Theory: Managing Spent Fuel

Why Spent Fuel Management Matters

Fuel leaving a reactor is intensely radioactive and keeps producing heat for decades. It is first stored under water in the spent fuel pool, which cools it and shields its radiation. After several years, when its heat has fallen, it can be moved into dry casks that are cooled by natural air flow. The 2011 accident at Fukushima Daiichi focused regulators on what happens if pool cooling is lost, and every US plant now has to show how long its operators have before a pool boils. Dry-cask loading is limited by licensed heat loads. Both rely on decay-heat calculations.

Decay Heat of Spent Fuel

For the first few months the Way–Wigner correlation from the reactor-feedback lab gives a good estimate of the decay heat of a whole core. For fuel cooled for years, designers use correlations fitted to detailed depletion codes. Over most of the dry-storage range, the heat of a typical PWR assembly falls as a power of the cooling time.

Decay Heat Pool (days to months): P_d/P₀ = 0.0622 [ t^(−0.2) − (t + T)^(−0.2) ]   (t, T in seconds)
Dry storage (years): Q(t) ≈ 1.05 (t/5 y)^(−0.6) kW per assembly   (45 GWd/tU PWR fuel)
About 5 MW from a full core after a month; about 0.7 kW per assembly after ten years

Loss of Pool Cooling

If the pool cooling pumps stop, the decay heat goes into the water. Because a pool holds well over a million kilograms of water, the temperature rises slowly, giving operators hours or days to restore cooling or add make-up water. Once the pool boils, water is lost at a rate set by the latent heat, and make-up must replace it to keep the fuel covered.

Pool Heat-Up and Boil-Off Heat-up rate: dT/dt = P_d / (m c_p)   (c_p = 4.18 kJ/kg·°C)
Time to boil: t_boil = (100 − T₀) / (dT/dt)
Boil-off: ṁ = P_d / h_fg   (h_fg = 2257 kJ/kg)
Fresh full-core offloads give the shortest time to boil

Dry Cask Storage

A dry storage system is a welded stainless-steel canister holding 24 to 37 assemblies in a basket, inside a thick concrete or steel overpack. Air enters vents at the bottom, rises past the hot canister, and leaves at the top. The cask's licence sets a maximum total heat load, so that fuel cladding stays below about 400 °C. The radiation shielding must handle the gamma rays of Cs-137 and other fission products, which also decay over the storage period.

Cask Loading Total heat = n × Q(t) ≤ licensed limit     n_max = floor(limit / Q), at most the number of slots
Cs-137: A(t) = A₀ e^(−λt), T½ = 30.08 y
Longer cooling allows full loading under a lower limit

Data Used in This Lab

QuantityValueQuantityValue
Reactor power; operating time3411 MWt; 1.5 yAssemblies in a full core193
Pool water mass (typical)1.0 to 2.0 × 10⁶ kgc_p of water; h_fg at 100 °C4.18 kJ/kg·°C; 2257 kJ/kg
Canister capacity32 PWR assembliesLicensed heat limits24, 34, or 40 kW
Cs-137 per assembly at dischargeabout 2.5 × 10¹⁵ BqCs-137 half-life30.08 y

The assembly decay-heat correlation and Cs-137 inventory are representative fits for 45 GWd/tU PWR fuel, for training only; licensing calculations use depletion codes and NRC Regulatory Guide 3.54 methods. Heat losses from the pool surface and walls are neglected, which makes the time to boil conservative.

Plant engineering

Engineers update the pool time-to-boil after every offload and post it for the operators.

Dry storage campaigns

Fuel is selected for each canister so that total heat and dose rates meet the certificate of compliance.

Repositories

Long-term disposal designs depend on decay heat over centuries, set by Cs-137, Sr-90, and actinides.

Planning with Decay-Heat and Heat-Up Graphs

Decay heat per assembly roughly follows a power law in cooling time, and it rises with burnup because more fission products and actinides have built up. Dry-storage loading plans read the shortest cooling time for each burnup off such a curve. Because the curve is a power law, decay heat has no single half-life: it takes longer to halve the longer the fuel has already cooled. After a loss of pool cooling, the water first heats at a constant level, then boils away at a rate set by the decay heat divided by the latent heat of vaporization, so the depth of water over the fuel falls steadily until make-up water is added.

Apparatus

The systems used to store spent fuel. In the simulation these are modelled for you, and the readings correspond to what each would show.

Spent fuel pool
A stainless-lined concrete pool about 12 m deep; 7 m of water over the fuel shields its radiation.
Pool cooling system
Pumps and heat exchangers normally hold the pool near 30 to 45 °C.
40.0
Level and temperature instruments
Post-Fukushima wide-range instruments monitor pool level and temperature from the control room.
Dry storage canister
A welded stainless-steel canister with a basket holding up to 32 assemblies in helium.
Concrete overpack
A thick concrete shell shields the canister; air flows in at the bottom vents and out at the top.
Loading plan
Lists each assembly's burnup, cooling time, and heat so the canister stays within its limits.

Instructions: Running the Virtual Experiment

You are the spent-fuel engineer. The simulation has two immersive 3D work areas and two graph work areas. The parts build from undergraduate work in Parts A and B to graduate-level analysis in the last step of Parts C and D; the level of each part is shown beside its title. In each one you set the conditions, work out the answer yourself, enter it, and press Check. Record every reading and calculation in your lab report tables (modelled in the Example Report), with a labelled screenshot of each setup. Drag in any 3D view to orbit, and scroll to zoom.

Part A: Loss of Pool Cooling (3D Spent Fuel Pool)Undergraduate
1
Open Simulation → 3D Spent Fuel Pool. Choose 30 days, a full core, m = 1.50 × 10⁶ kg, and T₀ = 40 °C. Choose Predict: decay heat fraction and check it. Then check the decay heat in MW.
2
Check the heat-up rate, the time to boil, and the boil-off rate. Press Play loss of cooling and watch the thermometer reach 100 °C at your predicted time. Press Record this run.
3
Repeat for 3, 7, and 100 days, and for one batch at 3 days. Record all cases in Table A and plot time to boil against days since shutdown.
Part B: Dry Cask Loading (3D Dry Cask Pad)Undergraduate
1
Open 3D Dry Cask Pad. Set t = 10 years, 32 assemblies, and the 24 kW limit. Check the heat per assembly and the total heat load, and decide whether the load is within the limit.
2
Check the largest number of assemblies within the limit and the Cs-137 activity per assembly. Press Record this run.
3
Repeat for 5, 15, 20, and 40 years. Find the shortest cooling time that lets a full 32-assembly load meet the 24 kW limit. Record all runs in Table B.
Part C: When Can the Fuel Go into a Cask? (Graph: Cask Heat Curve)Upper undergraduateGraduate step
1
Open Graph: Cask Heat Curve. Choose 45 GWd/tU, a cooling time of 10 y and a 24 kW limit. Check the heat per assembly and compare the dot with the full-cask allowance line. Then check the shortest cooling time for a full 32-assembly cask. Press Record this run.
2
Repeat at 10 y for 35 and 55 GWd/tU, then for 45 GWd/tU at 5 y with a 28 kW limit, and for 55 GWd/tU at 15 y with a 20 kW limit. Record every run in Table C.
3
From the graph, state how burnup changes the waiting time before loading. Take a labelled screenshot of the curves with your fuel marked.
4
GraduateDecay heat follows a power law, not a single exponential. For each run, check the years after loading until the cask heat load has halved, record it in Table C, and explain why fuel loaded later takes longer to halve.
Part D: Time Available after a Loss of Pool Cooling (Graph: Pool Heat-Up)Upper undergraduateGraduate step
1
Open Graph: Pool Heat-Up. Choose 30 days, 193 assemblies, the temperature view and 12 h. Check the water temperature and the time to boil. Press Record this run.
2
Repeat for 3 and 7 days at 12 h, 100 days at 24 h, and one batch (64 assemblies) at 3 days and 24 h. Record every run in Table D.
3
Switch to the water-depth view and describe the two stages of the event: heat-up with a constant level, then boiling with a falling level.
4
GraduateFor each run, check the time from loss of cooling until only 3.0 m of water is above the fuel. Record it in Table D and explain what it means for connecting emergency make-up water.

Simulation: Spent Fuel Pool, Dry Cask Loading, and Planning Graphs

Spent Fuel Management Virtual LabSet up the equipment, work out your answer, then Check

The reactor (3411 MWt, 18 months of operation) has shut down and fuel has been moved to the pool. Estimate the decay heat of the offloaded fuel with the Way–Wigner equation, then assume all pool cooling is lost. Part A uses this work area.

About this work area: The spent fuel pool holds racks of used fuel under water. You choose the time since shutdown, the number of assemblies offloaded, the pool water mass, and the starting temperature, and you can play a loss of cooling. The Readings panel gives the reactor power, the operating time, and the properties of water, and the temperature is announced as the pool heats.

Setup

Readings

Reactor power P₀—
Operating time T—
Specific heat of water c_p—
Latent heat of vaporization h_fg—
Pool thermometer—

Treat the decay heat as constant over the heat-up (it changes only slowly after several days). Use 1000 kg per m³ for the boiled-off volume.

Work it out, then check

Table A: your loss-of-cooling record
DaysAssembliesP_d (MW)m (10⁶ kg)T₀ (°C)Rate (°C/h)Time to boil (h)Boil-off (m³/h)

Fuel that has cooled in the pool for several years can be moved to dry storage. The canister holds up to 32 assemblies and is licensed for a maximum total heat load. Part B uses this work area.

About this work area: The dry cask pad holds a vertical concrete storage cask with a 32-assembly canister. You choose the cooling time of the fuel, how many assemblies to load, and the licensed heat-load limit. The Readings panel gives the decay-heat correlation for the fuel and the caesium-137 inventory at discharge, and every change is announced.

Setup

Readings

Decay heat per assembly (45 GWd/tU PWR fuel)—
Cs-137 per assembly at discharge—
Cs-137 half-life—
Status—

The correlation Q(t) = 1.05 (t/5)^(−0.6) kW fits assembly decay heat from about 3 to 50 years of cooling.

Work it out, then check

Table B: your dry cask record
t (y)Q (kW)AssembliesTotal (kW)Limit (kW)Within limit?Max assembliesCs-137 (Bq)

Decay heat falls slowly with cooling time and rises with burnup. Plants use this curve to decide when each batch of fuel can go into a dry cask. Part C uses this work area.

About this work area: This graph work area plots the decay heat of one fuel assembly against cooling time for three burnups, with the per-assembly allowance for a full cask. You choose the burnup, the cooling time and the cask heat-load limit. The data table below lists the curves and your fuel, and every change is announced.

Setup

Readings

Decay-heat model—
Allowance per assembly (32 cells)—
Cells in the cask—

Q(t, B) = 1.05 (t/5)^(−0.6) × (B/45) kW per assembly. Simplified training model, not for real loading decisions.

Work it out, then check

Table C: your cask heat-curve record
Burnup (GWd/tU)t (y)Q (kW)Limit (kW)Shortest t for 32 (y)Years to halve after loading

If pool cooling is lost, the water heats to boiling and then boils away. The graph shows how much time operators have at each stage. Part D uses this work area.

About this work area: This graph work area follows the spent fuel pool after a loss of cooling, for 1.50 × 10⁶ kg of water starting at 40 °C. You choose the days since shutdown, the number of assemblies, the view (temperature or water depth above the fuel), and a time. The data table below lists the curve, and every change is announced.

Setup

Readings

Decay heat P_d—
Pool water mass; start temperature—
Pool surface area—
Water above the fuel at the start—

Heat-up uses m c_p dT/dt = P_d with c_p = 4.18 kJ/kg·K; boiling uses h_fg = 2257 kJ/kg and 1000 kg/m³.

Work it out, then check

Table D: your pool heat-up record
DaysAssembliesP_d (MW)Time (h)T (°C)Time to boil (h)Time to 3.0 m (h)

This accessible version provides the same set-up, work-out, and check exercises as the 3D and graph work areas, using native controls, data tables, and screen-reader announcements.

Team Questions

Question 1. A 3411 MWt core that ran for 1.5 years has a decay heat fraction of 0.00145 thirty days after shutdown. What is the decay heat of the full core, in MW?
Question 2. That fuel is in a pool holding 1.50 × 10⁶ kg of water (c_p = 4.18 kJ/kg·°C). If cooling is lost, how fast does the pool heat up, in °C per hour?
Question 3. Starting at 40 °C, how many hours until the pool reaches 100 °C?
Question 4. Once boiling, how much water boils away each hour, in m³ (h_fg = 2257 kJ/kg, 1000 kg/m³)?
Question 5. Using Q(t) = 1.05 (t/5)^(−0.6) kW, what is the heat of one assembly after 10 years of cooling, in kW?
Question 6. What is the total heat load of a canister holding 32 such assemblies, in kW?
Question 7: Challenge. What is the shortest cooling time, in years, that lets 32 assemblies fit under a 24 kW limit?

Example Lab Report

Sample report showing the expected format and level of detail. Use it as a guide for your own submission, and include labelled screenshots of each setup.

Spent Fuel: Pool Heat-Up and Dry Cask Storage

Nuclear Chemistry | Section: [Your Section] | Date: [Date]

Lab Members: [Names of all members present]

Purpose

To calculate the decay heat of offloaded fuel and the pool heat-up rate, time to boil, and boil-off rate after a loss of cooling; and to calculate assembly heat, cask heat load, maximum loading, and Cs-137 inventory for dry storage; then to use a decay-heat curve to plan cask loading by burnup, a pool heat-up graph to find the time available after a loss of cooling, and, at graduate level, the halving time of a power-law heat load and the time until the water level over the fuel falls to 3 m.

Theory

Pool decay heat follows the Way–Wigner equation; the pool heats at P_d/(mc_p), boils after (100 − T₀)/(dT/dt), and loses water at P_d/h_fg. In dry storage each assembly gives Q = 1.05(t/5)^(−0.6) kW, and the cask total n × Q must not exceed its licence limit.

dT/dt = P_d/(mc_p)  ·  t_boil = (100 − T₀)/(dT/dt)  ·  ṁ = P_d/h_fg  ·  Q = 1.05(t/5)^(−0.6)

Table A: Loss of Pool Cooling (m = 1.50 × 10⁶ kg, T₀ = 40 °C) Undergraduate

DaysAssembliesP_d/P₀P_d (MW)Rate (°C/h)Time to boil (h)Boil-off (m³/h)
31930.0033311.3546.5199.218.11
3640.003333.7652.16227.86.01
71930.002538.6304.95512.113.76
301930.001454.9412.83721.17.88
1001930.000802.7121.55738.54.33

Sample calculation (30 days, full core): t = 2.592×10⁶ s; P_d/P₀ = 0.0622 × [t^(−0.2) − (t + 4.734×10⁷)^(−0.2)] = 0.00145; P_d = 4.941 MW; rate = 4941/(1.5×10⁶ × 4.18) × 3600 = 2.837 °C/h; t_boil = 60/2.837 = 21.1 h; boil-off = 4941/2257 × 3.6 = 7.88 m³/h.

Table B: Dry Cask Loading (32 assemblies, 24 kW limit) Undergraduate

t (y)Q (kW)Total (kW)Within 24 kW?Max assembliesCs-137 per assembly (Bq)
51.050033.60no222.228 × 10¹⁵
100.692722.17yes321.986 × 10¹⁵
150.543117.38yes321.769 × 10¹⁵
200.457014.63yes321.577 × 10¹⁵
400.30159.65yes329.946 × 10¹⁴

Shortest cooling time for a full load under 24 kW: Q ≤ 0.75 kW, so t ≥ 5 × (0.75/1.05)^(−1/0.6) = 8.76 y.

Table C: Cask Heat Curve Upper undergraduateGraduate step

Burnup (GWd/tU)t (y)Q (kW)Limit (kW)Shortest t for 32 (y)Years to halve after loading
4510.00.6927248.7621.75
3510.00.5388245.7621.75
5510.00.84672412.2421.75
455.01.0500286.7810.87
5515.00.66382016.5932.62

Q = 1.05 (t/5)^(−0.6) × (B/45); shortest t = 5 × [32 × 1.05 × (B/45)/limit]^(1/0.6). Graduate step: heat halves at t₀ × 2^(1/0.6) = 3.17 t₀, so a cask loaded at 10 y needs 21.7 more years, and one loaded at 5 y needs 10.9.

Table D: Pool Heat-Up and Boil-Off (m = 1.50 × 10⁶ kg, T₀ = 40 °C, area 120 m², 7.0 m above the fuel) Upper undergraduateGraduate step

DaysAssembliesP_d (MW)Time (h)T (°C)Time to boil (h)Time to 3.0 m (h)
301934.9411274.021.182.0
319311.35412100.09.235.7
71938.6301299.512.147.0
1001932.7122477.438.5149.5
3643.7652491.927.8107.7

Graduate step: time to 3.0 m = t_boil + 4.0 m × 120 m² ÷ boil-off rate. At 30 days with a full core: 21.1 + 480/7.88 = 82.0 h.

Discussion

Decay heat fell from 11.4 MW three days after shutdown to 2.7 MW after 100 days, so the time available after a loss of pool cooling grew from 9 hours to almost 39 hours. A full-core offload three days after shutdown is the most demanding case, which is why plants schedule offloads, keep backup cooling ready, and install the post-Fukushima make-up connections: 18 m³ of water per hour would have to be added to keep up with boiling. Offloading only one batch tripled the time to boil.

Five-year-old fuel was too hot to fill a 24 kW cask (33.6 kW for 32 assemblies; only 22 allowed). After 8.8 years a full load fits, and after 10 years the cask holds 22.2 kW. Over the same period Cs-137 fell only by about 11%, so the gamma shielding requirement changes much more slowly than the heat load: the cask must still provide heavy shielding after decades.

The graphs turned these results into planning tools. On the cask heat curve, higher burnup moved the whole curve up: at a 24 kW limit, 35 GWd/tU fuel could be loaded after 5.8 years but 55 GWd/tU fuel needed 12.2 years. The pool graph showed two stages after a loss of cooling: the level stays constant while the water heats, then falls once boiling starts. Even three days after shutdown with a full core, the water stayed more than 3 m above the fuel for about 36 hours.

The graduate steps showed two points that simple rules miss. Decay heat has no fixed half-life: because it follows a power law, a cask loaded at 10 years takes about 22 more years to halve its heat, while one loaded at 5 years takes about 11. The boil-off step converted heat into a time for connecting make-up water: from 36 hours for a fresh full-core offload to about 150 hours after 100 days, which is why emergency make-up connections must be ready during refuelling outages.

Conclusion

Decay heat set the time available to respond to a loss of pool cooling and the cooling time needed before dry storage. Heat load, not radiation, limited early cask loading, while Cs-137 determines shielding for decades.

Practice Questions

Show all work and include units.

Question 1
A pool holds 1.2 × 10⁶ kg of water at 35 °C with a full core 7 days after shutdown. Find the time to boil and the make-up water needed per day once boiling.
Hint: use your Table A decay heat for 7 days.
Question 2
The pool has 7.0 m of water above the fuel and a surface area of 120 m². At the 3-day full-core boil-off rate, how long would it take to uncover the fuel if no make-up water were added?
Hint: volume above fuel ÷ boil-off rate.
Question 3
Why does the time to boil grow so much faster than linearly with time after shutdown?
Hint: look at how P_d falls in the Way–Wigner equation.
Question 4
A canister is licensed for 34 kW. What is the shortest cooling time for a full 32-assembly load?
Hint: Q ≤ 34/32 kW.
Question 5
How long must fuel be stored for its Cs-137 activity to fall to 1% of the discharge value?
Hint: e^(−λt) = 0.01.
Question 6: Challenge
A loading plan mixes 20 assemblies cooled 8 years with 12 assemblies cooled 25 years. Is the 24 kW limit met? Suggest a better arrangement inside the basket, and explain why hot assemblies are usually placed in the centre or the periphery according to the cask design.
Hint: compute each group's heat; think about heat paths to the canister wall.