Calculate renewable energy output in four experiments: solar panel power, wind turbine power (the v³ law), capacity factor, and energy delivered over time. In each, predict the result yourself, then run the bench and check. Units: W, kW, percent, kWh.
Theory: Renewable Energy Output
Turning sun and wind into power
A solar panel's output depends on its area, the sunlight falling on it, and its efficiency. A wind turbine's output depends on the cube of the wind speed. Both deliver less than their rated maximum on average — captured by the capacity factor.
Key relationships
Solar: P = A × irradiance × efficiency | Wind: P = k × v³ | Capacity factor = (average / rated) × 100 | Energy: E = P × t
Wind power scales as v³, so a small rise in wind speed is a big rise in power.
The cube law
Because wind power goes as the cube of speed, doubling the wind gives eight times the power. This is why turbine siting in windy places matters so much.
Capacity factor and energy
No renewable source runs at full power all the time, so the capacity factor reports the fraction of rated output actually delivered. Multiplying power by time gives the energy in kilowatt-hours — the unit on an electricity bill.
Apparatus
The elements of a renewable-energy study. In the simulation these are modeled for you.
Solar Array
Area × irradiance × efficiency.
Wind (v³)
Power rises with the cube of speed.
Capacity Factor
Average output vs the rated maximum.
Energy (kWh)
Power multiplied by time.
Instructions
The Simulation has four experiments on tabs. In each, set the control, work out the answer yourself first, enter your prediction, and press Check. Record every run. The 3D benches can be rotated and zoomed; the graph tabs show curves.
Experiment A: Solar Panel Output
1
On the Solar tab, set the panel area. Predict P = area × 1000 × 0.2, then check.
Experiment B: Wind Turbine Power
2
On the Wind tab, set the wind speed. Predict P = 0.06 × v³, then check.
Experiment C: Capacity Factor
3
On the Capacity tab, set the average output. Predict CF = (average / 50) × 100, then check.
Experiment D: Energy = Power × Time
4
On the Energy tab, set the run time. Predict E = 4 × t, then check.
Simulation
Renewable Energy Virtual LabFour experiments — pick a tab, predict, then check.
A solar array under full sun; adding panels adds area and power. Rotate to view.
Solar Panel Output
Readout
Irradiance1000 W/m²
Efficiency0.20
Area10 m²
Power— hidden
Predict the power output (W), then check.
Turbine power versus wind speed — a steep cubic curve. The amber line marks your wind speed.
Wind Turbine Power
Readout
Constant k0.06 kW·(s/m)³
Wind speed5 m/s
Power— hidden
Predict the turbine power (kW), then check.
Capacity factor versus average output — a straight line to 100% at the rated 50 kW. The amber line marks your output.
Capacity Factor
Readout
Rated power50 kW
Average output15 kW (rated 50)
Capacity factor— hidden
Predict the capacity factor (%), then check.
A battery filling as a 4 kW source runs. Longer run time stores more energy. Rotate to view.
Energy = Power × Time
Readout
Power4 kW
Run time6 h
Energy— hidden
Predict the energy stored (kWh), then check.
Team Questions
Question 1. (A) A 10 m² array at 1000 W/m² and 0.2 efficiency produces what power?
Question 2. (A) Besides area, what two things set a panel's output?
Question 3. (B) With P = 0.06v³, what is the power at 10 m/s?
Question 4. (B) If the wind speed doubles, by what factor does the power rise?
Question 5. (C) A 50 kW turbine averages 15 kW. What is its capacity factor?
Question 6. (C) What does the capacity factor measure?
Question 7. (D) How much energy does a 4 kW source deliver in 6 hours?
Question 8. (D) Why are wind and solar called "intermittent" sources?
Renewable Energy Output — Four Experiments
Biology | Section: [Your Section] | Date: [Date]
Lab Members: [Names of all members present]
Purpose
To calculate renewable energy output: solar panel power, wind turbine power, capacity factor, and energy delivered over time.
Theory
Solar power = area × irradiance × efficiency; wind power = k·v³; capacity factor = (average/rated) × 100; and energy = power × time.
Results A — Solar
Area (m²)
Power (W)
No rows yet.
Worked example: 10 × 1000 × 0.2 = 2000 W.
Results B — Wind
Wind (m/s)
Power (kW)
No rows yet.
Worked example: 0.06 × 10³ = 60 kW.
Results C — Capacity Factor
Average (kW)
CF (%)
No rows yet.
Worked example: 15 / 50 × 100 = 30%.
Results D — Energy
Time (h)
Energy (kWh)
No rows yet.
Worked example: 4 × 6 = 24 kWh.
Discussion
Solar power scaled directly with area; wind power climbed steeply with the cube of speed; the capacity factor stayed well below 100%; and energy grew in step with run time.
Conclusion
Renewable output follows simple physics: area and sunlight for solar, the cube of speed for wind. Capacity factors below 100% and the intermittency of sun and wind are why storage and grid planning matter.
Practice Questions
1
A 25 m² array runs at 1000 W/m² and 0.2 efficiency. Find its power.
Hint: 25 × 1000 × 0.2 = 5000 W.
2
Using P = 0.06v³, compare the power at 4 m/s and 8 m/s.
Hint: 3.84 kW vs 30.7 kW — eight times more at double the speed.
3
A solar farm rated at 100 kW averages 20 kW. What is its capacity factor, and how much energy does it deliver in 24 h?
Hint: CF = 20%; energy = 20 kW × 24 h = 480 kWh.
Virginia Research Institute
Virtual Laboratory · Built by E2 Innovations
Welcome — one quick step before you start