Theory: The Rankine Steam Cycle

Why the Steam Cycle Matters

A nuclear plant is a heat engine. The reactor supplies heat, but only about a third of it becomes electricity; the rest must be rejected to a river, lake, sea, or cooling tower. The secondary-side performance engineer tracks turbine efficiency, condenser vacuum, and heat rate every day, because each 0.1% of efficiency is worth over a megawatt of output for the life of the plant. The same thermodynamics sets the size of the cooling system and the plant's environmental permits.

The Rankine Cycle

Water and steam pass through four steps. (1→2) Saturated steam from the steam generator expands through the turbine to the condenser pressure, producing work. (2→3) The wet exhaust steam condenses to saturated liquid in the condenser. (3→4) The feed pump raises the liquid back to steam-generator pressure. (4→1) The steam generator boils it again. An ideal turbine expands steam isentropically (at constant entropy); a real turbine reaches a higher exhaust enthalpy, described by its isentropic efficiency.

Turbine Expansion Isentropic exhaust: x₂s = (s₁ − s_f)/s_fg     h₂s = h_f + x₂s h_fg
Real exhaust: h₂ = h₁ − η_t (h₁ − h₂s)
The exhaust is wet steam, about 70% vapour
Cycle Efficiency Pump work: w_p = v_f (P_high − P_low)     h₄ = h_f + w_p
Net work: w_net = (h₁ − h₂) − w_p     Heat added: q_in = h₁ − h₄
η = w_net / q_in
A colder condenser (lower pressure) raises the efficiency

Electrical Output, Heat Rejection, and Heat Rate

The plant's electrical output is the reactor power times the cycle efficiency and the generator efficiency. Almost all the remaining heat leaves through the condenser, where cooling water carries it away. The heat rate (heat input per kilowatt-hour of electricity) is the industry's standard measure of plant performance; lower is better.

Plant Balance P_e = P_th × η × η_gen     Q_rej ≈ P_th (1 − η)
Cooling water: ṁ = Q_rej / (c_p ΔT)     Heat rate = 3600 / (η η_gen) kJ/kWh
A 3411 MWt plant rejects about 2300 MW, needing over 50 m³/s of cooling water

Reading the Cycle on a T–s Diagram

On a temperature–entropy diagram, heat added in a reversible process is the area under its path, so the cycle's net work is the area enclosed. An ideal turbine expands straight down at constant entropy (1 → 2s); a real turbine generates entropy, so state 2 lies to the right and the lost work is about T_cond × (s₂ − s₁). The mean temperature of heat addition, T̄ = (h₁ − h₄)/(s₁ − s₄), sets the best efficiency possible, 1 − T_cond/T̄. Raising the condenser temperature in summer raises T_cond and lowers both the ideal limit and the real output.

Graph Relations x₂ = (h₂ − h_f)/h_fg  ·  s₂ = s_f + x₂ s_fg
T̄ = (h₁ − h₄)/(s₁ − s₄)  ·  η_ideal ≤ 1 − T_cond/T̄
Between 5 and 10 kPa, each kilopascal of lost condenser vacuum costs a large plant about 10 MWe

Steam-Table Data Used in This Lab

StateT_sat (°C)h_fh_fgs_fs_fgv_f (m³/kg)
Throttle: 6.9 MPa saturated steam285h₁ = h_g = 2773 kJ/kgs₁ = s_g = 5.815 kJ/kg·K—
Condenser 5 kPa32.9137.82423.00.47637.91870.001005
Condenser 7 kPa39.0163.42409.10.55917.71670.001007
Condenser 10 kPa45.8191.82392.80.64937.50090.001010

Properties from standard steam tables, rounded (enthalpy in kJ/kg, entropy in kJ/kg·K), as used in the DOE Fundamentals Handbook (Thermodynamics, Heat Transfer, and Fluid Flow). Real plants reach 33–35% with moisture separators, reheaters, and feedwater heaters, which this simple cycle leaves out.

Performance engineering

Engineers trend turbine efficiency, condenser vacuum, and heat rate to find losses worth fixing.

Environmental permits

Cooling-water flow and temperature rise are limited by discharge permits that protect rivers and lakes.

Uprates

Power uprates and turbine retrofits are justified by the extra megawatts calculated from these balances.

Apparatus

The secondary-plant equipment of a nuclear unit. In the simulation these are modelled for you, and the readings correspond to what each would show.

HP and LP turbines
Steam expands through the high- and low-pressure turbines on one shaft.
G
Generator
Converts shaft work to electricity at about 98.5% efficiency.
Condenser
Thousands of tubes carry cooling water; the shell is held at a vacuum of a few kPa.
Feed pumps
Raise condensate back to steam-generator pressure.
Cooling tower
Rejects the condenser heat to the air by evaporation.
Steam Tables
Steam tables
Give h, s, and v for water and steam at every pressure and temperature.

Instructions: Running the Virtual Experiment

You are the performance engineer for the secondary plant. The simulation has two immersive 3D work areas and two graph work areas. The parts build from undergraduate work in Parts A and B to graduate-level analysis in the last step of Parts C and D; the level of each part is shown beside its title. In each one you set the conditions, work out the answer yourself, enter it, and press Check. Record every reading and calculation in your lab report tables (modelled in the Example Report), with a labelled screenshot of each setup. Drag in any 3D view to orbit, and scroll to zoom. Each graph also lists its plotted values in a table you can open below it. Use the steam-table data in the Theory section.

Part A: Rankine Cycle Efficiency (3D Turbine Expansion)Undergraduate
1
Open Simulation → 3D Turbine Expansion. Choose 7 kPa and η_t = 0.85. Check the isentropic quality and the isentropic exhaust enthalpy.
2
Check the actual exhaust enthalpy, the net work, and the thermal efficiency. Compare them with the T–s diagram. Press Record this run.
3
Repeat with η_t = 0.90, and then at 5 kPa and 10 kPa. Record all runs in Table A and explain how condenser vacuum and turbine condition affect efficiency.
Part B: Output, Heat Rejection, and Heat Rate (3D Condenser and Cooling)Undergraduate
1
Open 3D Condenser and Cooling. Set 100% power, 31.37% efficiency, and ΔT = 10 °C. Check the electrical output, the heat rejected, the cooling-water flow, and the heat rate. Press Record this run.
2
Repeat with 33.23% and 34.04% efficiency, then with a 6 °C temperature rise, and at 75% power. Record all runs in Table B.
3
Calculate how many extra MWe the plant gains by going from 31.37% to 33.23%, and explain why environmental permits that limit ΔT increase the cooling-water flow needed.
Part C: The Cycle on a T–s Diagram (Graph: T–s Diagram)Upper undergraduateGraduate step
1
Open Graph: T–s Diagram. Set 7 kPa and η_t = 0.85. Check the actual turbine-exit quality x₂, the entropy generated in the turbine, and the mean temperature of heat addition T̄. Press Record this run.
2
At 7 kPa, repeat with η_t = 1.00 and 0.75. Then set η_t = 0.85 and check 5, 10, and 20 kPa. Watch state 2 move on the diagram. Record all runs in Table C.
3
Take a labelled screenshot of the diagram at 7 kPa and η_t = 0.85. In your report, explain why a less efficient turbine gives drier exhaust steam, and compare 1 − T_cond/T̄ with the cycle efficiency from Part A.
4
GraduateCheck the second-law efficiency η_II = η/(1 − T_cond/T̄) at 7 kPa for η_t = 0.85, 1.00, and 0.75. Add an η_II column to Table C and explain why η_II tracks the turbine efficiency so closely.
Part D: Output against Condenser Pressure (Graph: Condenser Pressure)Upper undergraduateGraduate step
1
Open Graph: Condenser Pressure. Keep η_t = 0.85 and choose 10 kPa (summer). Check the net electrical output, the output lost compared with 5 kPa, and the heat-rate increase. Press Record this run.
2
Repeat for 4, 7, 15, and 20 kPa, and record each in Table D. Read from the graph roughly how many MWe each extra kilopascal costs.
3
Take a labelled screenshot of the graph. Explain why plants watch condenser vacuum closely in summer, and what a loss of vacuum from air in-leakage would do to output.
4
GraduateDesign case: the cooling water enters at 25 °C, warms by 10 °C, and the condenser terminal temperature difference is 5 °C. Find the condenser pressure by interpolating ln P in the steam tables, then check the output with 25 °C summer cooling water at η_t = 0.85 and 0.90. Record both under Table D.

Simulation: Turbine Expansion, Condenser Heat Balance, and Performance Graphs

Steam Cycle Virtual LabSet up the equipment, work out your answer, then Check

Saturated steam at 6.9 MPa enters the turbine (state 1) and expands to the condenser pressure (state 2). Condensate leaves the condenser as saturated liquid (state 3), and the feed pump raises it back to 6.9 MPa (state 4). Part A uses this work area.

About this work area: The turbine area follows the Rankine cycle: steam generator, turbine, condenser, and feed pump. You choose the condenser pressure and the turbine efficiency. The Readings panel gives the steam-table data for the throttle steam and for the condenser pressure chosen, and every change is announced.

Setup

Readings

Throttle steam h₁; s₁—
Condenser T_sat—
h_f; h_fg—
s_f; s_fg—
Specific volume of condensate v_f—

Pump work w_p = v_f (P_high − P_low) in kJ/kg (with pressures in kPa). Thermal efficiency = net work / heat added.

Work it out, then check

Table A: your Rankine cycle record
P_cond (kPa)η_tx₂sh₂s (kJ/kg)h₂ (kJ/kg)w_p (kJ/kg)w_net (kJ/kg)η (%)

Only about a third of the reactor's heat becomes electricity. The rest is rejected in the condenser and carried away by circulating cooling water. Part B uses this work area.

About this work area: The condenser area shows the condenser, the circulating water pumps, and a cooling tower. You choose the reactor power, the cycle efficiency, and the cooling-water temperature rise. The Readings panel gives the generator efficiency and the properties of the cooling water, and every change is announced.

Setup

Readings

Rated thermal power—
Generator efficiency—
Cooling-water specific heat; density—

Electrical output = P_th × η × η_gen. Heat rejected in the condenser ≈ P_th (1 − η). Heat rate = 3600 / (η × η_gen) kJ per kWh.

Work it out, then check

Table B: your condenser record
P_th (MW)η (%)ΔT (°C)MWeQ_rej (MW)Cooling water (m³/s)Heat rate (kJ/kWh)

A temperature–entropy diagram shows the whole cycle at once. The area under the heating line is the heat added; a real turbine moves state 2 to the right of the ideal state 2s. Part C uses this work area.

About this work area: This graph work area draws the Rankine cycle on a temperature–entropy diagram with the saturation dome. You choose the condenser pressure and the turbine isentropic efficiency. The data table below lists the coordinates of each state point, and every change is announced.

Setup

Readings

Throttle steam h₁; s₁—
Condenser T_sat—
h_f; h_fg—
s_f; s_fg—
Ideal and actual exhaust enthalpy—

x₂ = (h₂ − h_f)/h_fg; s₂ = s_f + x₂ s_fg. Mean temperature of heat addition T̄ = (h₁ − h₄)/(s₁ − s₄), with s₄ ≈ s_f.

Work it out, then check

Table C: your T–s diagram record
P_cond (kPa)η_tT_sat (°C)x₂sx₂s₂ − s₁ (kJ/kg·K)T̄ (K)

Condenser pressure is set by the cooling-water temperature. A few kilopascals of lost vacuum cost many megawatts. Part D uses this work area.

About this work area: This graph work area plots the net electrical output of a 3411 MWt plant against condenser pressure for the turbine efficiency you choose. You choose the condenser pressure and the turbine efficiency. The data table below lists the output and heat rate at every pressure, and every change is announced.

Setup

Readings

Reactor thermal power—
Generator efficiency—
Cycle efficiency at this pressure—
Cycle efficiency at 5 kPa (winter)—
Summer design case (advanced)—

MWe = 3411 × η × 0.985. Heat rate = 3600/(η × 0.985) kJ/kWh. Compare each pressure with the 5 kPa winter case.

Work it out, then check

Table D: your condenser-pressure record
P_cond (kPa)η_tη (%)MWeMW lost vs 5 kPaHeat rate (kJ/kWh)Heat-rate rise (kJ/kWh)

This accessible version provides the same set-up, work-out, and check exercises as the 3D and graph work areas, using native controls, data tables, and screen-reader announcements.

Team Questions

Question 1. Saturated steam with s₁ = 5.815 kJ/kg·K expands isentropically to 7 kPa (s_f = 0.5591, s_fg = 7.7167). What is the exhaust quality?
Question 2. With h_f = 163.4 and h_fg = 2409.1 kJ/kg at 7 kPa, what is the isentropic exhaust enthalpy, in kJ/kg?
Question 3. h₁ = 2773 kJ/kg and the turbine efficiency is 0.85. What is the actual exhaust enthalpy, in kJ/kg?
Question 4. The pump work is 6.94 kJ/kg and h₄ = 170.3 kJ/kg. What is the cycle thermal efficiency, in %?
Question 5. A 3411 MWt plant runs at 31.37% cycle efficiency with a 98.5% efficient generator. What is its electrical output, in MWe?
Question 6. How much cooling water does its condenser need for a 10 °C rise, in m³/s (c_p = 4.18 kJ/kg·°C)?
Question 7: Challenge. What is the plant's heat rate, in kJ/kWh?

Example Lab Report

Sample report showing the expected format and level of detail. Use it as a guide for your own submission, and include labelled screenshots of each setup.

The Steam Cycle: Turbine, Condenser, and Plant Efficiency

Nuclear Engineering Technology | Section: [Your Section] | Date: [Date]

Lab Members: [Names of all members present]

Purpose

To calculate the state points, net work, and thermal efficiency of a nuclear plant's Rankine cycle for different condenser pressures and turbine efficiencies, and the electrical output, heat rejection, cooling-water flow, and heat rate of the plant; and to use a temperature–entropy diagram and a graph of output against condenser pressure to locate where the cycle loses work.

Theory

The turbine expands steam from h₁ to h₂ = h₁ − η_t(h₁ − h₂s), where h₂s follows from constant entropy. Net work is (h₁ − h₂) − w_p and efficiency is w_net/(h₁ − h₄). Output is P_thηη_gen, and the condenser rejects about P_th(1 − η).

x₂s = (s₁ − s_f)/s_fg  ·  h₂ = h₁ − η_t(h₁ − h₂s)  ·  η = w_net/q_in  ·  ṁ_cw = Q_rej/(c_pΔT)

Table A: Rankine Cycle Undergraduate

P_cond (kPa)η_tx₂sh₂sh₂w_pw_netη (%)
70.850.68111804.31949.66.94816.531.37
70.900.68111804.31901.16.94864.933.23
50.850.67421771.41921.66.93844.532.13
100.850.68871839.71979.76.96786.430.55

Units: enthalpies and work in kJ/kg. Sample calculation (7 kPa, 0.85): x₂s = (5.815 − 0.5591)/7.7167 = 0.6811; h₂s = 163.4 + 0.6811 × 2409.1 = 1804.3; h₂ = 2773 − 0.85 × 968.7 = 1949.6; w_p = 0.001007 × 6893 = 6.94; η = 816.5/2602.7 = 31.37%.

Table B: Plant Output and Cooling Undergraduate

P_th (MW)η (%)ΔT (°C)MWeQ_rej (MW)Cooling water (m³/s)Heat rate (kJ/kWh)
341131.37101054234156.011 651
341133.23101116227854.510 999
341134.04101144225053.810 737
341131.3761054234193.311 651
255831.3710790175642.011 651

Table C: The Cycle on a T–s Diagram Upper undergraduateGraduate step

P_cond (kPa)η_tT_sat (°C)x₂sx₂s₂ − s₁ (kJ/kg·K)T̄ (K)
70.8539.00.68110.74140.4655495.2
71.0039.00.68110.68110.0000495.2
70.7539.00.68110.78160.7758495.2
50.8532.90.67420.73620.4910492.3
100.8545.80.68870.74720.4389498.3
200.8560.060.70430.75910.3877504.6

Sample calculation (7 kPa, 0.85): x₂ = (1949.6 − 163.4)/2409.1 = 0.7414; s₂ = 0.5591 + 0.7414 × 7.7167 = 6.2805, so s₂ − s₁ = 0.4655; T̄ = (2773 − 170.3)/(5.815 − 0.5591) = 495.2 K. Include a screenshot of the diagram.

Graduate step: at 7 kPa, 1 − T_cond/T̄ = 1 − 312.15/495.2 = 36.96%. η_II = 31.37/36.96 = 84.9% at η_t = 0.85, 100.0% at η_t = 1.00, and 74.8% at η_t = 0.75 (84.9% at 5, 10, and 20 kPa with η_t = 0.85).

Table D: Output against Condenser Pressure (3411 MWt, η_t = 0.85) Upper undergraduateGraduate step

P_cond (kPa)η_tη (%)MWeMW lost vs 5 kPaHeat rate (kJ/kWh)Heat-rate rise (kJ/kWh)
40.8532.601095−1611211−164
50.8532.1310800113750
70.8531.3710542511650275
100.8530.5510265311964589
150.8529.579938612360985
200.8528.83969111126761301

MWe = 3411 × η × 0.985; heat rate = 3600/(η × 0.985). Negative values at 4 kPa are gains over the winter case. Include a screenshot of the graph.

Graduate step: with 25 °C inlet water, T_sat = 25 + 10 + 5 = 40 °C, so ln P interpolation gives P_cond = 7.38 kPa. The output is 1050 MWe at η_t = 0.85 (30 MWe below the 5 kPa winter case) and 1112 MWe at η_t = 0.90.

Discussion

The turbine exhaust was only 68% vapour, which is why real plants add moisture separators to protect the low-pressure blades. Improving the turbine from 0.85 to 0.90 raised the efficiency by 1.9 points and the output by 62 MWe. Lowering the condenser pressure from 10 to 5 kPa, which needs colder cooling water, raised the efficiency by 1.6 points, which is why plants make more power in winter. The pump work was under 1% of the turbine work.

At 31.4% efficiency the plant rejected 2341 MW, more than twice its electrical output, and needed 56 m³/s of cooling water for a 10 °C rise. A permit that limits the rise to 6 °C raises the flow to 93 m³/s. The heat rate of 11 650 kJ/kWh fell to 10 740 kJ/kWh at 34% efficiency. Heat rate does not depend on power level in this simple model, though real plants are least efficient at low load.

The graphs showed where the losses come from. On the T–s diagram, a less efficient turbine moved state 2 to the right: the exhaust got drier (x₂ = 0.7414 against x₂s = 0.6811 at η_t = 0.85), but 0.4655 kJ/kg·K of entropy was generated, and T_condΔs ≈ 312 × 0.4655 ≈ 145 kJ/kg of work was lost. The mean temperature of heat addition was only about 495 K because the feedwater is heated from condenser temperature, so even an ideal cycle between 495 K and 312 K could reach only 1 − 312/495 = 37%. The second graph showed output falling steadily with condenser pressure: about 53 MWe is lost between a winter 5 kPa and a summer 10 kPa, roughly 10 MWe per kilopascal in that range, and running at 20 kPa costs 111 MWe. This is why condenser cleanliness and air in-leakage are watched every shift.

The graduate steps tied the two graphs to second-law analysis and design. Once feedwater heating is counted through T̄, the cycle reached about 85% of the best reversible cycle between T̄ and the condenser at η_t = 0.85, and η_II rose to 100% with an ideal turbine, so nearly all of the remaining second-law loss is in the turbine. The summer design case showed how the cooling-water temperature, its rise, and the condenser terminal difference set the vacuum: 25 °C water gave 7.38 kPa and cost 30 MWe against winter, and every degree of extra inlet temperature costs output in the same way.

Conclusion

Steam-table calculations gave a Rankine efficiency of 30.5 to 33.2%, rising with turbine efficiency and condenser vacuum. Two-thirds of the reactor heat is rejected in the condenser, setting the size of the cooling system.

Practice Questions

Show all work and include units. Use the steam-table data in the Theory section.

Question 1
Calculate the Carnot efficiency between 285 °C and 39 °C and compare it with the Rankine efficiency in Table A. Why are they different?
Hint: η_Carnot = 1 − T_C/T_H with temperatures in kelvin.
Question 2
Find the actual exhaust quality x₂ for the 7 kPa, η_t = 0.85 case. How much water is in the exhaust?
Hint: x₂ = (h₂ − h_f)/h_fg.
Question 3
What steam flow does the 3411 MWt plant need at 7 kPa and η_t = 0.85?
Hint: ṁ = P_th / (h₁ − h₄).
Question 4
A heat-rate improvement of 1% saves fuel. Estimate the extra MWe a 1% heat-rate improvement gives at 3411 MWt.
Hint: output is inversely proportional to heat rate at constant thermal power.
Question 5
Explain why nuclear plants (about 285 °C steam) are less efficient than modern coal plants (about 600 °C steam).
Hint: think about the temperature at which heat is added.
Question 6: Challenge
A cooling tower loses about 2.4 MJ of heat per kg of water evaporated. Estimate the water evaporated per day at 3411 MWt and 31.37% efficiency.
Hint: evaporation ≈ Q_rej / 2.4 MJ/kg.