Theory: Fission Product Poisons and Fuel Burnup
Why Poisons and Burnup Matter
Fission does not only release energy and neutrons; it leaves behind fission products, and a few of them absorb thermal neutrons so strongly that they act as built-in control rods. The two that matter most are xenon-135 and samarium-149. Their worth changes with power and with time after a power change, so operators must predict them for every startup, power change, and trip. Over a whole cycle the fuel is also used up: U-235 is fissioned, plutonium is bred, and the burnup of each batch sets the cycle length, the refuelling plan, and the fuel cost.
Xenon-135: Production, Burnout, and Decay
Xe-135 has the largest thermal absorption cross section known, about 2.65 × 10⁶ b. About 95% of it comes from the decay of iodine-135 (half-life 6.57 h), which is itself a fission product; the rest is produced directly. At power, xenon is removed in two ways: it decays (half-life 9.14 h), and it absorbs neutrons and becomes Xe-136, which is called burnout. At high flux, burnout dominates, so the equilibrium xenon worth levels off instead of rising in proportion to power. The flux at which burnout equals decay is φ_X = λ_X/σ_X.
φ_X = λ_X / σ_X ρ_Xe,eq = −(γ/ν) × φ / (φ + φ_X)
ρ_Sm,eq = −γ_Pm / ν (independent of flux)
Xenon after a Trip: The Xenon Peak and Dead Time
When the reactor trips, burnout stops instantly, but the large inventory of I-135 in the fuel keeps decaying to xenon. Because iodine decays faster than xenon, xenon builds up for several hours and then decays away. The peak can be roughly twice the equilibrium value. If the excess reactivity available in the core (from rods and boron) is smaller than the extra xenon worth, the reactor cannot be restarted until xenon decays: the xenon dead time. Late in a cycle, when boron is low, this can last a day or more. The same physics drives xenon oscillations in large cores and the xenon "pit" that operators must manage after a power reduction.
ρ_I0 = −(γ_I/ν)(σ_X φ/λ_I) (the iodine inventory expressed as xenon worth)
Samarium-149
Sm-149 (σ ≈ 4.1 × 10⁴ b) is produced from promethium-149 (half-life 53 h) and is stable, so it is removed only by burnout. Its equilibrium worth is the same at every power level. After shutdown, the promethium in the fuel decays to samarium, which builds up and stays; it is removed only when the reactor runs again.
Fuel Burnup and Cycle Length
Burnup is the thermal energy produced per tonne of heavy metal, in megawatt-days per tonne of uranium (MWd/tU) or GWd/tU. About 1.05 g of heavy metal is fissioned for each MWd. A cycle is measured in effective full-power days (EFPD). PWRs refuel one-third or one-quarter of the core at each outage, so each assembly stays for three or four cycles and leaves with a discharge burnup of roughly the number of batches times the cycle burnup. US licensing limits the peak rod burnup to about 62 GWd/tU, which, together with the 5% enrichment limit, sets how long cycles can be.
Uranium fissioned ≈ 1.05 g × P × EFPD Discharge burnup ≈ n_batches × cycle burnup
Operating Graphs: Restart Windows and Boron Letdown
Shift engineers plot the post-trip xenon worth against the reactivity they can add by withdrawing rods and diluting boron. Where the curve rises above that line the reactor cannot be made critical, and the two crossing points mark the start and end of the xenon dead time. Over a whole cycle, the plant tracks the critical boron letdown curve: the soluble boron needed to hold the core critical at full power. It falls quickly at the start of the cycle as xenon and samarium build in, then falls almost linearly as the fuel depletes. The cycle ends when the boron reaches about 0 ppm; after that the plant can only coast down by letting temperature and power fall. Comparing the measured boron with the predicted curve is one of the main checks that the core is behaving as designed.
Data Used in This Lab
| Quantity | Value | Quantity | Value |
|---|---|---|---|
| λ_X (Xe-135, 9.14 h) | 2.09 × 10⁻⁵ s⁻¹ | λ_I (I-135, 6.57 h) | 2.87 × 10⁻⁵ s⁻¹ |
| σ_X (Xe-135, thermal) | 2.65 × 10⁶ b | ν | 2.43 |
| γ_I; γ_X (direct); total γ | 0.0639; 0.0024; 0.0663 | γ_Pm (Pm-149) | 0.0113 |
| Full-power thermal flux | 3.2 × 10¹³ n/cm²·s | Rated power | 3411 MWt |
| Heavy metal fissioned | 1.05 g per MWd | Peak rod burnup limit (US) | 62 000 MWd/tU |
Data follow the DOE Fundamentals Handbook (Nuclear Physics and Reactor Theory, Module 3: Fission Product Poisons), the KAPL Chart of the Nuclides, and IAEA reactor-physics training material. The worth formulas are the simplified handbook forms; plant calculations include f, spatial effects, and the full depletion chains.
Operations
After a trip, the shift calculates xenon and an estimated critical position to decide whether and when a restart is possible.
Load following
Plants that change power for the grid must manage xenon transients and axial xenon oscillations.
Fuel management
Fuel managers choose cycle length, batch size, and enrichment to meet the utility's outage schedule within burnup limits.
Apparatus
The plant tools used to track poisons and burnup. In the simulation these are modelled for you, and the readings correspond to what each would report.
Instructions: Running the Virtual Experiment
You are the reactor engineer responsible for poison predictions and the fuel cycle. The simulation has three immersive 3D work areas and two graph work areas. The parts build from undergraduate work in Parts A to C to graduate-level analysis in the last step of Parts D and E; the level of each part is shown beside its title. In each one you set the conditions, read the instruments, work out the answer yourself, enter it, and press Check. Record every reading and calculation in your lab report tables (modelled in the Example Report), with a labelled screenshot of each setup. Drag in any 3D view to orbit, and scroll to zoom. Use the data table in the Theory section.
Simulation: Poison Monitor, Post-Trip Xenon, Fuel Cycle, and Operating Graphs
The reactor has run steadily long enough for xenon-135 and samarium-149 to reach equilibrium. Full power corresponds to a core-average thermal flux of 3.2 × 10¹³ n/cm²·s, and the flux is proportional to power. Part A uses this work area.
Setup
Readings
The simplified equilibrium worths here assume all thermal absorptions that matter are in the fuel (f ≈ 1), as in the DOE handbook estimate.
Work it out, then check
| Power (%) | φ (n/cm²·s) | φ/(φ + φ_X) | ρ_Xe (pcm) | ρ_Sm (pcm) | Total (pcm) |
|---|
The reactor trips. Fission stops, so no new iodine or xenon is produced, but the iodine-135 already in the fuel keeps decaying to xenon-135, while xenon is no longer burned out by the flux. Part B uses this work area.
Setup
Readings
ρ_I0 is the reactivity the iodine would have if it were all xenon: ρ_I0 = −(γ_I/ν)(σ_Xφ/λ_I), with γ_I = 0.0639.
Work it out, then check
| Power before trip | t (h) | ρ_Xe(t) (pcm) | Peak time (h) | Peak ρ_Xe (pcm) |
|---|
A 3411 MWt core is refuelled in batches: at each outage the most-burned batch is discharged and replaced with fresh fuel. Run a cycle and work out the burnup. Part C uses this work area.
Setup
Readings
About 1.05 g of uranium (mostly U-235, plus plutonium bred from U-238) is fissioned for every megawatt-day of heat.
Work it out, then check
| EFPD | Loading (tU) | Batches | Energy (MWd) | Cycle burnup (MWd/tU) | Fissioned (kg) | Discharge burnup (MWd/tU) |
|---|
After a trip the operators must decide when the reactor can be restarted. The reactivity they can add by withdrawing rods and diluting boron is limited, so while xenon is more negative than that amount, a restart is impossible. Part D uses this work area.
Setup
Readings
A restart is impossible while |ρ_Xe(t)| is greater than the reactivity available. Read the crossing times from the graph or the data table; ρ_Xe(t) uses the same post-trip equation as Part B.
Work it out, then check
| Power before trip | Available (pcm) | Peak |ρ_Xe| (pcm) | Dead time starts (h) | Dead time ends (h) | Dead time (h) | Advanced: conservative restart (h) |
|---|
Through a cycle, soluble boron is diluted to make up for the reactivity the fuel loses as it burns. The critical boron letdown curve is the plant's main check that the core is behaving as designed. Part E uses this work area.
Setup
Readings
C(D) = C_BOC − (20/8) D once xenon and samarium are at equilibrium (after about 30 EFPD). Simplified training model; real curves are flattened early in the cycle by burnable absorbers.
Work it out, then check
| C_BOC (ppm) | Clean-core boron (ppm) | EFPD | Critical boron (ppm) | End of cycle (EFPD) | Advanced: re-forecast EOC (EFPD) |
|---|
This accessible version provides the same set-up, work-out, and check exercises as the 3D and graph work areas, using native controls, data tables, and screen-reader announcements.
Team Questions
Example Lab Report
Sample report showing the expected format and level of detail. Use it as a guide for your own submission, and include labelled screenshots of each setup.
Fission Product Poisons and Fuel Burnup: Xenon, Samarium, and Cycle Length
Nuclear Engineering Technology | Section: [Your Section] | Date: [Date]
Lab Members: [Names of all members present]
Purpose
To calculate equilibrium xenon and samarium worth at different power levels; to predict the xenon transient after a trip, including the peak and the restart dead time; to calculate cycle burnup, uranium fissioned, and discharge burnup for several fuel-cycle plans; and to read restart windows and a critical boron letdown curve from operating graphs.
Theory
At equilibrium, ρ_Xe = −(γ/ν)φ/(φ + φ_X) with φ_X = λ_X/σ_X, and ρ_Sm = −γ_Pm/ν. After a trip, ρ_Xe(t) = ρ_X0e^(−λ_X t) + ρ_I0[λ_I/(λ_X − λ_I)](e^(−λ_I t) − e^(−λ_X t)). Burnup is P × EFPD / M_U, with about 1.05 g fissioned per MWd.
Table A: Equilibrium Poisons (φ_X = 7.887 × 10¹² n/cm²·s) Undergraduate
| Power (%) | φ (n/cm²·s) | φ/(φ + φ_X) | ρ_Xe (pcm) | ρ_Sm (pcm) | Total (pcm) |
|---|---|---|---|---|---|
| 100 | 3.20 × 10¹³ | 0.8023 | −2189 | −465 | −2654 |
| 75 | 2.40 × 10¹³ | 0.7527 | −2054 | −465 | −2519 |
| 50 | 1.60 × 10¹³ | 0.6698 | −1828 | −465 | −2293 |
| 25 | 8.00 × 10¹² | 0.5036 | −1374 | −465 | −1839 |
Table B: Xenon after a Trip Undergraduate
| Power before trip | t (h) | ρ_Xe(t) (pcm) | Peak time (h) | Peak ρ_Xe (pcm) |
|---|---|---|---|---|
| 100% | 4 | −3868 | 8.7 | −4358 |
| 100% | 10 | −4330 | ||
| 100% | 24 | −2663 | ||
| 100% | 48 | −631 | ||
| 50% | 10 | −2510 | 7.0 | −2586 |
Sample calculation (100%, t = 10 h = 36 000 s): ρ_I0 λ_I/(λ_X − λ_I) = −7770 × (−3.679) = 28 590; ρ_Xe = −2189 × 0.4712 + 28 590 × (0.3559 − 0.4712) = −4330 pcm. With 3000 pcm of excess reactivity, xenon is more negative than −3000 pcm from 1.5 h to 21.5 h after the trip, so a restart is impossible for about 20 hours unless it is made within the first 1.5 hours.
Table C: Fuel Cycle Plans (3411 MWt) Undergraduate
| EFPD | Loading (tU) | Batches | Energy (MWd) | Cycle burnup (MWd/tU) | Fissioned (kg) | Discharge burnup (MWd/tU) |
|---|---|---|---|---|---|---|
| 500 | 89 | 3 | 1.706 × 10⁶ | 19 163 | 1791 | 57 489 |
| 450 | 89 | 3 | 1.535 × 10⁶ | 17 247 | 1612 | 51 740 |
| 300 | 89 | 3 | 1.023 × 10⁶ | 11 498 | 1074 | 34 493 |
| 500 | 72 | 4 | 1.706 × 10⁶ | 23 688 | 1791 | 94 750 (exceeds limit) |
Table D: Restart Window after a Trip Upper undergraduateGraduate step
| Power before trip | Available (pcm) | Peak |ρ_Xe| (pcm) | Dead time starts (h) | Dead time ends (h) | Dead time (h) | Conservative restart, +10% (h) |
|---|---|---|---|---|---|---|
| 100% | 3000 | 4358 | 1.5 | 21.5 | 20.1 | 23.5 |
| 100% | 3500 | 4358 | 2.7 | 17.9 | 15.2 | 20.2 |
| 100% | 4000 | 4358 | 4.6 | 14.0 | 9.4 | 17.0 |
| 75% | 3000 | 3488 | 2.9 | 15.5 | 12.6 | 18.0 |
| 50% | 2500 | 2586 | 4.3 | 10.2 | 5.9 | 13.8 |
| 50% | 2000 | 2586 | 0.7 | 17.2 | 16.5 | 19.4 |
Crossing times read from the graph to the nearest 0.1 h. Include a screenshot of one restart-window graph with both crossings marked.
Graduate step: with a +10% xenon uncertainty the conservative restart time is found where |ρ_Xe| = R/1.10. After a full-power trip with 3000 pcm available it moves from 21.5 h to 23.5 h; with 4000 pcm, from 14.0 h to 17.0 h.
Table E: Critical Boron Letdown (α_B = −8 pcm/ppm, 20 pcm lost per EFPD) Upper undergraduateGraduate step
| C_BOC (ppm) | Clean-core boron (ppm) | EFPD | Critical boron (ppm) | End of cycle (EFPD) | Re-forecast EOC, +40 ppm (EFPD) |
|---|---|---|---|---|---|
| 1200 | 1532 | 200 | 700 | 480 | 522 |
| 1400 | 1732 | 200 | 900 | 560 | 609 |
| 1400 | 1732 | 400 | 400 | 560 | 583 |
| 1600 | 1932 | 300 | 850 | 640 | 676 |
Clean-core boron = C_BOC + 2654/8; C(D) = C_BOC − 2.5D after the poisons settle; D_EOC = C_BOC × 8/20.
Graduate step: a measured boron 40 ppm above the curve (a +320 pcm anomaly, inside the ±1000 pcm limit) means the fuel is losing reactivity more slowly. Re-fitting the rate: at 1400 ppm and 200 EFPD, r = (1400 − 940)/200 = 2.30 ppm/EFPD and the end of cycle moves from 560 to 609 EFPD; the same offset found later (400 EFPD) moves it only to 583 EFPD.
Discussion
Equilibrium xenon rose with power but not in proportion: halving the power from 100% to 50% removed only 17% of the xenon worth, because at high flux burnout, not decay, removes most of the xenon. Samarium was −465 pcm at every power level. Together the poisons held down about 2650 pcm at full power, which the core must carry as excess reactivity in the fresh fuel.
After a trip from full power, xenon doubled to −4358 pcm at 8.7 h, because the I-135 inventory kept producing xenon while burnout had stopped. It then decayed to −631 pcm by 48 h. With 3000 pcm available, the plant would face a dead time of about 20 hours. A trip from 50% gave a much smaller peak (−2586 pcm), because the iodine inventory is proportional to flux while equilibrium xenon is not.
The 500 EFPD, three-batch plan gave a discharge burnup of 57.5 GWd/tU, inside the 62 GWd/tU limit, and fissioned 1.79 tonnes of heavy metal, about 2% of the core. The smaller core with four batches would have discharged fuel at almost 95 GWd/tU and is not licensable; a real plan would shorten the cycle or load more fuel.
The graphs turned these results into operating decisions. On the restart-window graph, raising the available reactivity from 3000 to 4000 pcm shortened the dead time after a full-power trip from 20.1 h to 9.4 h, and after a trip from 50% the dead time was only 5.9 h with 2500 pcm available, because the iodine inventory, and so the xenon peak, is smaller. The boron letdown curve fell by about 332 ppm in the first weeks as xenon and samarium built in, then by 2.5 ppm per EFPD. Starting at 1400 ppm, the boron reached 0 ppm at 560 EFPD, enough for the 500 EFPD plan in Table C; starting at 1200 ppm it would run out at 480 EFPD, so the core would need more fresh fuel or a coastdown.
The graduate steps showed how engineers handle uncertainty and measured data. A ±10% allowance on xenon delayed the planned restart by 2 to 3 hours, because the xenon curve falls slowly near the crossing, so a small error in worth becomes a large error in time. Re-fitting the letdown curve to a measured boron showed that the same 40 ppm offset changes the end-of-cycle forecast by about 50 EFPD early in the cycle but by only about 23 EFPD later, which is why fuel managers update the forecast with every boron measurement.
Conclusion
Xenon worth depends on flux and time, samarium does not, and post-trip xenon can prevent a restart for many hours. Cycle length, core loading, and the number of batches together set the burnup, which must stay within licensing limits.
Practice Questions
Show all work and include units. Use the data table in the Theory section.