Theory: Managing Spent Fuel
Why Spent Fuel Management Matters
Fuel leaving a reactor is intensely radioactive and keeps producing heat for decades. It is first stored under water in the spent fuel pool, which cools it and shields its radiation. After several years, when its heat has fallen, it can be moved into dry casks that are cooled by natural air flow. The 2011 accident at Fukushima Daiichi focused regulators on what happens if pool cooling is lost, and every US plant now has to show how long its operators have before a pool boils. Dry-cask loading is limited by licensed heat loads. Both rely on decay-heat calculations.
Decay Heat of Spent Fuel
For the first few months the Way–Wigner correlation from the reactor-feedback lab gives a good estimate of the decay heat of a whole core. For fuel cooled for years, designers use correlations fitted to detailed depletion codes. Over most of the dry-storage range, the heat of a typical PWR assembly falls as a power of the cooling time.
Dry storage (years): Q(t) ≈ 1.05 (t/5 y)^(−0.6) kW per assembly (45 GWd/tU PWR fuel)
Loss of Pool Cooling
If the pool cooling pumps stop, the decay heat goes into the water. Because a pool holds well over a million kilograms of water, the temperature rises slowly, giving operators hours or days to restore cooling or add make-up water. Once the pool boils, water is lost at a rate set by the latent heat, and make-up must replace it to keep the fuel covered.
Time to boil: t_boil = (100 − T₀) / (dT/dt)
Boil-off: ṁ = P_d / h_fg (h_fg = 2257 kJ/kg)
Dry Cask Storage
A dry storage system is a welded stainless-steel canister holding 24 to 37 assemblies in a basket, inside a thick concrete or steel overpack. Air enters vents at the bottom, rises past the hot canister, and leaves at the top. The cask's licence sets a maximum total heat load, so that fuel cladding stays below about 400 °C. The radiation shielding must handle the gamma rays of Cs-137 and other fission products, which also decay over the storage period.
Cs-137: A(t) = A₀ e^(−λt), T½ = 30.08 y
Data Used in This Lab
| Quantity | Value | Quantity | Value |
|---|---|---|---|
| Reactor power; operating time | 3411 MWt; 1.5 y | Assemblies in a full core | 193 |
| Pool water mass (typical) | 1.0 to 2.0 × 10⁶ kg | c_p of water; h_fg at 100 °C | 4.18 kJ/kg·°C; 2257 kJ/kg |
| Canister capacity | 32 PWR assemblies | Licensed heat limits | 24, 34, or 40 kW |
| Cs-137 per assembly at discharge | about 2.5 × 10¹⁵ Bq | Cs-137 half-life | 30.08 y |
The assembly decay-heat correlation and Cs-137 inventory are representative fits for 45 GWd/tU PWR fuel, for training only; licensing calculations use depletion codes and NRC Regulatory Guide 3.54 methods. Heat losses from the pool surface and walls are neglected, which makes the time to boil conservative.
Plant engineering
Engineers update the pool time-to-boil after every offload and post it for the operators.
Dry storage campaigns
Fuel is selected for each canister so that total heat and dose rates meet the certificate of compliance.
Repositories
Long-term disposal designs depend on decay heat over centuries, set by Cs-137, Sr-90, and actinides.
Planning with Decay-Heat and Heat-Up Graphs
Decay heat per assembly roughly follows a power law in cooling time, and it rises with burnup because more fission products and actinides have built up. Dry-storage loading plans read the shortest cooling time for each burnup off such a curve. Because the curve is a power law, decay heat has no single half-life: it takes longer to halve the longer the fuel has already cooled. After a loss of pool cooling, the water first heats at a constant level, then boils away at a rate set by the decay heat divided by the latent heat of vaporization, so the depth of water over the fuel falls steadily until make-up water is added.
Apparatus
The systems used to store spent fuel. In the simulation these are modelled for you, and the readings correspond to what each would show.
Instructions: Running the Virtual Experiment
You are the spent-fuel engineer. The simulation has two immersive 3D work areas and two graph work areas. The parts build from undergraduate work in Parts A and B to graduate-level analysis in the last step of Parts C and D; the level of each part is shown beside its title. In each one you set the conditions, work out the answer yourself, enter it, and press Check. Record every reading and calculation in your lab report tables (modelled in the Example Report), with a labelled screenshot of each setup. Drag in any 3D view to orbit, and scroll to zoom.
Simulation: Spent Fuel Pool, Dry Cask Loading, and Planning Graphs
The reactor (3411 MWt, 18 months of operation) has shut down and fuel has been moved to the pool. Estimate the decay heat of the offloaded fuel with the Way–Wigner equation, then assume all pool cooling is lost. Part A uses this work area.
Setup
Readings
Treat the decay heat as constant over the heat-up (it changes only slowly after several days). Use 1000 kg per m³ for the boiled-off volume.
Work it out, then check
| Days | Assemblies | P_d (MW) | m (10⁶ kg) | T₀ (°C) | Rate (°C/h) | Time to boil (h) | Boil-off (m³/h) |
|---|
Fuel that has cooled in the pool for several years can be moved to dry storage. The canister holds up to 32 assemblies and is licensed for a maximum total heat load. Part B uses this work area.
Setup
Readings
The correlation Q(t) = 1.05 (t/5)^(−0.6) kW fits assembly decay heat from about 3 to 50 years of cooling.
Work it out, then check
| t (y) | Q (kW) | Assemblies | Total (kW) | Limit (kW) | Within limit? | Max assemblies | Cs-137 (Bq) |
|---|
Decay heat falls slowly with cooling time and rises with burnup. Plants use this curve to decide when each batch of fuel can go into a dry cask. Part C uses this work area.
Setup
Readings
Q(t, B) = 1.05 (t/5)^(−0.6) × (B/45) kW per assembly. Simplified training model, not for real loading decisions.
Work it out, then check
| Burnup (GWd/tU) | t (y) | Q (kW) | Limit (kW) | Shortest t for 32 (y) | Years to halve after loading |
|---|
If pool cooling is lost, the water heats to boiling and then boils away. The graph shows how much time operators have at each stage. Part D uses this work area.
Setup
Readings
Heat-up uses m c_p dT/dt = P_d with c_p = 4.18 kJ/kg·K; boiling uses h_fg = 2257 kJ/kg and 1000 kg/m³.
Work it out, then check
| Days | Assemblies | P_d (MW) | Time (h) | T (°C) | Time to boil (h) | Time to 3.0 m (h) |
|---|
This accessible version provides the same set-up, work-out, and check exercises as the 3D and graph work areas, using native controls, data tables, and screen-reader announcements.
Team Questions
Example Lab Report
Sample report showing the expected format and level of detail. Use it as a guide for your own submission, and include labelled screenshots of each setup.
Spent Fuel: Pool Heat-Up and Dry Cask Storage
Nuclear Chemistry | Section: [Your Section] | Date: [Date]
Lab Members: [Names of all members present]
Purpose
To calculate the decay heat of offloaded fuel and the pool heat-up rate, time to boil, and boil-off rate after a loss of cooling; and to calculate assembly heat, cask heat load, maximum loading, and Cs-137 inventory for dry storage; then to use a decay-heat curve to plan cask loading by burnup, a pool heat-up graph to find the time available after a loss of cooling, and, at graduate level, the halving time of a power-law heat load and the time until the water level over the fuel falls to 3 m.
Theory
Pool decay heat follows the Way–Wigner equation; the pool heats at P_d/(mc_p), boils after (100 − T₀)/(dT/dt), and loses water at P_d/h_fg. In dry storage each assembly gives Q = 1.05(t/5)^(−0.6) kW, and the cask total n × Q must not exceed its licence limit.
Table A: Loss of Pool Cooling (m = 1.50 × 10⁶ kg, T₀ = 40 °C) Undergraduate
| Days | Assemblies | P_d/P₀ | P_d (MW) | Rate (°C/h) | Time to boil (h) | Boil-off (m³/h) |
|---|---|---|---|---|---|---|
| 3 | 193 | 0.00333 | 11.354 | 6.519 | 9.2 | 18.11 |
| 3 | 64 | 0.00333 | 3.765 | 2.162 | 27.8 | 6.01 |
| 7 | 193 | 0.00253 | 8.630 | 4.955 | 12.1 | 13.76 |
| 30 | 193 | 0.00145 | 4.941 | 2.837 | 21.1 | 7.88 |
| 100 | 193 | 0.00080 | 2.712 | 1.557 | 38.5 | 4.33 |
Sample calculation (30 days, full core): t = 2.592×10⁶ s; P_d/P₀ = 0.0622 × [t^(−0.2) − (t + 4.734×10⁷)^(−0.2)] = 0.00145; P_d = 4.941 MW; rate = 4941/(1.5×10⁶ × 4.18) × 3600 = 2.837 °C/h; t_boil = 60/2.837 = 21.1 h; boil-off = 4941/2257 × 3.6 = 7.88 m³/h.
Table B: Dry Cask Loading (32 assemblies, 24 kW limit) Undergraduate
| t (y) | Q (kW) | Total (kW) | Within 24 kW? | Max assemblies | Cs-137 per assembly (Bq) |
|---|---|---|---|---|---|
| 5 | 1.0500 | 33.60 | no | 22 | 2.228 × 10¹⁵ |
| 10 | 0.6927 | 22.17 | yes | 32 | 1.986 × 10¹⁵ |
| 15 | 0.5431 | 17.38 | yes | 32 | 1.769 × 10¹⁵ |
| 20 | 0.4570 | 14.63 | yes | 32 | 1.577 × 10¹⁵ |
| 40 | 0.3015 | 9.65 | yes | 32 | 9.946 × 10¹⁴ |
Shortest cooling time for a full load under 24 kW: Q ≤ 0.75 kW, so t ≥ 5 × (0.75/1.05)^(−1/0.6) = 8.76 y.
Table C: Cask Heat Curve Upper undergraduateGraduate step
| Burnup (GWd/tU) | t (y) | Q (kW) | Limit (kW) | Shortest t for 32 (y) | Years to halve after loading |
|---|---|---|---|---|---|
| 45 | 10.0 | 0.6927 | 24 | 8.76 | 21.75 |
| 35 | 10.0 | 0.5388 | 24 | 5.76 | 21.75 |
| 55 | 10.0 | 0.8467 | 24 | 12.24 | 21.75 |
| 45 | 5.0 | 1.0500 | 28 | 6.78 | 10.87 |
| 55 | 15.0 | 0.6638 | 20 | 16.59 | 32.62 |
Q = 1.05 (t/5)^(−0.6) × (B/45); shortest t = 5 × [32 × 1.05 × (B/45)/limit]^(1/0.6). Graduate step: heat halves at t₀ × 2^(1/0.6) = 3.17 t₀, so a cask loaded at 10 y needs 21.7 more years, and one loaded at 5 y needs 10.9.
Table D: Pool Heat-Up and Boil-Off (m = 1.50 × 10⁶ kg, T₀ = 40 °C, area 120 m², 7.0 m above the fuel) Upper undergraduateGraduate step
| Days | Assemblies | P_d (MW) | Time (h) | T (°C) | Time to boil (h) | Time to 3.0 m (h) |
|---|---|---|---|---|---|---|
| 30 | 193 | 4.941 | 12 | 74.0 | 21.1 | 82.0 |
| 3 | 193 | 11.354 | 12 | 100.0 | 9.2 | 35.7 |
| 7 | 193 | 8.630 | 12 | 99.5 | 12.1 | 47.0 |
| 100 | 193 | 2.712 | 24 | 77.4 | 38.5 | 149.5 |
| 3 | 64 | 3.765 | 24 | 91.9 | 27.8 | 107.7 |
Graduate step: time to 3.0 m = t_boil + 4.0 m × 120 m² ÷ boil-off rate. At 30 days with a full core: 21.1 + 480/7.88 = 82.0 h.
Discussion
Decay heat fell from 11.4 MW three days after shutdown to 2.7 MW after 100 days, so the time available after a loss of pool cooling grew from 9 hours to almost 39 hours. A full-core offload three days after shutdown is the most demanding case, which is why plants schedule offloads, keep backup cooling ready, and install the post-Fukushima make-up connections: 18 m³ of water per hour would have to be added to keep up with boiling. Offloading only one batch tripled the time to boil.
Five-year-old fuel was too hot to fill a 24 kW cask (33.6 kW for 32 assemblies; only 22 allowed). After 8.8 years a full load fits, and after 10 years the cask holds 22.2 kW. Over the same period Cs-137 fell only by about 11%, so the gamma shielding requirement changes much more slowly than the heat load: the cask must still provide heavy shielding after decades.
The graphs turned these results into planning tools. On the cask heat curve, higher burnup moved the whole curve up: at a 24 kW limit, 35 GWd/tU fuel could be loaded after 5.8 years but 55 GWd/tU fuel needed 12.2 years. The pool graph showed two stages after a loss of cooling: the level stays constant while the water heats, then falls once boiling starts. Even three days after shutdown with a full core, the water stayed more than 3 m above the fuel for about 36 hours.
The graduate steps showed two points that simple rules miss. Decay heat has no fixed half-life: because it follows a power law, a cask loaded at 10 years takes about 22 more years to halve its heat, while one loaded at 5 years takes about 11. The boil-off step converted heat into a time for connecting make-up water: from 36 hours for a fresh full-core offload to about 150 hours after 100 days, which is why emergency make-up connections must be ready during refuelling outages.
Conclusion
Decay heat set the time available to respond to a loss of pool cooling and the cooling time needed before dry storage. Heat load, not radiation, limited early cask loading, while Cs-137 determines shielding for decades.
Practice Questions
Show all work and include units.