BOC50100−1004.6125.6
BOC3090−1205.6150.7
EOC100501286.4−128.6
EOC50100−1286.4128.6
EOC3090−1543.7154.4

Power defect per % power: BOC −20.093 pcm/%, EOC −25.728 pcm/%. Δppm = Δρ / boron worth.

Graduate step: with a √T Doppler law calibrated at 100% (T_f(P) = 564.85 + 6.161P K), the feedback change is +921.1 pcm for 100% → 50% at BOC (linear: +1004.6), −1156.3 pcm for 30% → 90% at BOC (linear: −1205.6), and −847.6 pcm for 0% → 30% at EOC (linear: −771.8). The boron change for 0% → 30% at EOC becomes 84.8 ppm of dilution instead of 77.2 ppm.

Discussion

Both coefficients were negative, so raising power removed reactivity and boron had to be diluted by about 250 ppm to reach full power. The Doppler effect supplied most of the power defect, because the fuel heats by hundreds of degrees while the coolant heats by only 16 °C. At end of cycle the moderator coefficient was four and a half times more negative, because the low boron concentration no longer offsets the loss of moderation, so the power defect grew from −2009 to −2573 pcm. A large negative MTC also means a cooldown, such as a steam-line break, adds a lot of positive reactivity at end of cycle.

A uniform fresh core at rated flux put the hot spot at 664 W/cm, above the 590.6 W/cm limit, even though the average was only 183 W/cm. The flattened low-leakage loading lowered F_Q from 3.64 to 2.18 at the same power, bringing the hot spot to 397 W/cm. With a uniform loading, power would have to be held to about 2977 MW (87%). Decay heat fell from 3.7% of full power at 10 s to 1.0% at 1 hour and 0.13% at 30 days. Even after a month, 4.5 MW must still be removed, which is why shutdown cooling and spent fuel cooling run continuously.

The decay-heat curves showed that operating history matters little in the first minutes but a great deal later. At 1 hour the 3-year core made only 1.19 times the decay heat of the 30-day core, but at 30 days it made 3.98 times as much, because long-lived fission products only build up over a long run. After a 1-year run, one 20 MW train could carry the core alone from about 8.8 hours, but a 10 MW train only from about 92 hours (3.8 days). The power-defect graph showed a straight line for each part of the cycle, so the boron change for a load change is simply the power defect per percent times the change in power. Dropping from 100% to 50% needed 126 ppm of boration at BOC and 129 ppm at EOC. The EOC value is only slightly larger because the steeper power defect is largely offset by the higher boron worth.

The graduate steps refined both simple pictures. Integrating the decay-heat curve showed that the first day after a trip from a long run still releases about 1.7 TJ, enough to boil roughly 740 tonnes of water if all cooling were lost, which is why cooling is protected by redundant trains. Replacing the linear Doppler model with the √T law left the full-power defect unchanged but moved more of it to low power: the 0% → 30% change gained about 76 pcm of negative feedback, and the 100% → 50% change lost about 83 pcm. Operators therefore expect proportionally more dilution during the first part of a power ascension than a straight-line estimate predicts.

Conclusion

Negative feedback coefficients make the reactor self-limiting but require boron dilution to raise power. Power peaking, not average power, sets the thermal limit, and core loading patterns are designed to flatten it. Decay heat remains significant for weeks, and the RHR flow must be sized for it.

Practice Questions

Show all work and include units. Use the data tables in the Theory section.

Question 1
At end of cycle, the reactor is reduced from 100% to 60% power. Find the reactivity added by feedback and the boron change (borate or dilute, in ppm) needed to stay critical at constant rod position.
Hint: feedback now adds reactivity, so boron must be added.
Question 2
Explain why the MTC becomes more negative from beginning to end of cycle, and why a positive MTC is not allowed at power.
Hint: what happens to the dissolved boron when the water expands?
Question 3
A 1000 MWt core has 29 000 rods of 366 cm and F_Q = 2.5. Find q′_avg and q′_max in W/cm and kW/ft (1 kW/ft = 32.8 W/cm).
Hint: q′_avg = P/(N L).
Question 4
Show that a cosine axial flux shape cos(πz/H) over −H/2 ≤ z ≤ H/2 has a peak-to-average ratio of π/2.
Hint: average the cosine over the core height.
Question 5
Use the Way–Wigner equation to compare the decay heat 1 day after shutdown for a reactor that ran for 30 days and one that ran for 3 years. Explain the difference.
Hint: long-lived fission products build up only with long operation.
Question 6: Challenge
A spent fuel pool holds a full core offload 3 days after shutdown (P₀ = 3411 MWt, 1 year of operation). The pool holds 1.5 × 10⁶ kg of water at 40 °C. If pool cooling is lost, how long until the pool reaches 100 °C?
Hint: t = m c_p ΔT / P_d, assuming P_d stays roughly constant over that time.