Theory: Fission Product Poisons and Fuel Burnup

Why Poisons and Burnup Matter

Fission does not only release energy and neutrons; it leaves behind fission products, and a few of them absorb thermal neutrons so strongly that they act as built-in control rods. The two that matter most are xenon-135 and samarium-149. Their worth changes with power and with time after a power change, so operators must predict them for every startup, power change, and trip. Over a whole cycle the fuel is also used up: U-235 is fissioned, plutonium is bred, and the burnup of each batch sets the cycle length, the refuelling plan, and the fuel cost.

Xenon-135: Production, Burnout, and Decay

Xe-135 has the largest thermal absorption cross section known, about 2.65 × 10⁶ b. About 95% of it comes from the decay of iodine-135 (half-life 6.57 h), which is itself a fission product; the rest is produced directly. At power, xenon is removed in two ways: it decays (half-life 9.14 h), and it absorbs neutrons and becomes Xe-136, which is called burnout. At high flux, burnout dominates, so the equilibrium xenon worth levels off instead of rising in proportion to power. The flux at which burnout equals decay is φ_X = λ_X/σ_X.

Equilibrium Xenon and Samarium (DOE simplified form) I-135 → Xe-135 (β⁻, 6.57 h)    Xe-135 → Cs-135 (β⁻, 9.14 h)    Xe-135 + n → Xe-136
φ_X = λ_X / σ_X     ρ_Xe,eq = −(γ/ν) × φ / (φ + φ_X)
ρ_Sm,eq = −γ_Pm / ν   (independent of flux)
Xenon worth rises with power but saturates; samarium does not depend on power

Xenon after a Trip: The Xenon Peak and Dead Time

When the reactor trips, burnout stops instantly, but the large inventory of I-135 in the fuel keeps decaying to xenon. Because iodine decays faster than xenon, xenon builds up for several hours and then decays away. The peak can be roughly twice the equilibrium value. If the excess reactivity available in the core (from rods and boron) is smaller than the extra xenon worth, the reactor cannot be restarted until xenon decays: the xenon dead time. Late in a cycle, when boron is low, this can last a day or more. The same physics drives xenon oscillations in large cores and the xenon "pit" that operators must manage after a power reduction.

Post-Trip Xenon Worth (no flux after the trip) ρ_Xe(t) = ρ_X0 e^(−λ_X t) + ρ_I0 [λ_I/(λ_X − λ_I)] [e^(−λ_I t) − e^(−λ_X t)]
ρ_I0 = −(γ_I/ν)(σ_X φ/λ_I)   (the iodine inventory expressed as xenon worth)
Peak about 7 to 11 h after a trip; xenon is essentially gone after 3 days

Samarium-149

Sm-149 (σ ≈ 4.1 × 10⁴ b) is produced from promethium-149 (half-life 53 h) and is stable, so it is removed only by burnout. Its equilibrium worth is the same at every power level. After shutdown, the promethium in the fuel decays to samarium, which builds up and stays; it is removed only when the reactor runs again.

Fuel Burnup and Cycle Length

Burnup is the thermal energy produced per tonne of heavy metal, in megawatt-days per tonne of uranium (MWd/tU) or GWd/tU. About 1.05 g of heavy metal is fissioned for each MWd. A cycle is measured in effective full-power days (EFPD). PWRs refuel one-third or one-quarter of the core at each outage, so each assembly stays for three or four cycles and leaves with a discharge burnup of roughly the number of batches times the cycle burnup. US licensing limits the peak rod burnup to about 62 GWd/tU, which, together with the 5% enrichment limit, sets how long cycles can be.

Burnup Cycle burnup = P × EFPD / M_U   (MWd/tU)
Uranium fissioned ≈ 1.05 g × P × EFPD     Discharge burnup ≈ n_batches × cycle burnup
Higher burnup = longer use of each fuel assembly

Operating Graphs: Restart Windows and Boron Letdown

Shift engineers plot the post-trip xenon worth against the reactivity they can add by withdrawing rods and diluting boron. Where the curve rises above that line the reactor cannot be made critical, and the two crossing points mark the start and end of the xenon dead time. Over a whole cycle, the plant tracks the critical boron letdown curve: the soluble boron needed to hold the core critical at full power. It falls quickly at the start of the cycle as xenon and samarium build in, then falls almost linearly as the fuel depletes. The cycle ends when the boron reaches about 0 ppm; after that the plant can only coast down by letting temperature and power fall. Comparing the measured boron with the predicted curve is one of the main checks that the core is behaving as designed.

Data Used in This Lab

QuantityValueQuantityValue
λ_X (Xe-135, 9.14 h)2.09 × 10⁻⁵ s⁻¹λ_I (I-135, 6.57 h)2.87 × 10⁻⁵ s⁻¹
σ_X (Xe-135, thermal)2.65 × 10⁶ bν2.43
γ_I; γ_X (direct); total γ0.0639; 0.0024; 0.0663γ_Pm (Pm-149)0.0113
Full-power thermal flux3.2 × 10¹³ n/cm²·sRated power3411 MWt
Heavy metal fissioned1.05 g per MWdPeak rod burnup limit (US)62 000 MWd/tU

Data follow the DOE Fundamentals Handbook (Nuclear Physics and Reactor Theory, Module 3: Fission Product Poisons), the KAPL Chart of the Nuclides, and IAEA reactor-physics training material. The worth formulas are the simplified handbook forms; plant calculations include f, spatial effects, and the full depletion chains.

Operations

After a trip, the shift calculates xenon and an estimated critical position to decide whether and when a restart is possible.

Load following

Plants that change power for the grid must manage xenon transients and axial xenon oscillations.

Fuel management

Fuel managers choose cycle length, batch size, and enrichment to meet the utility's outage schedule within burnup limits.

Apparatus

The plant tools used to track poisons and burnup. In the simulation these are modelled for you, and the readings correspond to what each would report.

I-135Xe-135Cs-135
Xenon decay chain
Iodine-135 decays to xenon-135, which decays to caesium-135 or absorbs a neutron and becomes Xe-136.
Process computer
Tracks xenon and samarium from the power history and gives the operators the predicted worth after any change.
ECP
ECP worksheet
Combines xenon, samarium, boron, and temperature worths to predict where the reactor will go critical on restart.
Fuel assembly
A 17 × 17 assembly holds about 0.46 tU; a 193-assembly core holds about 89 tU.
Loading pattern
A low-leakage pattern places fresh and once-burned fuel inside and the most-burned fuel on the periphery.
Refuelling machine
Moves assemblies under water during the outage to discharge one batch and shuffle the rest.

Instructions: Running the Virtual Experiment

You are the reactor engineer responsible for poison predictions and the fuel cycle. The simulation has three immersive 3D work areas and two graph work areas. The parts build from undergraduate work in Parts A to C to graduate-level analysis in the last step of Parts D and E; the level of each part is shown beside its title. In each one you set the conditions, read the instruments, work out the answer yourself, enter it, and press Check. Record every reading and calculation in your lab report tables (modelled in the Example Report), with a labelled screenshot of each setup. Drag in any 3D view to orbit, and scroll to zoom. Use the data table in the Theory section.

Part A: Equilibrium Xenon and Samarium (3D Poison Monitor)Undergraduate
1
Open Simulation → 3D Poison Monitor. Choose Predict: xenon burnout flux φ_X, calculate λ_X/σ_X, and check it.
2
Set the power to 100%. Choose Predict: equilibrium xenon worth, calculate ρ_Xe in pcm, and check it. Then check the samarium worth and the total poison worth. Press Record this run.
3
Repeat at 75%, 50%, and 25% and watch the size of the xenon cloud. Record each in Table A and plot ρ_Xe against power. Explain why it is not a straight line.
Part B: Xenon after a Trip (3D Post-Trip Xenon)Undergraduate
1
Open 3D Post-Trip Xenon. Choose 100% before the trip and press Trip and play 72 h. Watch the xenon worth on the board and the clock in the Readings.
2
Choose Predict: time of the xenon peak, read or calculate it, and check it. Then check the peak xenon worth.
3
Choose Predict: xenon worth at time t. For t = 4, 10, 24, and 48 h, calculate ρ_Xe(t) with the post-trip equation, check it, and press Record this run. Repeat the peak and t = 10 h for a trip from 50%. Record all results in Table B.
4
The core has 3000 pcm of excess reactivity available for a restart from 100%. Use your table to find the xenon dead time, the period during which the reactor cannot be restarted.
Part C: Burnup and Cycle Planning (3D Fuel Cycle)Undergraduate
1
Open 3D Fuel Cycle. Set 500 EFPD, 89 tU, and 3 batches. Choose Predict: cycle burnup, calculate it, and check it. Press Run cycle.
2
Check the mass of uranium fissioned and the discharge burnup. Press Record this run.
3
Repeat for 450 and 300 EFPD with 89 tU and 3 batches, and for 500 EFPD with 72 tU and 4 batches. Record all runs in Table C and identify any plan that breaks the 62 000 MWd/tU limit.
Part D: The Restart Window (Graph: Restart Window)Upper undergraduateGraduate step
1
Open Graph: Restart Window. Choose 100% before the trip and 3000 pcm available. Read where the xenon curve crosses the blue line. Check the time the restart window closes, the time it opens again, and the length of the dead time. Press Record this run.
2
Repeat with 3500 and 4000 pcm available (100%), with 3000 pcm after a trip from 75%, and with 2500 and 2000 pcm after a trip from 50%. Record every run in Table D.
3
From the graph, explain how the dead time changes as more reactivity is available, and why a trip from lower power is easier to recover from. Take a labelled screenshot of one restart-window graph for your report.
4
GraduateXenon predictions carry about a ±10% uncertainty. For each run in Table D, check the Advanced: conservative restart time, when the dashed +10% curve falls back below the available-reactivity line, and record it in the last column of Table D. Explain why a restart plan uses this later time.
Part E: The Critical Boron Letdown Curve (Graph: Boron Letdown)Upper undergraduateGraduate step
1
Open Graph: Boron Letdown. Choose 1400 ppm at the beginning of the cycle. Check the clean-core boron at 0 EFPD, before xenon and samarium build in.
2
Set 200 EFPD and check the critical boron. Then check the end-of-cycle point where the boron reaches 0 ppm. Press Record this run.
3
Repeat for 1400 ppm at 400 EFPD, 1200 ppm at 200 EFPD, and 1600 ppm at 300 EFPD. Record all runs in Table E, and compare each end-of-cycle point with the 500 EFPD cycle you planned in Part C.
4
GraduateAt each point in Table E the measured boron comes back 40 ppm above the design curve. Check the Advanced: re-forecast end of cycle: re-fit the letdown rate to the measurement and predict the new end-of-cycle point. Record it in the last column of Table E and convert the 40 ppm offset to a reactivity anomaly in pcm.

Simulation: Poison Monitor, Post-Trip Xenon, Fuel Cycle, and Operating Graphs

Xenon, Samarium, and Burnup Virtual LabSet up the equipment, work out your answer, then Check

The reactor has run steadily long enough for xenon-135 and samarium-149 to reach equilibrium. Full power corresponds to a core-average thermal flux of 3.2 × 10¹³ n/cm²·s, and the flux is proportional to power. Part A uses this work area.

About this work area: The poison monitor shows the core at steady power with its equilibrium xenon-135 and samarium-149. You set the power level. The Readings panel gives the thermal flux and the xenon, iodine, and promethium data, and every change is announced.

Setup

Readings

Thermal flux φ—
Xe-135 decay constant λ_X—
Xe-135 absorption cross section σ_X—
Total Xe-135 yield γ (I-135 + direct)—
Pm-149 yield γ_Pm—
Neutrons per fission ν—

The simplified equilibrium worths here assume all thermal absorptions that matter are in the fuel (f ≈ 1), as in the DOE handbook estimate.

Work it out, then check

Table A: your equilibrium poison record
Power (%)φ (n/cm²·s)φ/(φ + φ_X)ρ_Xe (pcm)ρ_Sm (pcm)Total (pcm)

The reactor trips. Fission stops, so no new iodine or xenon is produced, but the iodine-135 already in the fuel keeps decaying to xenon-135, while xenon is no longer burned out by the flux. Part B uses this work area.

About this work area: The post-trip area follows xenon after a reactor trip. You choose the power before the trip and a time after the trip, and you can play the trip forward. The Readings panel gives the equilibrium xenon worth, the iodine inventory, the decay constants, and a table of the xenon worth every six hours, and the trip progress is announced.

Setup

Readings

Equilibrium Xe worth at trip ρ_X0—
I-135 inventory as Xe worth ρ_I0—
λ_I (I-135, 6.57 h)—
λ_X (Xe-135, 9.14 h)—
Xe worth every 6 h—
Trip clock—

ρ_I0 is the reactivity the iodine would have if it were all xenon: ρ_I0 = −(γ_I/ν)(σ_Xφ/λ_I), with γ_I = 0.0639.

Work it out, then check

Table B: your post-trip xenon record
Power before tript (h)ρ_Xe(t) (pcm)Peak time (h)Peak ρ_Xe (pcm)

A 3411 MWt core is refuelled in batches: at each outage the most-burned batch is discharged and replaced with fresh fuel. Run a cycle and work out the burnup. Part C uses this work area.

About this work area: The fuel cycle area shows the core loading pattern by batch. You set the cycle length in effective full-power days, the uranium loading, and the number of batches. The Readings panel gives the rated power and the uranium consumption factor, and every run is announced.

Setup

Readings

Rated thermal power—
Uranium fissioned per MWd—
Energy produced this cycle—
Cycles run—

About 1.05 g of uranium (mostly U-235, plus plutonium bred from U-238) is fissioned for every megawatt-day of heat.

Work it out, then check

Table C: your fuel cycle record
EFPDLoading (tU)BatchesEnergy (MWd)Cycle burnup (MWd/tU)Fissioned (kg)Discharge burnup (MWd/tU)

After a trip the operators must decide when the reactor can be restarted. The reactivity they can add by withdrawing rods and diluting boron is limited, so while xenon is more negative than that amount, a restart is impossible. Part D uses this work area.

About this work area: This graph work area follows the xenon worth after a trip and compares it with the reactivity available to overcome xenon at a restart. You choose the power before the trip and the reactivity available. The data table below lists the xenon worth hour by hour and the times when the curve crosses the available-reactivity line, and every change is announced.

Setup

Readings

Xenon worth at the trip—
Peak xenon worth—
Peak time—
Rule—

A restart is impossible while |ρ_Xe(t)| is greater than the reactivity available. Read the crossing times from the graph or the data table; ρ_Xe(t) uses the same post-trip equation as Part B.

Work it out, then check

Table D: your restart-window record
Power before tripAvailable (pcm)Peak |ρ_Xe| (pcm)Dead time starts (h)Dead time ends (h)Dead time (h)Advanced: conservative restart (h)

Through a cycle, soluble boron is diluted to make up for the reactivity the fuel loses as it burns. The critical boron letdown curve is the plant's main check that the core is behaving as designed. Part E uses this work area.

About this work area: This graph work area plots the critical boron letdown curve over a fuel cycle. You choose the beginning-of-cycle boron with equilibrium poisons and a point in the cycle in effective full-power days. The data table below lists the critical boron every 50 days and at your point, and every change is announced.

Setup

Readings

Boron worth α_B—
Reactivity lost to depletion—
Equilibrium Xe + Sm at 100% (Part A)—
Letdown after the poisons settle—

C(D) = C_BOC − (20/8) D once xenon and samarium are at equilibrium (after about 30 EFPD). Simplified training model; real curves are flattened early in the cycle by burnable absorbers.

Work it out, then check

Table E: your boron letdown record
C_BOC (ppm)Clean-core boron (ppm)EFPDCritical boron (ppm)End of cycle (EFPD)Advanced: re-forecast EOC (EFPD)

This accessible version provides the same set-up, work-out, and check exercises as the 3D and graph work areas, using native controls, data tables, and screen-reader announcements.

Team Questions

Question 1. Xe-135 has λ_X = 2.09 × 10⁻⁵ s⁻¹ and σ_X = 2.65 × 10⁶ b. What is the burnout flux φ_X, in units of 10¹² n/cm²·s? (e.g. 7.89)
Question 2. Using γ = 0.0663, ν = 2.43, and φ_X = 7.89 × 10¹², what is the equilibrium xenon worth at φ = 3.2 × 10¹³ n/cm²·s, in pcm?
Question 3. What is the equilibrium xenon worth at half that flux (1.6 × 10¹³ n/cm²·s), in pcm?
Question 4. Using γ_Pm = 0.0113 and ν = 2.43, what is the equilibrium samarium worth in pcm?
Question 5. A 3411 MWt reactor with 89 tU runs a 500 EFPD cycle. What is the cycle burnup, in MWd/tU?
Question 6. Using 1.05 g fissioned per MWd, how many kilograms of heavy metal are fissioned in that cycle?
Question 7: Challenge. A reactor trips from full power with ρ_X0 = −2189 pcm and ρ_I0 = −7770 pcm. Using λ_I = 2.87 × 10⁻⁵ s⁻¹ and λ_X = 2.09 × 10⁻⁵ s⁻¹, what is the xenon worth 10.0 h after the trip, in pcm?

Example Lab Report

Sample report showing the expected format and level of detail. Use it as a guide for your own submission, and include labelled screenshots of each setup.

Fission Product Poisons and Fuel Burnup: Xenon, Samarium, and Cycle Length

Nuclear Engineering Technology | Section: [Your Section] | Date: [Date]

Lab Members: [Names of all members present]

Purpose

To calculate equilibrium xenon and samarium worth at different power levels; to predict the xenon transient after a trip, including the peak and the restart dead time; to calculate cycle burnup, uranium fissioned, and discharge burnup for several fuel-cycle plans; and to read restart windows and a critical boron letdown curve from operating graphs.

Theory

At equilibrium, ρ_Xe = −(γ/ν)φ/(φ + φ_X) with φ_X = λ_X/σ_X, and ρ_Sm = −γ_Pm/ν. After a trip, ρ_Xe(t) = ρ_X0e^(−λ_X t) + ρ_I0[λ_I/(λ_X − λ_I)](e^(−λ_I t) − e^(−λ_X t)). Burnup is P × EFPD / M_U, with about 1.05 g fissioned per MWd.

φ_X = λ_X/σ_X  ·  ρ_Xe = −(γ/ν)φ/(φ + φ_X)  ·  ρ_Sm = −γ_Pm/ν  ·  B = P·EFPD/M_U

Table A: Equilibrium Poisons (φ_X = 7.887 × 10¹² n/cm²·s) Undergraduate

Power (%)φ (n/cm²·s)φ/(φ + φ_X)ρ_Xe (pcm)ρ_Sm (pcm)Total (pcm)
1003.20 × 10¹³0.8023−2189−465−2654
752.40 × 10¹³0.7527−2054−465−2519
501.60 × 10¹³0.6698−1828−465−2293
258.00 × 10¹²0.5036−1374−465−1839

Table B: Xenon after a Trip Undergraduate

Power before tript (h)ρ_Xe(t) (pcm)Peak time (h)Peak ρ_Xe (pcm)
100%4−38688.7−4358
100%10−4330
100%24−2663
100%48−631
50%10−25107.0−2586

Sample calculation (100%, t = 10 h = 36 000 s): ρ_I0 λ_I/(λ_X − λ_I) = −7770 × (−3.679) = 28 590; ρ_Xe = −2189 × 0.4712 + 28 590 × (0.3559 − 0.4712) = −4330 pcm. With 3000 pcm of excess reactivity, xenon is more negative than −3000 pcm from 1.5 h to 21.5 h after the trip, so a restart is impossible for about 20 hours unless it is made within the first 1.5 hours.

Table C: Fuel Cycle Plans (3411 MWt) Undergraduate

EFPDLoading (tU)BatchesEnergy (MWd)Cycle burnup (MWd/tU)Fissioned (kg)Discharge burnup (MWd/tU)
5008931.706 × 10⁶19 163179157 489
4508931.535 × 10⁶17 247161251 740
3008931.023 × 10⁶11 498107434 493
5007241.706 × 10⁶23 688179194 750 (exceeds limit)

Table D: Restart Window after a Trip Upper undergraduateGraduate step

Power before tripAvailable (pcm)Peak |ρ_Xe| (pcm)Dead time starts (h)Dead time ends (h)Dead time (h)Conservative restart, +10% (h)
100%300043581.521.520.123.5
100%350043582.717.915.220.2
100%400043584.614.09.417.0
75%300034882.915.512.618.0
50%250025864.310.25.913.8
50%200025860.717.216.519.4

Crossing times read from the graph to the nearest 0.1 h. Include a screenshot of one restart-window graph with both crossings marked.

Graduate step: with a +10% xenon uncertainty the conservative restart time is found where |ρ_Xe| = R/1.10. After a full-power trip with 3000 pcm available it moves from 21.5 h to 23.5 h; with 4000 pcm, from 14.0 h to 17.0 h.

Table E: Critical Boron Letdown (α_B = −8 pcm/ppm, 20 pcm lost per EFPD) Upper undergraduateGraduate step

C_BOC (ppm)Clean-core boron (ppm)EFPDCritical boron (ppm)End of cycle (EFPD)Re-forecast EOC, +40 ppm (EFPD)
12001532200700480522
14001732200900560609
14001732400400560583
16001932300850640676

Clean-core boron = C_BOC + 2654/8; C(D) = C_BOC − 2.5D after the poisons settle; D_EOC = C_BOC × 8/20.

Graduate step: a measured boron 40 ppm above the curve (a +320 pcm anomaly, inside the ±1000 pcm limit) means the fuel is losing reactivity more slowly. Re-fitting the rate: at 1400 ppm and 200 EFPD, r = (1400 − 940)/200 = 2.30 ppm/EFPD and the end of cycle moves from 560 to 609 EFPD; the same offset found later (400 EFPD) moves it only to 583 EFPD.

Discussion

Equilibrium xenon rose with power but not in proportion: halving the power from 100% to 50% removed only 17% of the xenon worth, because at high flux burnout, not decay, removes most of the xenon. Samarium was −465 pcm at every power level. Together the poisons held down about 2650 pcm at full power, which the core must carry as excess reactivity in the fresh fuel.

After a trip from full power, xenon doubled to −4358 pcm at 8.7 h, because the I-135 inventory kept producing xenon while burnout had stopped. It then decayed to −631 pcm by 48 h. With 3000 pcm available, the plant would face a dead time of about 20 hours. A trip from 50% gave a much smaller peak (−2586 pcm), because the iodine inventory is proportional to flux while equilibrium xenon is not.

The 500 EFPD, three-batch plan gave a discharge burnup of 57.5 GWd/tU, inside the 62 GWd/tU limit, and fissioned 1.79 tonnes of heavy metal, about 2% of the core. The smaller core with four batches would have discharged fuel at almost 95 GWd/tU and is not licensable; a real plan would shorten the cycle or load more fuel.

The graphs turned these results into operating decisions. On the restart-window graph, raising the available reactivity from 3000 to 4000 pcm shortened the dead time after a full-power trip from 20.1 h to 9.4 h, and after a trip from 50% the dead time was only 5.9 h with 2500 pcm available, because the iodine inventory, and so the xenon peak, is smaller. The boron letdown curve fell by about 332 ppm in the first weeks as xenon and samarium built in, then by 2.5 ppm per EFPD. Starting at 1400 ppm, the boron reached 0 ppm at 560 EFPD, enough for the 500 EFPD plan in Table C; starting at 1200 ppm it would run out at 480 EFPD, so the core would need more fresh fuel or a coastdown.

The graduate steps showed how engineers handle uncertainty and measured data. A ±10% allowance on xenon delayed the planned restart by 2 to 3 hours, because the xenon curve falls slowly near the crossing, so a small error in worth becomes a large error in time. Re-fitting the letdown curve to a measured boron showed that the same 40 ppm offset changes the end-of-cycle forecast by about 50 EFPD early in the cycle but by only about 23 EFPD later, which is why fuel managers update the forecast with every boron measurement.

Conclusion

Xenon worth depends on flux and time, samarium does not, and post-trip xenon can prevent a restart for many hours. Cycle length, core loading, and the number of batches together set the burnup, which must stay within licensing limits.

Practice Questions

Show all work and include units. Use the data table in the Theory section.

Question 1
Find the equilibrium xenon worth at a very high flux (φ ≫ φ_X) and at a very low flux (φ ≪ φ_X). What does each limit mean physically?
Hint: look at φ/(φ + φ_X) in each limit.
Question 2
A reactor runs at 100% and power is reduced to 50%. Explain, without calculating, whether xenon worth first rises or falls and why, and what the operators must do with rods or boron.
Hint: burnout drops at once, but production from iodine continues at the old rate for a while.
Question 3
Use the post-trip equation to find the xenon worth 72 h after a trip from 100% and compare it with the equilibrium value.
Hint: t = 259 200 s.
Question 4
Why does samarium-149 build up after shutdown and stay there, while xenon-135 eventually disappears?
Hint: compare the stability of Sm-149 and Xe-135.
Question 5
A plant runs 480 EFPD per cycle at 3411 MWt with 89 tU and wants 18-month cycles at a 93% capacity factor. How many calendar days is one cycle, and is 480 EFPD consistent with 18 months?
Hint: EFPD = calendar days × capacity factor, before subtracting the refuelling outage.
Question 6: Challenge
The fresh fuel is enriched to 4.5% U-235 in 89 tU. Using your 500 EFPD result, estimate what fraction of the U-235 loaded into one fresh batch (one-third of the core) is consumed over its three cycles, assuming about 70% of the energy comes from U-235. Why is this fraction well below 100%?
Hint: U-235 consumed includes capture as well as fission; the rest of the energy comes from bred plutonium.